Accuracy of sonographically guided 14-gauge core-needle biopsy: Results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions

被引:91
作者
Crystal, P
Koretz, M
Shcharynsky, S
Makarov, V
Strano, S
机构
[1] Ben Gurion Univ Negev, Fac Hlth Sci, Soroka Univ Med Ctr, Dept Radiol, IL-84105 Beer Sheva, Israel
[2] Ben Gurion Univ Negev, Fac Hlth Sci, Soroka Univ Med Ctr, Comprehens Breast Ctr, IL-84105 Beer Sheva, Israel
关键词
core-needle biopsy; breast neoplasm; breast ultrasonography; ultrasound-guided biopsy;
D O I
10.1002/jcu.20089
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose. The objective of this study was to examine the diagnostic accuracy of sonographically guided 14-gauge core-needle biopsy (CNB). Methods. Sonographically guided 14-gauge CNBs of 715 breast lesions were performed in 652 patients. Histopathologic results were correlated with imaging findings, and repeat biopsy was recommended in the cases of discordance between the radiologic and pathologic results. Long-term follow-up was used for patients with CNB findings of a benign lesion. Results. Sonographically guided CNB revealed malignancy in 311 lesions (43%). Thirty-one lesions with CNB findings indicating benign conditions underwent additional image-guided or excisional biopsy because of indeterminate pathologic features, disagreement between radiologic and pathologic results, surgeon preference, or patient request. Within these 31 cases, 9 malignancies were diagnosed. The duration of follow-up for the remaining 373 benign lesions varied from 27 to 60 months. In 3 of these 373 cases, carcinoma was diagnosed at the site of CNB. The false-negative rate of 14-gauge sonographically guided CNB was 3.7%, and the sensitivity of sonographically guided CNB for the diagnosis of breast cancer was 96.3%. Conclusions. Sonographically guided 14-gauge CNB is a safe and accurate method for evaluating breast lesions that require tissue sampling. Radiologic-athologic correlation and follow-up of benign lesions are essential for a successful breast biopsy program. (C) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 43 条
  • [1] Follow-up of benign results of stereotactic core breast biopsy
    Adler, DD
    Light, RJ
    Granstrom, P
    Hunter, TB
    Hunt, KR
    [J]. ACADEMIC RADIOLOGY, 2000, 7 (04) : 248 - 253
  • [2] Boerner S, 1999, CANCER CYTOPATHOL, V87, P19, DOI 10.1002/(SICI)1097-0142(19990225)87:1<19::AID-CNCR4>3.0.CO
  • [3] 2-K
  • [4] Stereotactic core-needle breast biopsy: A multi-institutional prospective trial
    Brenner, RJ
    Bassett, LW
    Fajardo, LL
    Dershaw, DD
    Evans, WP
    Hunt, R
    Lee, C
    Tocino, I
    Fisher, P
    McCombs, M
    Jackson, VP
    Feig, SA
    Mendelson, EB
    Margolin, FR
    Bird, R
    Sayre, J
    [J]. RADIOLOGY, 2001, 218 (03) : 866 - 872
  • [5] Buchberger W, 2002, RADIOLOGE, V42, P25, DOI 10.1007/s117-002-8113-9
  • [6] Stereotactic core-needle breast biopsy by surgeons - Minimum 2-year follow-up of benign lesions
    Burns, RP
    Brown, JP
    Roe, SM
    Sprouse, LR
    Yancey, AE
    Witherspoon, LE
    [J]. ANNALS OF SURGERY, 2000, 232 (04) : 542 - 547
  • [7] Needle choice for sonographically guided core biopsy.
    Cardenosa, G
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (03) : 845 - 846
  • [8] US-guided core-needle biopsy of the breast: How many specimens are necessary
    Fishman, JE
    Milikowski, C
    Ramsinghani, R
    Velasquez, MV
    Aviram, G
    [J]. RADIOLOGY, 2003, 226 (03) : 779 - 782
  • [9] Fornage BD, 1999, J CLIN ULTRASOUND, V27, P385, DOI 10.1002/(SICI)1097-0096(199909)27:7<385::AID-JCU5>3.3.CO
  • [10] 2-F