Confining stress path-based compressive strength model of axially compressed circular concrete-filled double-skin steel tubular short columns

被引:36
|
作者
Yan, Xi-Feng [1 ]
Zhao, Yan-Gang [1 ,2 ]
Lin, Siqi [2 ]
Zhang, Haizhong [1 ]
机构
[1] Kanagawa Univ, Dept Architect & Bldg Engn, Yokohama, Kanagawa 2218686, Japan
[2] Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing 100124, Peoples R China
基金
中国博士后科学基金; 美国国家科学基金会;
关键词
Confining stress path (CSP); CSP effect; Compressive strength; Concrete-filled double-skin steel tubes (CFDSTs); CFDST STUB COLUMNS; NONLINEAR-ANALYSIS; STRAIN MODEL; CHS INNER; BEHAVIOR; TUBE; PERFORMANCE; OUTER; DEPENDENCE; DESIGN;
D O I
10.1016/j.tws.2021.107949
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Previous investigations have shown that the confining stress paths (CSPs) of confined concrete significantly affected the compressive behaviour of confined concrete in fibre-reinforced polymer (FRP) confined concrete or concrete-filled steel tube (CFST) columns. Unlike the concrete in FRP-confined concrete or CFST columns, which is only confined by external materials, e.g., FRP sheet or steel tube, the concrete in concrete-filled double-skin steel tubular (CFDST) columns is confined by both the external and internal steel tubes. Due to different confinement mechanisms, the CSPs of confined concrete in CFDST columns may be different from those in FRP-confined concrete or CFST ones, but they have not been investigated so far. In this paper, the CSPs of confined concrete in circular CFDST stub columns were experimentally investigated, and their corresponding influences on the compressive strength were also discussed. It is shown that the CSPs of confined concrete induced by the external tube are considerably influenced by column variables, whereas those generated by the internal tube found no obvious trend. Moreover, the results suggest that the compressive strength of confined concrete in specimens with a confinement coefficient eta less than 2.731 is CSP-dependent, based on which, a compressive strength model of confined concrete considering the CSP effect is developed for circular CFDST columns. Based on this model, a CSP-based compressive strength model for estimating the ultimate strength of CFDST columns is proposed, and comparison with existing models against the collected test data indicates a higher accuracy of the predictions for the proposed model.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Finite element analysis on the capacity of circular concrete-filled double-skin steel tubular (CFDST) stub columns
    Pagoulatou, M.
    Sheehan, T.
    Dai, X. H.
    Lam, D.
    ENGINEERING STRUCTURES, 2014, 72 : 102 - 112
  • [32] Axial Compressive Behavior of Thin-Walled Concrete-Filled Double-Skin Steel Tubular Stub Columns with Connecting Strips
    Shen, Le
    Ding, Miao
    Feng, Chen
    Alqawzai, Shagea
    Elchalakani, Mohamed
    Yang, Bo
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (02)
  • [33] An analytical model for axially compressed circular concrete-filled steel tubular (CFST) short columns with varied confinement factors
    Chang, Yanjun
    Rong, Enchao
    Wang, Xiangyu
    Jiang, Hui
    Teng, Xiaodan
    STRUCTURES, 2024, 66
  • [34] Fiber-based computational modeling of rectangular double-skin concrete-filled steel tubular short columns including local buckling
    Rizwan, Muhammad
    Qing Quan Liang
    Hadi, Muhammad N. S.
    ENGINEERING STRUCTURES, 2021, 248
  • [35] Machine learning-based strength prediction for circular concrete-filled double-skin steel tubular columns under axial compression
    Li, Shou-Zhen
    Wang, Jin-Jin
    Jiang, Liming
    Deng, Ran
    Wang, Yu-Hang
    ENGINEERING STRUCTURES, 2025, 325
  • [36] Compressive behaviour of tapered concrete-filled double skin steel tubular stub columns
    Deng, Ran
    Zhou, Xu-Hong
    Deng, Xiao-Wei
    Ke, Ke
    Bai, Jiu-Lin
    Wang, Yu-Hang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 184
  • [37] Concrete-filled double-skin aluminum circular hollow section stub columns
    Zhou, Feng
    Young, Ben
    THIN-WALLED STRUCTURES, 2018, 133 : 141 - 152
  • [38] Residual Strength of Concrete-Filled Double-Skin Steel Tubular Stub Columns after Exposure to Fire
    Yu, Xin
    Tao, Zhong
    Han, Lin-Hai
    Uy, Brian
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 483 - 488
  • [39] An efficient long short-term memory-based model for prediction of the load-displacement curve of concrete-filled double-skin steel tubular columns
    Le, Dai-Nhan
    Pham, Thai-Hoan
    Pham, Tuan-Dung
    Kong, Zhengyi
    Papazafeiropoulos, George
    Vu, Quang-Viet
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 449
  • [40] Simulation modeling and design of circular concrete-filled double-skin tubular slender beam-columns with outer stainless-steel tube
    Le, Tuan Trung
    Patel, Vipulkumar Ishvarbhai
    Liang, Qing Quan
    Huynh, Phat
    ENGINEERING STRUCTURES, 2023, 285