Reversible, fluorescence-based optical sensor for hydrogen peroxide

被引:27
|
作者
Mills, Andrew
Tommons, Cheryl
Bailey, Raymond T.
Tedford, M. Catriona
Crilly, Peter J.
机构
[1] Univ Strathclyde, Dept Pure & Appl Chem, WestCHEM, Glasgow G1 1XL, Lanark, Scotland
[2] Bell Coll Technol, Hamilton ML3 0JB, Lanark, Scotland
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1039/b618506a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preparation and characterisation are described of a robust, reversible, hydrogen peroxide optical sensor, based on the fluorescent quenching of the dye ion-pair [Ru(bpy)(3)(2+)(Ph4B-)(2)], by O-2 produced by the catalytic breakdown of H2O2, utilizing the inorganic catalyst RuO2 center dot xH(2)O. The main feature of this system is the one-pot formulation of a coating ink that, when dried, forms an active single-layer fluorescence-based H2O2 sensor, demonstrably capable of detecting H2O2 over the range of 0.01 to 1 M, with a relative standard deviation of ca. 4% and a calculated lower limit of detection of 0.1 mM. These sensors are sterilisable, using dry-heat, and stable when stored over 40 days, without exhibiting any loss in sensitivity or response characteristics.
引用
收藏
页码:566 / 571
页数:6
相关论文
共 50 条
  • [31] Optical Hydrogen Sulfide Gas Sensor Based on the Fluorescence Quenching of ZnCeS
    Yang Xiao-zhan
    Lei Yong
    Xiao Hu
    Feng Wen-lin
    ACTA PHOTONICA SINICA, 2018, 47 (10)
  • [32] Fluorescence Ratiometric Sensor for Trace Vapor Detection of Hydrogen Peroxide
    Xu, Miao
    Han, Ji-Min
    Wang, Chen
    Yang, Xiaomei
    Pei, Jian
    Zang, Ling
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (11) : 8708 - 8714
  • [33] A fluorescence-based optical fiber analyzer for catecholamine determination
    Silva, Lurdes
    Duarte, Katia
    Freitas, Ana Cristina
    Panteleitchouk, Teresa S. L.
    Rocha-Santos, Teresa A. P.
    Pereira, Maria E.
    Duarte, Armando Costa
    ANALYTICAL METHODS, 2012, 4 (08) : 2300 - 2306
  • [34] Dirhodium tetracarboxylate scaffolds as reversible fluorescence-based nitric oxide sensors
    Hilderbrand, SA
    Lim, MH
    Lippard, SJ
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (15) : 4972 - 4978
  • [35] Development of optical phantoms for use in fluorescence-based imaging
    Noiseux, Isabelle
    Fortin, Michel
    Leclair, Sebastien
    Osouf, Jocelyne
    Mermut, Ozzy
    DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE II, 2010, 7567
  • [36] Reversible Optical Sensor Membrane for Hydrogen Peroxide Using an Immobilized Fluorescent Probe, and its Application to a Glucose Biosensor
    Otto S. Wolfbeis
    Michael Schäferling
    Axel Dürkop
    Microchimica Acta, 2003, 143 : 221 - 227
  • [37] MONITORING THE COMPOSITE CURING PROCESS WITH A FLUORESCENCE-BASED FIBEROPTIC SENSOR
    LEVY, RL
    SCHWAB, SD
    POLYMER COMPOSITES, 1991, 12 (02) : 96 - 101
  • [38] Reversible optical sensor membrane for hydrogen peroxide using an immobilized fluorescent probe, and its application to a glucose biosensor
    Wolfbeis, OS
    Schäferling, M
    Dürkop, A
    MICROCHIMICA ACTA, 2003, 143 (04) : 221 - 227
  • [39] Development of a Fluorescence-Based Sensor for Rapid Diagnosis of Cyanide Exposure
    Jackson, Randy
    Oda, Robert P.
    Bhandari, Raj K.
    Mahon, Sari B.
    Brenner, Matthew
    Rockwood, Gary A.
    Logue, Brian A.
    ANALYTICAL CHEMISTRY, 2014, 86 (03) : 1845 - 1852
  • [40] A Fluorescence-Based Chemical Sensor for Detection of Melamine in Aqueous Solutions
    Radha, Remya
    Vitor, Rute F.
    Al-Sayah, Mohammad Hussein
    CHEMOSENSORS, 2022, 10 (01)