The predictability of graft thickness for Descemet's stripping automated endothelial keratoplasty using a mechanical microkeratome system

被引:0
|
作者
Nishisako, Sota [1 ]
Yamaguchi, Takefumi [2 ]
Kusano, Yuki [3 ]
Higa, Kazunari [1 ]
Aoki, Dai [1 ]
Sasaki, Chiaki [1 ]
Shimazaki, Jun [1 ,2 ]
机构
[1] Ichikawa Gen Hosp, Tokyo Dent Coll, Cornea Ctr & Eye Bank, Chiba, Japan
[2] Ichikawa Gen Hosp, Tokyo Dent Coll, Dept Ophthalmol, Chiba, Japan
[3] Kumamoto Univ, Dept Ophthalmol, Kumamoto, Japan
来源
SCIENTIFIC REPORTS | 2022年 / 12卷 / 01期
关键词
CORNEAL HYSTERESIS; ULTRATHIN GRAFTS; RISK-FACTOR; SINGLE; PRESSURE; TISSUE; DSAEK;
D O I
10.1038/s41598-022-26679-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Descemet's stripping automated endothelial keratoplasty (DSAEK) is used for treating corneal endothelial dysfunction, and the postoperative visual acuity outcome depends on the thickness of the graft. We created a simple nomogram using factors affecting the cutting thickness during graft preparation via a mechanical microkeratome system for DSAEK. This retrospective study was conducted from May 2018 through October 2022 and included donor eyes cut by automatic methods. We measured the graft thickness, cutting accuracy, and assessed ten variables with donor/cornea-related factors potentially affecting the cutting thickness. Subsequently, we created a simple nomogram. We analyzed 81 donor tissues, and the donor median age was 76 years. The mean central graft thickness was 122.2 mu m, with 62% of the grafts that could be cut within the target central graft thickness range. Comparatively, donor corneas from those with cardiac diseases were cut deeper (P=0.007). The developed nomogram provided a 83% probability of estimating the post-cutting graft thickness within 25 mu m. Our nomogram, which considers cause of death, enables reproducible production of graft of a desired thickness. A detailed analysis of donor tissues, including the cause of donor death and the characteristics from pressurization to cutting, will enable more precise DSAEK graft preparation.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Does thickness matter: ultrathin Descemet stripping automated endothelial keratoplasty
    Busin, Massimo
    Albe, Elena
    CURRENT OPINION IN OPHTHALMOLOGY, 2014, 25 (04) : 312 - 318
  • [42] Detachment of Donor Graft After Descemet Stripping Automated Endothelial Keratoplasty
    Sykakis, Evripidis
    Georgoudis, Panagiotis
    Hamada, Samer
    Lake, Damian
    JAMA OPHTHALMOLOGY, 2015, 133 (02) : e143259
  • [43] Influence of Donor Thickness on Visual Acuity in Descemet's Stripping Automated Endothelial Keratoplasty
    Kuzman, Tomislav
    Meter, Ana
    Kalauz, Miro
    Masnec, Sanja
    Skegro, Ivan
    Jonjic, Ivana
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2022, 17 (04) : 462 - 469
  • [44] Effect of venting incisions on graft attachment in Descemet's stripping automated endothelial keratoplasty
    Mohebbi, Masoumeh
    Rahimi, Firoozeh
    Hashemian, Mohammad Naser
    Zare, Mohammad Ali
    Fallah, Mohammad Reza
    Garoosi, Bahram
    Masoumi, Ahmad
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2018, 30 (02): : 142 - 146
  • [45] Changes in Macular Thickness After Descemet Stripping Automated Endothelial Keratoplasty
    Mashor, Raneen Shehadeh
    Nasser, Orwa
    Sansanayudh, Wiwan
    Rootman, David S.
    Slomovic, Allan R.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (03) : 415 - 418
  • [46] Retrephination of Eccentric Donor Graft for Descemet Stripping Automated Endothelial Keratoplasty
    Kymionis, George D.
    Diakonis, Vasilios F.
    Papathanasiou, Miltiadis
    Yoo, Sonia H.
    CORNEA, 2011, 30 (09) : 1058 - 1060
  • [47] Clinical Outcomes of Replacing a Failed Descemet's Stripping Automated Endothelial Keratoplasty Graft
    Bauer, Alex
    Potts, Luke
    Chen, Shin-Yi
    Tran, Khoa D.
    Straiko, Michael D.
    Terry, Mark A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [48] Topographic characteristics after Descemet's membrane endothelial keratoplasty and Descemet's stripping automated endothelial keratoplasty
    Hayashi, Takahiko
    Yamaguchi, Takefumi
    Yuda, Kentaro
    Kato, Naoko
    Satake, Yoshiyuki
    Shimazaki, Jun
    PLOS ONE, 2017, 12 (11):
  • [49] Graft Rejection After Descemet's Stripping Automated Endothelial Keratoplasty Graft Survival and Endothelial Cell Loss
    Li, Jennifer Y.
    Terry, Mark A.
    Goshe, Jeffrey
    Shamie, Neda
    Davis-Boozer, David
    OPHTHALMOLOGY, 2012, 119 (01) : 90 - 94
  • [50] Corneal Graft Detection for Descemet's Stripping Automated Endothelial Keratoplasty using Optical Coherence Tomography
    Lee, Beng Hai
    Liu, Jiang
    Tan, Zehao
    Heng, Eugene
    Cheng, Jun
    Tan, Ngan Meng
    Wong, Damon Wing Kee
    Trucco, Emauele
    Mehta, Jodhbir
    Wong, Tien Yin
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3037 - 3040