Fabrication of a multilayer film electrode containing porphyrin and its application as a potentiometric sensor of iodide ion

被引:29
作者
Sun, CQ [1 ]
Zhao, JH
Xu, HD
Sun, YP
Zhang, X
Shen, JC
机构
[1] Jilin Univ, Dept Chem, Changchun 130023, Peoples R China
[2] Jilin Univ, Key Lab Supramol Spectra & Struct, Changchun 130023, Peoples R China
关键词
multilayer films; sensor; potentiometry; iodide ion; porphyrin;
D O I
10.1016/S0039-9140(97)00256-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel iodide ion-selective electrode has been produced based on a molecular deposition technique in which water-soluble porphyrin was alternatively deposited with water-soluble polypyrrole on a 2-aminoethanethiol modified silver electrode. The potentiometric response is independent of pH of the solution between pH 1 and 7, while it is dependent on the nature of the medium. The electrode has a linear dynamic range between 1.6 x 10(-6) and 0.1 M with a Nernstian slope of 59 mV/decade and a detection limit of 1.0 x 10(-6) M in acetate buffer (0.1 M, pH 4.6). The electrode has the advantages of low resistance, short conditioning time and fast response. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 50 条
[41]   Determination of betamethasone sodium phosphate in pharmaceuticals by potentiometric membrane sensor based on its lidocaine ion pair [J].
M. Giahi ;
O. Marvi ;
F. Safari ;
B. Chahkandi .
Journal of Analytical Chemistry, 2013, 68 :900-905
[42]   Determination of betamethasone sodium phosphate in pharmaceuticals by potentiometric membrane sensor based on its lidocaine ion pair [J].
Giahi, M. ;
Marvi, O. ;
Safari, F. ;
Chahkandi, B. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (10) :900-905
[43]   One-pot synthesis of porphyrin@polypyrrole hybrid and its application as an electrochemical sensor [J].
Peshoria, Shruti ;
Narula, Anudeep Kumar .
MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2018, 229 :53-58
[44]   Preparation of a Fluconazole Potentiometric Sensor and its Application to Pharmaceutical Analysis and to Drug Recovery from Biological Fluids [J].
Ershad, Sohrab ;
Kangari, Sahar .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (08) :1100-1108
[45]   Preparation of a diclofenac potentiometric sensor and its application to pharmaceutical analysis and to drug recovery from biological fluids [J].
Shamsipur, M ;
Jalali, F ;
Ershad, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (05) :943-947
[46]   Preparation of a cimetidine ion-selective electrode and its application to pharmaceutical analysis [J].
Shamsipur, M ;
Jalali, F ;
Haghgoo, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (06) :867-872
[47]   Preparation of an atenolol ion-selective electrode and its application to pharmaceutical analysis [J].
Shamsipur, M ;
Jalali, F ;
Haghgoo, S .
ANALYTICAL LETTERS, 2005, 38 (03) :401-410
[48]   Development and application of a fast solid-state potentiometric CO2-Sensor in thick-film technology [J].
Wiegaertner, Sven ;
Kita, Jaroslaw ;
Hagen, Gunter ;
Schmaus, Christa ;
Kiessig, Andre ;
Glaser, Eckard ;
Bolz, Armin ;
Moos, Ralf .
28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014), 2014, 87 :1031-1034
[49]   Preparation and characterisation of a quinone-functionalised polythiophene film on a modified electrode. Application to the potentiometric determination of glutathione and cysteine concentrations [J].
Etienne, Stephanie ;
Matt, Muriel ;
Oster, Thierry ;
Samadi, Mohammad ;
Beley, Marc .
TETRAHEDRON, 2008, 64 (40) :9619-9624
[50]   Potentiometric SO2 gas sensor based on a thick film of Ca2+ ion conducting solid electrolyte [J].
L. Wang ;
R.V. Kumar .
Journal of Applied Electrochemistry, 2006, 36 :173-178