Optimal interval screening and surveillance of abdominal aortic aneurysms

被引:68
|
作者
Lindholt, JS
Vammen, S
Juul, S
Fasting, H
Henneberg, EW
机构
[1] Viborg Hosp, Dept Vasc Surg, Viborg, Denmark
[2] Univ Aarhus, Inst Epidemiol & Social Med, DK-8000 Aarhus C, Denmark
关键词
abdominal aortic aneurysms; screening; surveillance; interval screening; rescreening;
D O I
10.1053/ejvs.2000.1191
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: to determine safe and optimal intervals of rescreening and surveillance for AAA. Methods: hospital-based mass screening of 6339 65-73-year-old men from 1994-98. 76.4% attended. One hundred and ninety-one (4%) had AAA greater than or equal to3 cm. Twenty-four (0.5%) were initially >5 cm and referred for surgery, while the rest were offered annual control scans to check for expansion. Later, all 348 (7.5%) men who 3 to 5 years ago had an ectatic aorta (infrarenal aortic diameter of 25-29 mm or distal/renal aortic diameter ratio >1.2) were offered rescreening. Of these, 62 (18%) died before rescanning, while 248 of the survivors attended rescreening (87%). Furthermore, a random sample of 380 of those with non-ectatic aortas were offered rescreening. Of these, 49 (13%) died before rescreening (p =0.06), while 275 (83%) of the survivors attended re-screening. Results: none of the controls had developed AAA. Of those who initially had an 25-29 mm aorta, 29% had developed AAA (size range 30-48 mm) with expansion rates varying from 1.0 to 4.7 mm/year. Only 3.5% with a ratio >1.2 developed AAA (size range: 30-34 mm) with expansion rates from 2.3 to 2.4 mm/year. During the fourth year of surveillance some AAA initially sized below 3.5 cm expanded to above 5 cm, while some sized 3.5-3.9 cm did so during the second year; >4 cm did so during the first year of surveillance. Concluison: rescreening for AAA can be restricted to initially ectatic aortas sized 25-29 mm at 5-year intervals. Surveillance of small AAA can be restricted to 1-4 year intervals.
引用
收藏
页码:369 / 373
页数:5
相关论文
共 50 条
  • [1] Screening of abdominal aortic aneurysms
    Collins, C. G.
    Leahy, A. L.
    SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2006, 4 (02): : 83 - 85
  • [2] Screening for abdominal aortic aneurysms
    Kostun, Zachary W.
    Malik, Rajesh K.
    CLINICAL IMAGING, 2016, 40 (02) : 321 - 324
  • [3] Ultrasound screening for abdominal aortic aneurysms
    Engelberger, Stephan
    Rosso, Raffaele
    Sarti, Manuela
    Del Grande, Filippo
    Canevascini, Reto
    van den Berg, Jos
    Prouse, Giorgio
    Giovannacci, Luca
    SWISS MEDICAL WEEKLY, 2017, 147
  • [4] Controversies in screening for abdominal aortic aneurysms
    Paraskevas, Kosmas I.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 293 : 224 - 224
  • [5] Should the Frequency of Surveillance for Small Abdominal Aortic Aneurysms be Reduced?
    Powell, J. T.
    Thompson, S. G.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (02) : 171 - 172
  • [6] Epidemiology and screening strategies in abdominal aortic aneurysms
    Schmitz-Rixen T.
    Debus S.E.
    Grundmann R.T.
    Gefässchirurgie, 2017, 22 (1) : 31 - 40
  • [7] Screening for abdominal aortic aneurysms in cardiovascular patients
    Hanly, AM
    Javad, S
    Anderson, LP
    Horgan, J
    Kelly, CJ
    JOURNAL OF SURGICAL RESEARCH, 2006, 132 (01) : 52 - 55
  • [8] Ultrasonographic Screening for the Detection of Abdominal Aortic Aneurysms
    Eckstein, H.
    Boeckler, D.
    Flessenkaemper, I
    Schmitz-Rixen, T.
    Debus, S.
    Lang, W.
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2009, 106 (41): : 657 - U9
  • [9] The management of ruptured abdominal aortic aneurysms: screening for abdominal aortic aneurysm and incidence of rupture
    Von Allmen, R. S.
    Powell, J. T.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2012, 53 (01) : 69 - 76
  • [10] What is the role of screening in the management of abdominal aortic aneurysms?
    Dabare, Dilan
    Lo, Tammy T. H.
    McCormack, David J.
    Kung, Victor W. S.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 14 (04) : 399 - 405