Two-column Sequential Injection Chromatography-New approach for fast and effective analysis and its comparison with gradient elution chromatography

被引:20
作者
Chocholous, Petr [1 ]
Satinsky, Dalibor [1 ]
Sklenarova, Hana [1 ]
Solich, Petr [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, Fac Pharm, Hradec Kralove 50005, Czech Republic
关键词
Sequential injection chromatography; Two-column chromatography; Monolithic column; Paracetamol; Caffeine; Propyphenazone; PHASE LIQUID-CHROMATOGRAPHY; MONOLITHIC COLUMN; LOSARTAN POTASSIUM; PERFORMANCE; COSMETICS; SYSTEM; HYDROCHLOROTHIAZIDE; ANTIOXIDANTS; SEPARATION; TABLETS;
D O I
10.1016/j.aca.2010.01.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents novel approach in low-pressure chromatography flow systems two-column Sequential Injection Chromatography (2-C SIC) and its comparison with gradient elution chromatography on the same instrument. The system was equipped with two different chromatographic columns (connected to selection valve in parallel design) for isocratic separation and determination of all components in composed anti-inflammatory pharmaceutical preparation (tablets). The sample was first injected on the first column of length 30 mm where less retained analytes were separated and then the sample was injected on the second column of length 10 mm where more retained analytes were separated. The SIC system was based on a commercial SIChrom(TM) manifold (8-port high-pressure selection valve and medium-pressure syringe pump with 4 mL reservoir) (FIAlab(R), USA) with two commercially available monolithic columns the "first column" Chromolith(R) Flash RP-18e (25 mm x 4.6 mm id. with guard column 5 mm x 4.6 mm i.d.) and the "second column" Chromolith(R) RP-18e (10 mm x 4.6 mm id.) and CCD UV-vis detector USB 4000 with micro-volume 1.0 cm Z flow cell. Two mobile phases were used for analysis (one for each column). The mobile phase 1 used for elution of paracetamol, caffeine and salicylic acid (internal standard) was acetonitrile/water (10:90, v/v, the water part of pH 3.5 adjusted with acetic acid), flow rate was 0.9 mL min(-1) (volume 3.0 mL of mobile phase per analysis). The mobile phase 2 used for elution of propyphenazone was acetonitrile/water (30:70, v/v); flow rate was 1.2 mL min(-1) (volume 1.5 mL of mobile phase per analysis). Absorbance was monitored at 210 nm. Samples were prepared by dissolving of one tablet in 30% acetonitrile and 10 mu L of filtered supernatant was injected on each column (2 x 10 mu L). The chromatographic resolution between all compounds was >1.45 and analysis time was 5.5 min under the optimal conditions. Limits of detection were determined at 0.4 mu g mL(-1) for paracetamol, at 0.5 mu g mL(-1) for caffeine and at 0.7 mu g mL(-1) for propyphenazone. The new two-column chromatographic set-up developed as an alternative approach to gradient elution chromatography shows evident advantages (time and solvent reduction more than one-third) as compared with single-column gradient SIC method with Chromolith(R) Flash RP-18 (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 23 条
[11]   Development of a new high performance low pressure chromatographic system using a multisyringe burette coupled to a chromatographic monolithic column [J].
Gonzalez-San Miguel, Hilda M. ;
Alpizar-Lorenzo, Jesus M. ;
Cerda-Martin, Victor .
TALANTA, 2007, 72 (01) :296-300
[12]   Heterogeneity of the surface energy on unused C18-chromolith adsorbents in reversed-phase liquid chromatography [J].
Gritti, F ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1028 (01) :105-119
[13]   FUNDAMENTALS OF SINUSOIDAL FLOW SEQUENTIAL INJECTION SPECTROPHOTOMETRY [J].
GUBELI, T ;
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2407-2413
[14]   Simultaneous determination of β-lactamic antibiotics by a new high-performance low-pressure chromatographic system using a multisyringe burette coupled to a monolithic column (MSC) [J].
Miguel, Hilda M. Gonzalezz-San ;
Alpizar-Lorenzo, Jesus M. ;
Cerda, Victor .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (02) :663-671
[15]   Effect of skeleton size on the performance of octadecylsilylated continuous porous silica columns in reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :135-146
[16]   Implementing stepwise solvent elution in sequential injection chromatography for fluorimetric determination of intracellular free amino acids in the microalgae Tetraselmis gracilis [J].
Rigobello-Masini, Marilda ;
Penteado, Jose C. P. ;
Liria, Cleber W. ;
Miranda, M. Teresa M. ;
Masini, Jorge C. .
ANALYTICA CHIMICA ACTA, 2008, 628 (02) :123-132
[17]   SEQUENTIAL INJECTION - A NEW CONCEPT FOR CHEMICAL SENSORS, PROCESS ANALYSIS AND LABORATORY ASSAYS [J].
RUZICKA, J ;
MARSHALL, GD .
ANALYTICA CHIMICA ACTA, 1990, 237 (02) :329-343
[18]   Sequential injection chromatographic determination of paracetamol, caffeine, and acetylsalicylic acid in pharmaceutical tablets [J].
Satínsky, D ;
Neto, I ;
Solich, P ;
Sklenárová, H ;
Conceiçao, M ;
Montenegro, BSM ;
Araújo, AN .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (7-8) :529-536
[19]   Monolithic columns -: a new concept of separation in the sequential injection technique [J].
Satínsky, D ;
Solich, P ;
Chocholous, P ;
Karlícek, R .
ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) :205-214
[20]   GRADIENT ELUTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. THEORETICAL BASIS FOR REVERSED-PHASE SYSTEMS [J].
SNYDER, LR ;
DOLAN, JW ;
GANT, JR .
JOURNAL OF CHROMATOGRAPHY, 1979, 165 (01) :3-30