Initial experience with slimmest single-use flexible ureteroscope Uscope PU3033A (PUSEN™) in retrograde intrarenal surgery and its comparison with Uscope PU3022a: a single-center prospective study

被引:17
作者
Agrawal, Shashank [1 ,2 ]
Patil, Abhijit [1 ]
Sabnis, Ravindra B. [1 ]
Singh, Abhishek G. [1 ]
Ganpule, Arvind P. [1 ]
Desai, Mahesh R. [1 ]
机构
[1] Muljibhai Patel Urol Hosp, Nadiad, India
[2] Muljibhai Patel Urol Hosp, Dept Urol, Dr Virendra Desai Rd, Nadiad 387991, Gujarat, India
关键词
Single-use; Digital; Flexible; Ureterorenoscope; CLINICAL-RESEARCH OFFICE; URETERAL ACCESS SHEATH; RENAL STONES; DIGITAL URETEROSCOPE; CM; LITHOVUE; OUTCOMES; SIZE;
D O I
10.1007/s00345-021-03707-4
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose Single-use disposable digital flexible ureterorenoscope has become an attractive option to reusable scope with many advantages. Currently available single-use digital fURS have outer shaft diameter above 9 Fr which requires large access sheath insertion and sometimes double J stent placement. Recently, 7.5 Fr single-use digital fURS is introduced in market by Pusen. Objective of this study is to compare two Pusen single-use scopes in the clinical setting: 7.5 Fr Uscope PU3033A and 9.5 Fr Uscope PU3022A. Methods 30 patients, having renal stones < 2 cm, planned for RIRS were prospectively randomized to two groups: group 1 had 15 patients in which 7.5 Fr Uscope PU3033A and group 2 had 15 patients in which 9.5 Fr Uscope PU3022A was used. The various pre-operative, intra-operative, and post-operative parameters at 1 month along with complications were evaluated for both the scopes by a single surgical team. Results Pre-operative parameters including stone characteristics were comparable in both the groups. Three patients in group 2 needed ureteric dilatation prior to 11/13 access sheath insertion, while 10/12 Fr access sheath was placed in all patients in group 1 without manipulation (p = 0.06). Intra-operative vision was comparable in both scopes with an empty working channel and with laser. Hazy vision while lasing in two and one patient in group 1 and group 2, respectively (p = 0.54). In group 1, one had fever and UTI, while in group 2, one had fever post-operatively. Conclusion 7.5 Fr Uscope PU3033A could be introduced with smaller access sheath. The vision, deflection, maneuverability is comparable to 9.5 Fr Uscope PU3022a.
引用
收藏
页码:3957 / 3962
页数:6
相关论文
共 28 条
[1]   Preoperative JJ stent placement in ureteric and renal stone treatment: results from the Clinical Research Office of Endourological Society (CROES) ureteroscopy (URS) Global Study [J].
Assimos, Dean ;
Crisci, Alfonso ;
Culkin, Daniel ;
Xue, Wei ;
Roelofs, Anita ;
Duvdevani, Mordechai ;
Desai, Mahesh ;
de la Rosette, Jean .
BJU INTERNATIONAL, 2016, 117 (04) :648-654
[2]  
Astroza G, 2017, CENT EUR J UROL, V70, P88, DOI 10.5173/ceju.2016.919
[3]   The New Digital Flexible Ureteroscopes: 'Size Does Matter' - Increased Ureteric Access Sheath Use! [J].
Bach, C. ;
Nesar, S. ;
Kumar, P. ;
Goyal, A. ;
Kachrilas, S. ;
Papatsoris, A. ;
Masood, J. ;
Buchholz, N. .
UROLOGIA INTERNATIONALIS, 2012, 89 (04) :408-411
[4]   FLEXIBLE URETEROPYELOSCOPY - DIAGNOSIS AND TREATMENT IN THE UPPER URINARY-TRACT [J].
BAGLEY, DH ;
HUFFMAN, JL ;
LYON, ES .
JOURNAL OF UROLOGY, 1987, 138 (02) :280-285
[5]   Preoperative Stenting Decreases Operative Time and Reoperative Rates of Ureteroscopy [J].
Chu, Lei ;
Sternberg, Kevan M. ;
Averch, Timothy D. .
JOURNAL OF ENDOUROLOGY, 2011, 25 (05) :751-754
[6]   The Clinical Research Office of the Endourological Society Ureteroscopy Global Study: Indications, Complications, and Outcomes in 11,885 Patients [J].
de la Rosette, Jean ;
Denstedt, John ;
Geavlete, Petrisor ;
Keeley, Francis ;
Matsuda, Tadashi ;
Pearle, Margaret ;
Preminger, Glenn ;
Traxer, Olivier .
JOURNAL OF ENDOUROLOGY, 2014, 28 (02) :131-139
[7]   Characteristics of current digital single-use flexible ureteroscopes versus their reusable counterparts: an in-vitro comparative analysis [J].
Dragos, Laurian B. ;
Somani, Bhaskar K. ;
Keller, Etienne X. ;
De Coninck, Vincent M. J. ;
Herrero, Maria Rodriguez-Monsalve ;
Kamphuis, Guido M. ;
Bres-Niewada, Ewa ;
Sener, Emre T. ;
Doizi, Steeve ;
Wiseman, Oliver J. ;
Traxer, Olivier .
TRANSLATIONAL ANDROLOGY AND UROLOGY, 2019, 8 :S359-S370
[8]  
Giusti G, 2014, CAN J UROL, V21, P7207
[9]   Single-use disposable digital flexible ureteroscopes: an ex vivo assessment and cost analysis [J].
Hennessey, Derek B. ;
Fojecki, Grzegorz L. ;
Papa, Nathan P. ;
Lawrentschuk, Nathan ;
Bolton, Damien .
BJU INTERNATIONAL, 2018, 121 :55-61
[10]   Ureteric access with flexible ureteroscopes: effect of the size of the ureteroscope [J].
Hudson, RG ;
Conlin, MJ ;
Bagley, DH .
BJU INTERNATIONAL, 2005, 95 (07) :1043-1044