Exoskeleton-assisted walking improves pulmonary function and walking parameters among individuals with spinal cord injury: a randomized controlled pilot study

被引:28
|
作者
Xiang, Xiao-Na [1 ,2 ,3 ]
Zong, Hui-Yan [1 ]
Ou, Yi [1 ]
Yu, Xi [1 ,2 ]
Cheng, Hong [4 ]
Du, Chun-Ping [1 ]
He, Hong-Chen [1 ,2 ,3 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Rehabil Med, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, Sch Rehabil Sci, West China Sch Med, Chengdu 610041, Sichuan, Peoples R China
[3] Sichuan Univ, West China Hosp, Key Lab Rehabil Med Sichuan Prov, Chengdu 610041, Sichuan, Peoples R China
[4] Univ Elect Sci & Technol China, Chengdu 611731, Sichuan, Peoples R China
基金
国家重点研发计划;
关键词
Spinal cord; Pulmonary; Exercise; Exoskeleton; 6MWT; Rehabilitation; TRUNK MUSCLE-ACTIVITY; EXERCISE; PEOPLE; AMBULATION; STABILITY; CAPACITY; ROBOT;
D O I
10.1186/s12984-021-00880-w
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Exoskeleton-assisted walking (EAW) is expected to improve the gait of spinal cord injury (SCI) individuals. However, few studies reported the changes of pulmonary function (PF) parameters after EAW trainings. Hence, we aimed to explore the effect of EAW on PF parameters, 6-min walk test (6MWT) and lower extremity motor score (LEMS) in individuals with SCI and to compare those with conventional trainings. Methods: In this prospective, single-center, single-blinded randomized controlled pilot study, 18 SCI participants were randomized into the EAW group (n = 9) and conventional group (n = 9) and received 16 sessions of 50-60 min training (4 days/week, 4 weeks). Pulmonary function parameters consisting of the forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), forced expiratory flow (FEF), peak expiratory flow, and maximal voluntary ventilation, 6MWT with assisted devices and LEMS were reported pre- and post-training. Results: Values of FVC (p = 0.041), predicted FVC% (p = 0.012) and FEV1 (p = 0.013) were significantly greater in EAW group (FVC: 3.8 +/- 1.1 L; FVC% (pred) = 94.1 +/- 24.5%; FEV1: 3.5 +/- 1.0 L) compared with conventional group (FVC: 2.8 +/- 0.8 L; FVC% (pred) = 65.4 +/- 17.6%; FEV1: 2.4 +/- 0.6 L) after training. Participants in EAW group completed 6MWT with median 17.3 m while wearing the exoskeleton. There was no difference in LEMS and no adverse event. Conclusions: The current results suggest that EAW has potential benefits to facilitate PF parameters among individuals with lower thoracic neurological level of SCI compared with conventional trainings. Additionally, robotic exoskeleton helped walking.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Letter to the editor regarding "Clinical effectiveness and safety of powered exoskeleton-assisted walking in patients with spinal cord injury: systematic review with meta-analysis" Reply
    Miller, Larry E.
    Zimmermann, Angela K.
    Herbert, William G.
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2016, 9 : 421 - 421
  • [32] Balance Control and Energetics of Powered Exoskeleton-Assisted Sit-to-Stand Movement in Individuals With Paraplegic Spinal Cord Injury
    Mao, Hui-Fen
    Huang, Hsing-Po
    Lu, Tung-Wu
    Wang, Ting-Ming
    Wu, Cheng-Hua
    Hu, Jwu-Sheng
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2018, 99 (10): : 1982 - 1990
  • [33] Walking Stability During Normal Walking and Its Association with Slip Intensity Among Individuals with Incomplete Spinal Cord Injury
    Arora, Tarun
    Musselman, Kristin E.
    Lanovaz, Joel L.
    Linassi, Gary
    Arnold, Catherine
    Milosavljevic, Stephan
    Oates, Alison
    PM&R, 2019, 11 (03) : 270 - 277
  • [34] Mechanisms for improving walking speed after longitudinal powered robotic exoskeleton training for individuals with spinal cord injury
    Ramanujam, Arvind
    Momeni, Kamyar
    Husain, Syed R.
    Augustine, Jonathan
    Garbarini, Erica
    Barrance, Peter
    Spungen, Ann
    Asselin, Pierre
    Knezevic, Steven
    Forrest, Gail F.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 2805 - 2808
  • [35] Stance controlled knee flexion improves stimulation driven walking after spinal cord injury
    Thomas C Bulea
    Rudi Kobetic
    Musa L Audu
    Ronald J Triolo
    Journal of NeuroEngineering and Rehabilitation, 10
  • [36] Stance controlled knee flexion improves stimulation driven walking after spinal cord injury
    Bulea, Thomas C.
    Kobetic, Rudi
    Audu, Musa L.
    Triolo, Ronald J.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2013, 10
  • [37] Exoskeletal-Assisted Walking During Acute Inpatient Rehabilitation Enhances Recovery for Persons with Spinal Cord Injury-A Pilot Randomized Controlled Trial
    Tsai, Chung-Ying
    Weinrauch, William J.
    Manente, Nicholas
    Huang, Vincent
    Bryce, Thomas N.
    Spungen, Ann M.
    JOURNAL OF NEUROTRAUMA, 2024, 41 (17-18) : 2089 - 2100
  • [38] EFFECT OF LOWER EXTREMITY EXOSKELETON ROBOT IMPROVING WALKING FUNCTION AND ACTIVITY IN PATIENTS WITH COMPLETE SPINAL CORD INJURY
    Bai, Xingang
    Gou, Xiang
    Wang, Wenchun
    Dong, Chao
    Que, Fangxu
    Ling, Zesha
    Wang, Lan
    Zhou, Tingting
    Chen, Tian
    Pang, Rizhao
    Zhang, Anren
    Cheng, Hong
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (08)
  • [39] Robot-assisted gait training (Lokomat) improves walking function and activity in people with spinal cord injury: a systematic review
    Nam, Ki Yeun
    Kim, Hyun Jung
    Kwon, Bum Sun
    Park, Jin-Woo
    Lee, Ho Jun
    Yoo, Aeri
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2017, 14
  • [40] Robot-assisted gait training (Lokomat) improves walking function and activity in people with spinal cord injury: a systematic review
    Ki Yeun Nam
    Hyun Jung Kim
    Bum Sun Kwon
    Jin-Woo Park
    Ho Jun Lee
    Aeri Yoo
    Journal of NeuroEngineering and Rehabilitation, 14