Application of cast magnetic attachments to sectional complete dentures for a patient with microstomia: A clinical report

被引:26
作者
Watanabe, I
Tanaka, Y
Ohkubo, C
Miller, AW
机构
[1] Texas A&M Univ Syst, Hlth Sci Ctr, Dept Biomat Sci, Baylor Coll Dent, Dallas, TX 75246 USA
[2] Nagasaki Univ, Sch Dent, Nagasaki 852, Japan
[3] Tsurumi Univ, Sch Dent Med, Yokohama, Kanagawa, Japan
关键词
D O I
10.1067/mpr.2002.130095
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Patients with microstomia who must wear removable dental prostheses often state that they are unable to insert or remove the prosthesis because of the constricted opening of the oral cavity. This article presents a cast iron-platinum magnetic attachment system applied to sectional collapsed complete dentures for an edentulous patient with microstomia. With the use of lingual and palatal midline hinges and a cast iron-platinum magnetic attachment, the sectional prosthesis was successfully and easily inserted and provided adequate function in the patient's mouth.
引用
收藏
页码:573 / 577
页数:5
相关论文
共 12 条
[1]   PROSTHETIC RESTORATION IN MICROSTOMIA [J].
CONROY, B ;
REITZIK, M .
JOURNAL OF PROSTHETIC DENTISTRY, 1971, 26 (03) :324-&
[2]   Magnetically connected removable sectional denture for a maxillary defect with severe undercut: A clinical report [J].
Matsumura, H ;
Kawasaki, K .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (01) :22-26
[3]  
MCCORD JF, 1989, J PROSTHET DENT, V61, P645
[4]   STUDIES ON LASER-WELDED AND PLASMA-WELDED TITANIUM [J].
ROGGENSACK, M ;
WALTER, MH ;
BONING, KW .
DENTAL MATERIALS, 1993, 9 (02) :104-107
[5]  
SMITH PG, 1982, ARCH OTOLARYNGOL, V108, P714
[6]   Sectional collapsed denture for a partially edentulous patient with microstomia: A clinical report [J].
Suzuki, Y ;
Abe, M ;
Hosoi, T ;
Kurtz, KS .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (03) :256-259
[7]   Microstructures and magnetic properties of Fe-Pt permanent magnets [J].
Tanaka, Y ;
Kimura, N ;
Hono, K ;
Yasuda, K ;
Sakurai, T .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1997, 170 (03) :289-297
[8]   THE MANDIBULAR SWING-LOCK COMPLETE DENTURE FOR PATIENTS WITH MICROSTOMIA [J].
WAHLE, JJ ;
GARDNER, LK ;
FIEBIGER, M .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (03) :523-527
[9]   Attractive force of castable iron-platinum magnetic alloys [J].
Watanabe, I ;
Tanaka, Y ;
Fukunaga, H ;
Hisatsune, K ;
Atsuta, M .
DENTAL MATERIALS, 2001, 17 (03) :197-200
[10]   In vitro corrosion behavior of cast iron-platinum magnetic alloys [J].
Watanabe, I ;
Hai, K ;
Tanaka, Y ;
Hisatsune, K ;
Atsuta, M .
DENTAL MATERIALS, 2001, 17 (03) :217-220