Energy dispersive X-ray fluorescence determination of cadmium in uranium matrix using Cd Kα line excited by continuum

被引:9
|
作者
Dhara, Sangita [1 ]
Misra, N. L. [1 ]
Aggarwal, S. K. [1 ]
Venugopal, V. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Fuel Chem, Bombay 400085, Maharashtra, India
关键词
EDXRF; Cadmium; Uranium; Nuclear reactor; Trace element; IMPURITIES; THORIUM; LEAD;
D O I
10.1016/j.sab.2010.02.012
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
An energy dispersive X-ray fluorescence method for determination of cadmium (Cd) in uranium (U) matrix using continuum source of excitation was developed. Calibration and sample solutions of cadmium, with and without uranium were prepared by mixing different volumes of standard solutions of cadmium and uranyl nitrate, both prepared in suprapure nitric acid. The concentration of Cd in calibration solutions and samples was in the range of 6 to 90 mu g/mL whereas the concentration of Cd with respect to U ranged from 90 to 700 mu g/g of U. From the calibration solutions and samples containing uranium, the major matrix uranium was selectively extracted using 30% tri-n-butyl phosphate in dodecane. Fixed volumes (1.5 mL) of aqueous phases thus obtained were taken directly in specially designed in-house fabricated leak proof Perspex sample cells for the energy dispersive X-ray fluorescence measurements and calibration plots were made by plotting Cd Km intensity against respective Cd concentration. For the calibration solutions not having uranium, the energy dispersive X-ray fluorescence spectra were measured without any extraction and Cd calibration plots were made accordingly. The results obtained showed a precision of 2% (1 sigma) and the results deviated from the expected values by <4% on average. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 50 条
  • [21] Determination of plutonium in nitric acid solutions using energy dispersive L X-ray fluorescence with a low power X-ray generator
    Py, J.
    Groetz, J. -E.
    Hubinois, J. -C.
    Cardona, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 780 : 131 - 137
  • [22] Determination of Nickel and Manganese Contaminants in Pharmaceutical Iron Supplements Using Energy Dispersive X-ray Fluorescence
    Cardoso, Pedro
    Amaro, Pedro
    Santos, Jose Paulo
    de Assis, Joaquim T.
    Carvalho, Maria Luisa
    APPLIED SPECTROSCOPY, 2017, 71 (03) : 432 - 437
  • [23] Determination of multi-element profiles of soil using energy dispersive X-ray fluorescence (EDXRF)
    Yu, KN
    Yeung, ZLL
    Lee, LYL
    Stokes, MJ
    Kwok, RCW
    APPLIED RADIATION AND ISOTOPES, 2002, 57 (02) : 279 - 284
  • [24] Direct determination of uranium in sintered deeply depleted uranium oxide pellets by wavelength dispersive X-ray fluorescence spectrometry
    Pandey, A.
    Dhara, S.
    Khan, F. A.
    Kelkar, A.
    Yadav, R.
    Kumar, Pradeep
    Sathe, D. B.
    Bhatt, R. B.
    Behere, P. G.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 323 (01) : 275 - 281
  • [25] Determination of trace uranium concentrations in spent-fuel reprocessing using online graphite crystal pre-diffraction energy-dispersive x-ray fluorescence
    Fang, Yingtong
    Zhang, Zhaoqing
    Hou, Liudong
    Wang, Zhiqiang
    Zhao, Yaping
    Liu, Quanwei
    Liu, Siwei
    Chang, Xianlong
    Qin, Yongquan
    Ma, Jing
    X-RAY SPECTROMETRY, 2024,
  • [26] Determination of uranium in water samples by energy-dispersive X-ray fluorescence spectrometry after solid-phase extraction
    Carvalho, Roberta N. C. S.
    Anunciacao, Taiana A.
    Dantas, Alailson F.
    Dias, Fabio de S.
    Teixeira, Leonardo S. G.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2024, 21 (10) : 2635 - 2642
  • [27] Uranium determination in seawater by total reflection X-ray fluorescence spectrometry
    Misra, N. L.
    Dhara, S.
    Mudher, K. D. Singh
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (10-11) : 1166 - 1169
  • [28] DETERMINATION OF CADMIUM, CHROMIUM, LEAD, AND MERCURY IN POLYETHYLENE AND POLYPROPYLENE AFTER XYLENE TREATMENT BY ENERGY DISPERSIVE X-RAY FLUORESCENCE SPECTROMETRY
    Ozer, Elif Tumay
    Cimenoglu, M. Akif
    Gucer, Seref
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2011, 39 (04) : 357 - 367
  • [29] Elemental analysis of potteries using energy dispersive X-ray fluorescence technique
    Kumar, A
    Garg, ML
    Singh, N
    Vijayan, V
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2006, 44 (04) : 300 - 307
  • [30] Gaseous detectors for energy dispersive X-ray fluorescence analysis
    Veloso, J. F. C. A.
    Silva, A. L. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 24 - 39