Energy dispersive X-ray fluorescence determination of cadmium in uranium matrix using Cd Kα line excited by continuum

被引:9
|
作者
Dhara, Sangita [1 ]
Misra, N. L. [1 ]
Aggarwal, S. K. [1 ]
Venugopal, V. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Fuel Chem, Bombay 400085, Maharashtra, India
关键词
EDXRF; Cadmium; Uranium; Nuclear reactor; Trace element; IMPURITIES; THORIUM; LEAD;
D O I
10.1016/j.sab.2010.02.012
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
An energy dispersive X-ray fluorescence method for determination of cadmium (Cd) in uranium (U) matrix using continuum source of excitation was developed. Calibration and sample solutions of cadmium, with and without uranium were prepared by mixing different volumes of standard solutions of cadmium and uranyl nitrate, both prepared in suprapure nitric acid. The concentration of Cd in calibration solutions and samples was in the range of 6 to 90 mu g/mL whereas the concentration of Cd with respect to U ranged from 90 to 700 mu g/g of U. From the calibration solutions and samples containing uranium, the major matrix uranium was selectively extracted using 30% tri-n-butyl phosphate in dodecane. Fixed volumes (1.5 mL) of aqueous phases thus obtained were taken directly in specially designed in-house fabricated leak proof Perspex sample cells for the energy dispersive X-ray fluorescence measurements and calibration plots were made by plotting Cd Km intensity against respective Cd concentration. For the calibration solutions not having uranium, the energy dispersive X-ray fluorescence spectra were measured without any extraction and Cd calibration plots were made accordingly. The results obtained showed a precision of 2% (1 sigma) and the results deviated from the expected values by <4% on average. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 50 条
  • [1] Energy dispersive X-ray fluorescence determination of uranium in different uranates using Rh Kα scattered peaks for matrix correction
    Kumar, Sanjay
    Dhara, Sangita
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 193
  • [2] Determination of iron in uranium matrix using energy dispersive X-ray fluorescence (EDXRF) technique
    Biswas, Sujoy
    Rupawate, V. H.
    Hareendran, K. N.
    Roy, S. B.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 306 (02) : 543 - 548
  • [3] Determination of iron in uranium matrix using energy dispersive X-ray fluorescence (EDXRF) technique
    Sujoy Biswas
    V. H. Rupawate
    K. N. Hareendran
    S. B. Roy
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 306 : 543 - 548
  • [4] Determination of uranium and thorium in zircon by energy dispersive X-ray fluorescence technique
    Natarajan, V.
    Porwal, N. K.
    Godbole, S. V.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2012, 19 (06) : 399 - 402
  • [5] Trace element determinations in uranium by energy dispersive X-ray fluorescence spectrometry using thin film specimens
    Sanyal, Kaushik
    Misra, N. L.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 155 : 44 - 49
  • [6] Determination of sulphur in uranium matrix by total reflection X-ray fluorescence spectrometry
    Dhara, Sangita
    Misra, N. L.
    Aggarwal, S. K.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (12) : 1395 - 1398
  • [7] Measurements of the K X-ray intensity ratios by using energy-dispersive X-ray fluorescence spectrometry
    Guerol, A.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (03) : 372 - 376
  • [8] Energy dispersive X-Ray fluorescence determination acid of thorium in phosphoric solutions
    Mirashi, N. N.
    Dhara, Sangita
    Kumar, S. Sanjay
    Chaudhury, Satyajeet
    Misra, N. L.
    Aggarwal, S. K.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (07) : 579 - 582
  • [9] DETERMINATION OF Mn AND Zn IN RICE BY ENERGY DISPERSIVE X-RAY FLUORESCENCE SPECTROMETRY
    Teixeira, Alete Paixao
    Quintella, Cristina M.
    Andrade Korn, Maria das Gracas
    Fernandes, Andrea P.
    Castro, Martha T. P. O.
    QUIMICA NOVA, 2012, 35 (06): : 1133 - 1136
  • [10] Determination of arsenic in contaminated waters using energy dispersive X-ray fluorescence.
    Pataca, LCM
    Bortoleto, GG
    Bueno, MIMS
    QUIMICA NOVA, 2005, 28 (04): : 579 - 582