Sensitive Voltammetric Determination of Cadmium(II) with 8-Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode

被引:2
|
作者
Jia, Shaohui [1 ]
Gong, Shixing [2 ]
Cheng, Yong [2 ]
Wang, Huiyun [1 ]
Liu, Hejian [2 ]
Zhang, Bo [1 ]
Sun, Wei [2 ]
机构
[1] Jining Med Univ, Sch Pharm, Jining 272100, Peoples R China
[2] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
关键词
8-Hydroxyquinoline; 1-Ethyl-3-methylimidazoliam ethylsulphate; Cadmium; Differential pulse anodic stripping voltammetry; Carbon paste electrode; STRIPPING VOLTAMMETRY; ELECTROCHEMICAL DETECTION; PERIPHERAL-BLOOD; FILM; LEAD(II); ANTIMONY; SPECTROMETRY; EXTRACTION; CHLORIDE; COPPER;
D O I
10.1002/jccs.201400177
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, 8-hydroxyquinoline (HQ) and ionic liquid (IL) modified carbon paste electrode was fabricated and used for the sensitive determination of cadmium(II) with differential pulse anodic stripping voltammetry (DPASV). The modified electrode was prepared by the addition of HQ and IL 1-ethyl-3-methylimidazoliam ethylsulphate as the modifiers into the traditional carbon paste mixture. Cd(II) was preconcentrated and reduced on the surface of the modified electrode at the potential of -1.0 V (vs. SCE) by the co-contributions from the formation of HQ-Cd(II) complex and the accumulation effect of IL. Then the reduced Cd on the electrode surface was reoxidized by DPASV with a sensitive oxidation peak appeared at -0.79 V (vs. SCE). Under the optimal conditions, the oxidation peak current was proportional to the Cd(II) concentration in the range from 0.03 to 2.0 mu mol/L with the detection limit as 5.0 nmol/L (3 sigma). The proposed method was successfully applied to the water samples detection with the recovery in the range from 95.6% to 96.6%.
引用
收藏
页码:1217 / 1222
页数:6
相关论文
共 50 条
  • [21] Voltammetric determination of bisphenol A using modified carbon paste electrode
    Jahani, Peyman Mohammadzadeh
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024,
  • [22] Voltammetric determination of lead (II) ions at carbon paste electrode modified with banana tissue
    Institute of Chemistry, University of the Philippines, Los Baños, Philippines
    J. Appl. Sci., 2007, 9 (1286-1292): : 1286 - 1292
  • [23] Voltammetric determination of cadmium (II) based on a composite film of a thiol-functionalized mesoporous molecular sieve and an ionic liquid
    Guo, Jing
    Luo, Yueping
    Ge, Fei
    Ding, Yonglan
    Fei, Junjie
    MICROCHIMICA ACTA, 2011, 172 (3-4) : 387 - 393
  • [24] Voltammetric Determination of Pb(II) Ions at a Modified Kaolinite-Carbon Paste Electrode
    Akanji, Seyi P.
    Arotiba, Omotayo A.
    Nkosi, Duduzile
    ELECTROCATALYSIS, 2019, 10 (06) : 643 - 652
  • [25] Sensitive Detection of 8-Hydroxyquinoline in Cosmetics by Using a Poly(tannic acid)-Modified Glassy Carbon Electrode
    Gao, Zhimin
    Zeng, Qiang
    Wang, Min
    Wang, Lishi
    CHEMISTRYSELECT, 2022, 7 (16):
  • [26] Sensitive Voltammetric Determination of Methyl Parathion Using a Carbon Paste Electrode Modified with Mesoporous Zirconia
    Tan, Xiaohong
    Li, Buhai
    Zhan, Guoqing
    Li, Chunya
    ELECTROANALYSIS, 2010, 22 (02) : 151 - 154
  • [27] Application of ionic liquid modified carbon ceramic electrode for the sensitive voltammetric detection of rutin
    Zhan, Tianrong
    Sun, Xiaoying
    Wang, Xiuzhen
    Sun, Wei
    Hou, Wanguo
    TALANTA, 2010, 82 (05) : 1853 - 1857
  • [28] Voltammetric behavior and determination of tanshinone II A at carbon paste electrode
    Tian Xinjuan
    Song Junfeng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (09) : 1283 - 1286
  • [29] Determination of Cadmium in Vegetables by Sequential Injection Analysis Method Using 8-Hydroxyquinoline as Complexing Agent
    Chaiyasing, Kanokwan
    Liawruangrath, Boonsom
    Natakankitkul, Surapol
    Satienperakul, Sakchai
    Sirisungworawong, Wasan
    Rannurags, Narabhats
    Liawruangrath, Saisunee
    CHIANG MAI JOURNAL OF SCIENCE, 2019, 46 (02): : 308 - 321
  • [30] Selective and sensitive determination of Cd(II) ions in various samples using a novel modified carbon paste electrode
    Aglan, Refaat F.
    Named, Mostafa M.
    Saleh, Hosam M.
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2019, 10 (1)