Pure orbital blowout fractures reconstructed with autogenous bone grafts: functional and aesthetic outcomes

被引:11
作者
Kronig, S. A. J. [1 ]
van der Mooren, R. J. G. [1 ]
Strabbing, E. M. [1 ]
Stam, L. H. M. [1 ]
Tan, J. A. S. L. [1 ]
de Jongh, E. [2 ]
van der Wal, K. G. H. [1 ]
Paridaens, D. [2 ,3 ]
Koudstaal, M. J. [1 ,2 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Oral & Maxillofacial Surg, Dr Molewaterpl 40, NL-3015 GD Rotterdam, Netherlands
[2] Rotterdam Eye Hosp, Oculoplast & Orbital Serv, Rotterdam, Netherlands
[3] Geneva Gen Hosp, Dept Ophthalmol, Geneva, Switzerland
关键词
orbital fractures; pure blowout; orbital reconstruction; autogenous bone; FLOOR FRACTURES; SURGICAL REPAIR; OUT FRACTURES; MANAGEMENT; IMPLANTS;
D O I
10.1016/j.ijom.2015.11.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to investigate the ophthalmic clinical findings following surgical reconstruction with autogenous bone grafts of pure blowout fractures. A retrospective review of 211 patients who underwent surgical repair of an orbital fracture between October 1996 and December 2013 was performed. Following data analysis, 60 patients who were followed up over a period of 1 year were included. A solitary floor fracture was present in 38 patients and a floor and a medial wall fracture in 22 patients. Comparing preoperative findings between these two groups, preoperative diplopia and enophthalmos were almost twice as frequent in the group with additional medial wall fractures: diplopia 8% and 14% and enophthalmos 18% and 55%, respectively. One year following surgery there was no diplopia present in either group. In the solitary floor fracture group, 3% still had enophthalmos. It can be concluded that at 1 year following the repair of pure orbital floor fractures using autogenous bone, good functional and aesthetic results can be obtained. In the group with both floor and medial wall fractures, no enophthalmos was found when both walls were reconstructed. When the medial wall was left unoperated, 29% of patients still suffered from enophthalmos after 1 year.
引用
收藏
页码:507 / 512
页数:6
相关论文
共 30 条
  • [1] Evolving Trends in the Management of Orbital Floor Fractures
    Aldekhayel, Salah
    Aljaaly, Hattan
    Fouda-Neel, Omar
    Shararah, Abdul-Wahab
    Zaid, Waleed Suliman
    Gilardino, Mirko
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (01) : 258 - 261
  • [2] Materials Used for Reconstruction After Orbital Floor Fracture
    Avashia, Yash J.
    Sastry, Ananth
    Fan, Kenneth L.
    Mir, Haaris S.
    Thaller, Seth R.
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 : 1991 - 1997
  • [3] CHOICE OF THERAPY AND CRITERIA FOR ASSESSING TREATMENT OUTCOME IN THYROID-ASSOCIATED OPHTHALMOPATHY
    BAHN, RS
    GORMAN, CA
    [J]. ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 1987, 16 (02) : 391 - 407
  • [4] Retrospective analysis of 301 patients with orbital floor fracture
    Bartoli, Davina
    Fadda, Maria Teresa
    Battisti, Andrea
    Cassoni, Andrea
    Pagnoni, Mario
    Riccardi, Emiliano
    Sanzi, Marcello
    Valentini, Valentino
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (02) : 244 - 247
  • [5] Diplopia after surgical repair of orbital floor fractures
    Biesman, BS
    Hornblass, A
    Lisman, R
    Kazlas, M
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 12 (01) : 9 - 16
  • [6] The diagnosis and management of orbital blowout fractures: Update 2001
    Brady, SM
    McMann, MA
    Mazzoli, RA
    Bushley, DM
    Ainbinder, DJ
    Carroll, RB
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2001, 19 (02) : 147 - 154
  • [7] Analysis of Complications After Surgical Repair of Orbital Fractures
    Brucoli, Matteo
    Arcuri, Francesco
    Cavenaghi, Roberta
    Benech, Arnaldo
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (04) : 1387 - 1390
  • [8] BURCHARDT H, 1983, CLIN ORTHOP RELAT R, P28
  • [9] Clinical recommendations for repair of isolated orbital floor fractures - An evidence-based analysis
    Burnstine, MA
    [J]. OPHTHALMOLOGY, 2002, 109 (07) : 1207 - 1210
  • [10] CONVERSE J M, 1957, Br J Plast Surg, V9, P265