Difference in appearance between prone and supine myocardial perfusion images obtained on a high-efficiency cadmium zinc telluride SPECT camera

被引:1
|
作者
Howard, Brandon A. [1 ]
Choudhury, Kingshuk Roy [1 ,2 ]
Oldan, Jorge D. [3 ]
Pagnanelli, Robert A. [1 ]
Borges-Neto, Salvador [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Div Nucl Med, Durham, NC 27710 USA
[2] Duke Univ, Dept Biostat & Bioinformat, Durham, NC 27710 USA
[3] Univ N Carolina, Dept Radiol, Chapel Hill, NC USA
关键词
coronary artery disease; myocardial perfusion imaging; single photon emission computed tomography; solid-state detector; CORONARY-ARTERY-DISEASE; EMISSION COMPUTED-TOMOGRAPHY; MPI; ACQUISITIONS; ANGIOGRAPHY;
D O I
10.1097/MNM.0000000000000476
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveThe recent introduction of high-efficiency solid-state gamma cameras for myocardial perfusion single photon emission computed tomography has enabled lower patient radiation dose, faster imaging, and improved image quality. However, artifacts still complicate interpretation. Prone imaging is a common maneuver to reduce artifacts and increase accuracy for detection of coronary artery disease, but its effect on imaging relative to supine imaging has not been fully characterized in these new systems.MethodsIn this IRB-approved, HIPAA-compliant retrospective study, 30 patients were reviewed, who underwent prone and supine imaging on the GE 530c multipinhole cadmium zinc telluride camera under both rest and stress conditions. Informed consent was waived. Perfusion was scored visually by two readers on a five-point scale according to the 17-segment model. Differences were assessed for significance using a multivariate linear effects model and restricted maximum likelihood method.ResultsProne positioning resulted in increased activity in the basal inferior (P<0.001), basal inferolateral (P=0.009), basal inferoseptal (P<0.001), and mid-inferior (P<0.001) segments when taking into account factors such as stress versus rest, perfusion scores of other segments, and reader.ConclusionProne imaging on the GE 530c camera increases measured tracer activity in the basal inferior, basal inferolateral, basal inferoseptal, and mid-inferior segments. Caution is advised when diagnosing myocardial ischemia in these territories, particularly if clinical data are unavailable. Copyright (C) 2016 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:487 / 492
页数:6
相关论文
共 41 条
  • [31] Reduced acquisition time for thallium myocardial perfusion imaging with large field cadmium-zinc-telluride SPECT/CT cameras: An equivalence study
    Bonnefoy, P. B.
    Janvier, L.
    Arede, C.
    Drouet, C.
    Harami, D.
    Marque, S.
    Ahond-Vionnet, R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (04) : 1933 - 1941
  • [32] Quantitative high-efficiency cadmium-zinc-telluride SPECT with dedicated parallel-hole collimation system in obese patients: Results of a multi-center study
    Nakazato, Ryo
    Slomka, Piotr J.
    Fish, Mathews
    Schwartz, Ronald G.
    Hayes, Sean W.
    Thomson, Louise E. J.
    Friedman, John D.
    Lemley, Mark, Jr.
    Mackin, Maria L.
    Peterson, Benjamin
    Schwartz, Arielle M.
    Doran, Jesse A.
    Germano, Guido
    Berman, Daniel S.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (02) : 266 - 278
  • [33] Real-time breath-hold triggering of myocardial perfusion imaging with a novel cadmium-zinc-telluride detector gamma camera
    Buechel, Ronny R.
    Pazhenkottil, Aju P.
    Herzog, Bernhard A.
    Husmann, Lars
    Nkoulou, Rene N.
    Burger, Irene A.
    Valenta, Ines
    Wyss, Christophe A.
    Ghadri, Jelena R.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) : 1903 - 1908
  • [34] Real-time breath-hold triggering of myocardial perfusion imaging with a novel cadmium-zinc-telluride detector gamma camera
    Ronny R. Buechel
    Aju P. Pazhenkottil
    Bernhard A. Herzog
    Lars Husmann
    René N. Nkoulou
    Irene A. Burger
    Ines Valenta
    Christophe A. Wyss
    Jelena R. Ghadri
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 1903 - 1908
  • [35] Radiation Dose and Prognosis of Ultra-Low-Dose Stress-First Myocardial Perfusion SPECT in Patients with Chest Pain Using a High-Efficiency Camera
    Einstein, Andrew J.
    Johnson, Lynne L.
    DeLuca, Albert J.
    Kontak, Andrew C.
    Groves, Daniel W.
    Stant, Jennifer
    Pozniakoff, Ted
    Cheng, Bin
    Rabbani, Leroy E.
    Bokhari, Sabahat
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (04) : 545 - 551
  • [36] Gated SPECT myocardial perfusion imaging with cadmium-zinc-telluride detectors allows real-time assessment of dobutamine-stress-induced wall motion abnormalities
    Nkoulou, Rene
    Wolfrum, Mathias
    Pazhenkottil, Aju P.
    Fiechter, Michael
    Buechel, Ronny R.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (05) : 1734 - 1742
  • [37] Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography
    Michael Fiechter
    Jelena R. Ghadri
    Silke M. Kuest
    Aju P. Pazhenkottil
    Mathias Wolfrum
    Rene N. Nkoulou
    Robert Goetti
    Oliver Gaemperli
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 2025 - 2030
  • [38] Quantitative High Efficiency SPECT With Cadmium-Zinc-Telluride and Dedicated Parallel Collimation System in Obese Patients: A Result From a Multi-Center Study
    Nakazato, Ryo
    Fish, Mathews
    Schwartz, Ronald G.
    Hayes, Sean W.
    Arsanjani, Reza
    Thomson, Louise E.
    Friedman, John D.
    Mackin, Maria L.
    Peterson, Benjamin
    Schwartz, Arielle M.
    Slomka, Piotr J.
    Berman, Daniel S.
    CIRCULATION, 2013, 128 (22)
  • [39] Diagnostic performance of different cardiac stress protocols for myocardial perfusion imaging for the diagnosis of coronary artery disease using a cadmium-zinc-telluride camera with invasive coronary angiography correlation
    Ochoa-Figueroa, M.
    Frias-Rose, J.
    Good, E.
    Sanchez-Rodriguez, V.
    Davidsson, A.
    Pagonis, C.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2023, 42 (05): : 281 - 288
  • [40] The effect of body mass index on high versus low administered activity protocol myocardial perfusion imaging scan time and effective dose using a cadmium zinc telluride camera in clinical practice
    Prasad, Kalpna
    Adams, Chad C.
    Quang, Eiping
    Taylor, Justin
    Stocker, Derek J.
    WORLD JOURNAL OF NUCLEAR MEDICINE, 2021, 20 (03) : 247 - 252