Poly(2-amino-4-thiazoleacetic acid)/multiwalled carbon nanotubes modified glassy carbon electrodes for the electrochemical detection of copper(II)

被引:38
作者
Zhao, Hong [1 ]
Jiang, Ying [1 ]
Ma, Yurong [1 ]
Wu, Zhijiao [1 ]
Cao, Qian [1 ]
He, Yujian [1 ]
Li, Xiangjun [1 ]
Yuan, Zhuobin [1 ]
机构
[1] Chinese Acad Sci, Grad Univ, Coll Chem & Chem Engn, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Poly(2-amino-4-thiazoleacetic acid); Multiwalled carbon nanotubes; Copper detection; Differential pulse stripping voltammetry; ATOMIC-ABSORPTION-SPECTROMETRY; VOLTAMMETRIC DETECTION; ION CHROMATOGRAPHY; STRIPPING ANALYSIS; AQUEOUS-SOLUTION; SILICA-GEL; METAL; FILM; ADSORPTION; COMPLEXES;
D O I
10.1016/j.electacta.2009.12.008
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Poly(2-amino-4-thiazoleacetic acid)/multiwalled carbon nanotubes modified glassy carbon electrodes obtained by electropolymerization of 2-amino-4-thiazoleacetic acid. were used for the voltammetric determination of copper ions. The voltammetric response of copper ions at poly(2-amino-4-thiazoleacetic acid)/multiwalled carbon nanotubes modified glassy carbon electrodes was evaluated by differential pulse stripping voltammetry. The peak currents were linearly dependent on the concentrations of the copper ions in the range from 7.0 x 10(-7) M to 5.0 x 10(-5) M, with a coefficiency of 0.9987. The detection limit is 5.0. 10(-10) M calculated for a signal-to-noise ratio of 3 (S/N = 3). And it could be used for the simultaneous determination of copper and cadmium ions. The proposed method was successfully applied to the determination of copper ions in natural water. The concentration of Cu2+ was calculated to be 2.0 x 10(-5) M by standard addition method. The recovery rate was 94%. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2518 / 2521
页数:4
相关论文
共 27 条
[1]   Speciation of iron(II), iron(III) and full-range pH monitoring using paptode: A simple colorimetric method as an appropriate alternative for optodes [J].
Abbaspour, A ;
Mehrgardi, MA ;
Noori, A ;
Kamyabi, MA ;
Khalafi-Nezhad, A ;
Rad, MNS .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) :857-865
[2]   Electrochemical study of the complexes of aspartame with Cu(II), Ni(II) and Zn(II) ions in the aqueous medium [J].
Çakir, S ;
Coskun, E ;
Biçer, E ;
Çakir, O .
CARBOHYDRATE RESEARCH, 2003, 338 (11) :1217-1222
[3]   UV-visible and synchronous fluorescence spectroscopic investigations of the complexation of Al(III) with caffeic acid, in aqueous low acidic medium [J].
Cornard, Jean-Paul ;
Caudron, Alexandra ;
Merlin, Jean-Claude .
POLYHEDRON, 2006, 25 (11) :2215-2222
[4]   An electroanalytical application of 2-aminothiazole-modified silica gel after adsorption and separation of Hg(II) from heavy metals in aqueous solution [J].
Dias Filho, Newton L. ;
do Carmo, Devaney R. ;
Rosa, Andre H. .
ELECTROCHIMICA ACTA, 2006, 52 (03) :965-972
[5]   Voltammetric analysis of Cu(II), Cd(II) and Zn(II) complexes and their cyclic voltammetry with several cephalosporin antibiotics [J].
El-Maali, NA ;
Osman, AH ;
Aly, AAM ;
Al-Hazmi, GAA .
BIOELECTROCHEMISTRY, 2005, 65 (02) :95-104
[6]   Metal and metalloid multi-elementary ICP-MS validation in whole blood, plasma, urine and hair -: Reference values [J].
Goullé, JP ;
Mahieu, L ;
Castermant, J ;
Neveu, N ;
Bonneau, L ;
Lainé, G ;
Bouige, D ;
Lacroix, C .
FORENSIC SCIENCE INTERNATIONAL, 2005, 153 (01) :39-44
[7]   Homocysteine metabolism in families from southern Italy with neural tube defects: role of genetic and nutritional determinants [J].
Grandone, E ;
Corrao, AM ;
Colaizzo, D ;
Vecchione, G ;
Di Girgenti, C ;
Paladini, D ;
Sardella, L ;
Pellegrino, M ;
Zelante, L ;
Martinelli, P ;
Margaglione, M .
PRENATAL DIAGNOSIS, 2006, 26 (01) :1-5
[8]   HELICAL MICROTUBULES OF GRAPHITIC CARBON [J].
IIJIMA, S .
NATURE, 1991, 354 (6348) :56-58
[9]   Anodic stripping voltammetric determination of copper(II) using a functionalized carbon nanotubes paste electrode modified with crosslinked chitosan [J].
Janegitz, Bruno C. ;
Marcolino-Junior, Luiz H. ;
Campana-Filho, Sergio P. ;
Faria, Ronaldo C. ;
Fatibello-Filho, Orlando .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 142 (01) :260-266
[10]   Gold nanoelectrode ensembles for the simultaneous electrochemical detection of ultratrace arsenic, mercury, and copper [J].
Jena, Bikash Kumar ;
Raj, C. Retna .
ANALYTICAL CHEMISTRY, 2008, 80 (13) :4836-4844