A continuous flow cell culture system for precision cell stimulation and time-resolved profiling of cell secretion

被引:8
作者
Erickson, Patrick [1 ]
Houwayek, Tony [2 ]
Burr, Alexandra [2 ]
Teryek, Matthew [2 ]
Parekkadan, Biju [2 ,3 ]
机构
[1] Rutgers State Univ, Dept Chem & Biochem Engn, Piscataway, NJ 08854 USA
[2] Rutgers State Univ, Dept Biomed Engn, Piscataway, NJ 08854 USA
[3] Rutgers Biomed Hlth Sci, Dept Med, New Brunswick, NJ 08852 USA
基金
美国国家卫生研究院;
关键词
Bioreactor; Circadian; Dynamics; Residence time distribution; Secretion; Stimulation; PERFUSION CULTURE; CHALLENGES; EXPRESSION; CLOCK;
D O I
10.1016/j.ab.2021.114213
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cells exchange substances with their surroundings during metabolism, signaling, and other functions. These fluxes are dynamic, changing in response to external cues and internal programs. Static cultures are inadequate for measuring these dynamics because the environments of the cells change as substances accumulate or deplete from medium, unintentionally affecting cell behavior. Static cultures offer limited time resolution due to the impracticality of frequent or prolonged manual sampling, and cannot expose cells to smooth, transient changes in stimulus concentrations. In contrast, perfusion cultures constantly maintain cellular environments and continuously sample the effluent stream. Existing perfusion culture systems are either microfluidic, which are difficult to make and use, or macrofluidic devices built from custom parts that neglect solute dispersion. In this study, a multiplexed macrofluidic perfusion culture platform was developed to measure secretion and absorption rates of substances by cells in a temporally controlled environment. The modular platform handles up to 31 streams with automated fraction collection. This paper presents the assembly of this dynamic bioreactor from commercially available parts, and a method for quantitatively handling the effects of dispersion using residence time distributions. The system is then applied to monitor the secretion of a circadian clock gene-driven reporter from engineered cells.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Development of an optical time-resolved measurement system under high-pressure and low-temperature with a piston-cylinder pressure cell
    Tsuchiya, Satoshi
    Kino, Yohei
    Nakagawa, Koichi
    Nakagawa, Daisuke
    Yamada, Jun-ichi
    Toda, Yasunori
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (04)
  • [32] Pump less steady-flow microfluidic chip for cell culture
    Marimuthu, Mohana
    Kim, Sanghyo
    ANALYTICAL BIOCHEMISTRY, 2013, 437 (02) : 161 - 163
  • [33] Microfluidic cell culture system studies and computational fluid dynamics
    Huang, Manguo
    Fan, Shangchun
    Xing, Weiwei
    Liu, Changting
    MATHEMATICAL AND COMPUTER MODELLING, 2010, 52 (11-12) : 2036 - 2042
  • [34] Multimodal and spatially resolved profiling identifies distinct patterns of T cell infiltration in nodal B cell lymphoma entities
    Roider, Tobias
    Baertsch, Marc A.
    Fitzgerald, Donnacha
    Voehringer, Harald
    Brinkmann, Berit J.
    Czernilofsky, Felix
    Knoll, Mareike
    Llao-Cid, Laura
    Mathioudaki, Anna
    Fassbender, Bianca
    Herbon, Maxime
    Lautwein, Tobias
    Bruch, Peter-Martin
    Liebers, Nora
    Schuerch, Christian M.
    Passerini, Verena
    Seifert, Marc
    Brobeil, Alexander
    Mechtersheimer, Gunhild
    Mueller-Tidow, Carsten
    Weigert, Oliver
    Seiffert, Martina
    Nolan, Garry P.
    Huber, Wolfgang
    Dietrich, Sascha
    NATURE CELL BIOLOGY, 2024, 26 (03) : 478 - 489
  • [35] An efficient cell culture system for the studies of heterogeneous astrocytes: Time gradient digestion
    Li, Yu
    Zhou, Pei
    Zheng, Shuxin
    Liao, Caihua
    Yang, Miaomiao
    Gao, Shengli
    Wang, Xiaoya
    Chen, Yanqiu
    Sun, Changzhi
    Luo, Renzhong
    Huang, Yongjin
    Li, Na
    Hu, Hao
    JOURNAL OF NEUROSCIENCE METHODS, 2021, 362
  • [36] Hybridoma cell behaviour in continuous culture under hyperosmotic stress
    Marc Cherlet
    Annie Marc
    Cytotechnology, 1999, 29 : 71 - 84
  • [37] Time-resolved fluoroimmunoassay for Aspergillus detection based on anti-galactomannan monoclonal antibody from stable cell line
    Wang, Wenjun
    Liu, Chunlong
    Zhang, Xuemei
    Yan, Jun
    Zhang, Jiaxing
    You, Shengping
    Su, Rongxin
    Qi, Wei
    ANALYTICAL BIOCHEMISTRY, 2024, 689
  • [38] Metabolite profiling of microfluidic cell culture conditions for droplet based screening
    Bjork, Sara M.
    Sjostrom, Staffan L.
    Andersson-Svahn, Helene
    Joensson, Haakan N.
    BIOMICROFLUIDICS, 2015, 9 (04)
  • [39] Hybridoma cell behaviour in continuous culture under hyperosmotic stress
    Cherlet, M
    Marc, A
    CYTOTECHNOLOGY, 1999, 29 (01) : 71 - 84
  • [40] Endothelial Cell–Smooth Muscle Cell Co-Culture in a Perfusion Bioreactor System
    Chrysanthi Williams
    Timothy M. Wick
    Annals of Biomedical Engineering, 2005, 33 : 920 - 928