Experimental investigation of eccentrically compressed stainless steel columns with constraints in fire

被引:18
作者
Fan, Shenggang [1 ]
Liu, Meijing [2 ]
Sun, Wenjun [3 ]
Guo, Yang [1 ]
Han, Yun Long [1 ]
机构
[1] Southeast Univ, Sch Civil Engn, Minist Educ, Key Lab Concrete & Prestressed Concrete Struct, Sipailou 2, Nanjing 210096, Jiangsu, Peoples R China
[2] Southeast Univ, Chengxian Coll, Dept Civil Engn, Nanjing 210088, Jiangsu, Peoples R China
[3] Tus Design Grp Co Ltd, Suzhou, Peoples R China
关键词
Stainless steel columns; Fire-resistance performance; Eccentric compression; Axial constraints; Buckling temperature; Load ratio; SQUARE HOLLOW SECTION; RESISTANCE; DESIGN;
D O I
10.1016/j.firesaf.2018.06.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To study the behaviour reaction and failure mechanism of stainless steel columns in fire, a series of fire tests were performed on the eccentrically compressed columns with constraints, based on S30408 stainless steel. 7 specimens were used to investigate the effects of the load ration, eccentricity e and axial constraint stiffness ratio beta on the fire-resistance performance of eccentrically compressed stainless steel columns. The failure process and failure modes of stainless steel columns in fire were revealed. The test phenomena, heating curve, deformation curve and buckling temperature were obtained. The test results show that the load ratio n (n = 0.22-0.35), eccentricity e and axial constraint stiffness ratio beta (beta = 0.0458 and 0.0495) are the key factors that determine the fire-resistance performance of eccentrically compressed stainless steel columns with constraints. The larger the load ratio n, eccentricity e and axial constraint stiffness ratio beta are, the lower the buckling temperature of the specimen. There are two main types of failure modes of eccentrically compressed stainless steel columns with constraints in fire: the first is the overall buckling mode and the second is the local-overall interaction buckling mode. The failure modes depend mainly on the section dimensions and the section type of the stainless steel column. The process of bearing capacity of eccentrically compressed stainless steel columns with constraints in fire goes through two stages: the prebuckling stage and the post-buckling stage. It takes times for the specimen to progress from the buckling state to the ultimate failure state. The bearing capacity of the post-buckling stage can effectively improve the fire-resistance performance of the stainless steel column with constraints.
引用
收藏
页码:49 / 62
页数:14
相关论文
共 26 条
[1]  
ALAOUTINEN T, 1999, P 2 EUR C STEEL STRU, P165
[2]  
[Anonymous], 2006, EN199314 EUR COMM ST
[3]  
Bailey C. G., 2005, STRUCT BUILD, V159, P21
[4]  
Ding X, 2013, THESIS
[5]  
Euro Inox/SCI, 2017, DES MAN STRUCT STAIL, V4
[6]  
European Committee for Standardization, 2005, EN199312
[7]  
Fan S. G., 2016, ENG MECH, V33
[8]   Experimental investigation on fire resistance of stainless steel columns with square hollow section [J].
Fan, Shenggang ;
Ding, Xiaofeng ;
Sun, Wenjun ;
Zhang, Liyuan ;
Liu, Meijing .
THIN-WALLED STRUCTURES, 2016, 98 :196-211
[9]   Numerical investigation on fire resistance of stainless steel columns with square hollow section under axial compression [J].
Fan, Shenggang ;
Zhang, Liyuan ;
Sun, Wenjun ;
Ding, Xiaofeng ;
Liu, Meijing .
THIN-WALLED STRUCTURES, 2016, 98 :185-195
[10]   Stainless steel structures in fire [J].
Gardner, L. .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2007, 160 (03) :129-138