Sensitive Voltammetric Determination of Cadmium(II) with 8-Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode

被引:2
|
作者
Jia, Shaohui [1 ]
Gong, Shixing [2 ]
Cheng, Yong [2 ]
Wang, Huiyun [1 ]
Liu, Hejian [2 ]
Zhang, Bo [1 ]
Sun, Wei [2 ]
机构
[1] Jining Med Univ, Sch Pharm, Jining 272100, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
关键词
8-Hydroxyquinoline; 1-Ethyl-3-methylimidazoliam ethylsulphate; Cadmium; Differential pulse anodic stripping voltammetry; Carbon paste electrode; STRIPPING VOLTAMMETRY; ELECTROCHEMICAL DETECTION; PERIPHERAL-BLOOD; FILM; LEAD(II); ANTIMONY; SPECTROMETRY; EXTRACTION; CHLORIDE; COPPER;
D O I
10.1002/jccs.201400177
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, 8-hydroxyquinoline (HQ) and ionic liquid (IL) modified carbon paste electrode was fabricated and used for the sensitive determination of cadmium(II) with differential pulse anodic stripping voltammetry (DPASV). The modified electrode was prepared by the addition of HQ and IL 1-ethyl-3-methylimidazoliam ethylsulphate as the modifiers into the traditional carbon paste mixture. Cd(II) was preconcentrated and reduced on the surface of the modified electrode at the potential of -1.0 V (vs. SCE) by the co-contributions from the formation of HQ-Cd(II) complex and the accumulation effect of IL. Then the reduced Cd on the electrode surface was reoxidized by DPASV with a sensitive oxidation peak appeared at -0.79 V (vs. SCE). Under the optimal conditions, the oxidation peak current was proportional to the Cd(II) concentration in the range from 0.03 to 2.0 mu mol/L with the detection limit as 5.0 nmol/L (3 sigma). The proposed method was successfully applied to the water samples detection with the recovery in the range from 95.6% to 96.6%.
引用
收藏
页码:1217 / 1222
页数:6
相关论文
共 50 条
  • [31] Construction of Modified Carbon Paste Electrode for Highly Sensitive Simultaneous Electrochemical Determination of Trace Amounts of Copper (II) and Cadmium (II)
    Afkhami, Abbas
    Soltani-Shahrivar, Morteza
    Ghaedi, Hamed
    Madrakian, Tayyebeh
    ELECTROANALYSIS, 2016, 28 (02) : 296 - 303
  • [32] Voltammetric Determination of Uric Acid Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode
    Motghare, Ramani V.
    Tadi, Kiran Kumar
    Dhawale, Payal
    Deotare, Samiksha
    Kawadkar, Aruna K.
    Chillawar, Rakesh
    Khan, Shirinaz
    ELECTROANALYSIS, 2015, 27 (03) : 825 - 832
  • [33] Simultaneous anodic stripping voltammetric determination of lead and cadmium with a carbon paste electrode modified by tributyl phosphate
    Huang, SS
    Cheng, YD
    Li, BF
    Liu, GD
    MIKROCHIMICA ACTA, 1998, 130 (1-2) : 97 - 101
  • [34] Sensitive voltammetric determination of rutin at a carbon nanotubes-ionic liquid composite electrode
    Wang, Xiaolei
    Cheng, Cuicui
    Dong, Ranran
    Hao, Jingcheng
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (08) : 2815 - 2821
  • [35] Catalytic adsorptive stripping voltammetric determination of copper(II) on a carbon paste electrode
    Ning Liu
    Jun-Feng Song
    Analytical and Bioanalytical Chemistry, 2005, 383 : 358 - 364
  • [36] Catalytic adsorptive stripping voltammetric determination of copper(II) on a carbon paste electrode
    Liu, N
    Song, JF
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) : 358 - 364
  • [37] Voltammetric determination of cadmium(II) using a chemically modified electrode
    Shengshui Hu
    Kangbing Wu
    Hongchao Yi
    Xuan Dai
    Dafu Cui
    Fresenius' Journal of Analytical Chemistry, 2001, 370 : 101 - 103
  • [38] Simultaneous anodic stripping voltammetric determination of lead and cadmium with a carbon paste electrode modified by tributyl phosphate
    Sha-Sheng Huang
    Yi-Da Cheng
    Bi-Fen Li
    Guo-Dong Liu
    Microchimica Acta, 1998, 130 : 97 - 101
  • [39] A voltammetric biosensor based on ionic liquid/NiO nanoparticle modified carbon paste electrode for the determination of nicotinamide adenine dinucleotide (NADH)
    Karimi-Maleh, Hassan
    Sanati, Afsaneh L.
    Gupta, Vinod Kumar
    Yoosefian, Mehdi
    Asif, Mohammad
    Bahari, Ali
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 647 - 654
  • [40] Application of ionic liquid-TiO2 nanoparticle modified carbon paste electrode for the voltammetric determination of benserazide in biological samples
    Ensafi, Ali A.
    Bahrami, Hajar
    Rezaei, B.
    Karimi-Maleh, Hassan
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (02): : 831 - 835