The predictability of graft thickness for Descemet's stripping automated endothelial keratoplasty using a mechanical microkeratome system

被引:0
|
作者
Nishisako, Sota [1 ]
Yamaguchi, Takefumi [2 ]
Kusano, Yuki [3 ]
Higa, Kazunari [1 ]
Aoki, Dai [1 ]
Sasaki, Chiaki [1 ]
Shimazaki, Jun [1 ,2 ]
机构
[1] Ichikawa Gen Hosp, Tokyo Dent Coll, Cornea Ctr & Eye Bank, Chiba, Japan
[2] Ichikawa Gen Hosp, Tokyo Dent Coll, Dept Ophthalmol, Chiba, Japan
[3] Kumamoto Univ, Dept Ophthalmol, Kumamoto, Japan
来源
SCIENTIFIC REPORTS | 2022年 / 12卷 / 01期
关键词
CORNEAL HYSTERESIS; ULTRATHIN GRAFTS; RISK-FACTOR; SINGLE; PRESSURE; TISSUE; DSAEK;
D O I
10.1038/s41598-022-26679-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Descemet's stripping automated endothelial keratoplasty (DSAEK) is used for treating corneal endothelial dysfunction, and the postoperative visual acuity outcome depends on the thickness of the graft. We created a simple nomogram using factors affecting the cutting thickness during graft preparation via a mechanical microkeratome system for DSAEK. This retrospective study was conducted from May 2018 through October 2022 and included donor eyes cut by automatic methods. We measured the graft thickness, cutting accuracy, and assessed ten variables with donor/cornea-related factors potentially affecting the cutting thickness. Subsequently, we created a simple nomogram. We analyzed 81 donor tissues, and the donor median age was 76 years. The mean central graft thickness was 122.2 mu m, with 62% of the grafts that could be cut within the target central graft thickness range. Comparatively, donor corneas from those with cardiac diseases were cut deeper (P=0.007). The developed nomogram provided a 83% probability of estimating the post-cutting graft thickness within 25 mu m. Our nomogram, which considers cause of death, enables reproducible production of graft of a desired thickness. A detailed analysis of donor tissues, including the cause of donor death and the characteristics from pressurization to cutting, will enable more precise DSAEK graft preparation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Reattachment of a posteriorly dislocated graft in Descemet's stripping automated endothelial keratoplasty
    Tarini, Shilpa
    Panchal, Bhavik
    BMJ CASE REPORTS, 2024, 17 (12)
  • [22] Corneal Endothelial Cell Loss and Graft Thickness Following Descemet-Stripping Automated Endothelial Keratoplasty
    Inatomi, T.
    Adachi, H.
    Tanioka, H.
    Hieda, O.
    Kinoshita, S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [23] Descemet Stripping Automated Endothelial Keratoplasty for Repeated Penetrating Keratoplasty Graft Failure
    Hwang, Gyu Deok
    Yun, Hye Yeon
    Ha, Min Ji
    Whang, Woong Joo
    Chang, Dong Jin
    Hwang, Ho Sik
    Na, Kyung Sun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2021, 62 (03): : 394 - 399
  • [24] Descemet stripping automated endothelial keratoplasty
    Sharma, Namrata
    Maharana, Prafulla K.
    Singhi, Shipra
    Aron, Neelima
    Patil, Mukesh
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (03) : 198 - 209
  • [25] Microkeratome-Assisted Preparation of Ultrathin Grafts for Descemet Stripping Automated Endothelial Keratoplasty
    Busin, Massimo
    Patel, Amit K.
    Scorcia, Vincenzo
    Ponzin, Diego
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (01) : 521 - 524
  • [26] Descemet's stripping with automated endothelial keratoplasty (DSAEK)
    Cursiefen, C.
    Kruse, F. E.
    OPHTHALMOLOGE, 2008, 105 (02): : 183 - +
  • [27] Descemet's stripping automated endothelial keratoplasty (DSAEK)
    Cursiefen, C.
    Kruse, F. E.
    OPHTHALMOLOGE, 2009, 106 (10): : 939 - 952
  • [28] Effect of Cornea Donor Graft Thickness on the Outcome of Descemet Stripping Automated Endothelial Keratoplasty Surgery
    Daoud, Yassine J.
    Munro, Andrew D.
    Delmonte, Derek D.
    Stinnett, Sandra
    Kim, Terry
    Carlson, Alan N.
    Afshari, Natalie A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (05) : 860 - 866
  • [29] Refractive outcomes after descemet stripping automated endothelial keratoplasty surgery associated with graft thickness
    Cheung, Natalie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [30] Comparison of Graft Thickness Measured by an Eye Bank With Graft Thickness Measured After Descemet Stripping Automated Endothelial Keratoplasty
    Feizi, Sepehr
    Delfazayebaher, Siamak
    Masoudi, Ali
    Babamohamadi, Zahra
    Javadi, Mohammad Ali
    CORNEA, 2019, 38 (04) : 403 - 408