Difference in appearance between prone and supine myocardial perfusion images obtained on a high-efficiency cadmium zinc telluride SPECT camera

被引:1
|
作者
Howard, Brandon A. [1 ]
Choudhury, Kingshuk Roy [1 ,2 ]
Oldan, Jorge D. [3 ]
Pagnanelli, Robert A. [1 ]
Borges-Neto, Salvador [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Div Nucl Med, Durham, NC 27710 USA
[2] Duke Univ, Dept Biostat & Bioinformat, Durham, NC 27710 USA
[3] Univ N Carolina, Dept Radiol, Chapel Hill, NC USA
关键词
coronary artery disease; myocardial perfusion imaging; single photon emission computed tomography; solid-state detector; CORONARY-ARTERY-DISEASE; EMISSION COMPUTED-TOMOGRAPHY; MPI; ACQUISITIONS; ANGIOGRAPHY;
D O I
10.1097/MNM.0000000000000476
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveThe recent introduction of high-efficiency solid-state gamma cameras for myocardial perfusion single photon emission computed tomography has enabled lower patient radiation dose, faster imaging, and improved image quality. However, artifacts still complicate interpretation. Prone imaging is a common maneuver to reduce artifacts and increase accuracy for detection of coronary artery disease, but its effect on imaging relative to supine imaging has not been fully characterized in these new systems.MethodsIn this IRB-approved, HIPAA-compliant retrospective study, 30 patients were reviewed, who underwent prone and supine imaging on the GE 530c multipinhole cadmium zinc telluride camera under both rest and stress conditions. Informed consent was waived. Perfusion was scored visually by two readers on a five-point scale according to the 17-segment model. Differences were assessed for significance using a multivariate linear effects model and restricted maximum likelihood method.ResultsProne positioning resulted in increased activity in the basal inferior (P<0.001), basal inferolateral (P=0.009), basal inferoseptal (P<0.001), and mid-inferior (P<0.001) segments when taking into account factors such as stress versus rest, perfusion scores of other segments, and reader.ConclusionProne imaging on the GE 530c camera increases measured tracer activity in the basal inferior, basal inferolateral, basal inferoseptal, and mid-inferior segments. Caution is advised when diagnosing myocardial ischemia in these territories, particularly if clinical data are unavailable. Copyright (C) 2016 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:487 / 492
页数:6
相关论文
共 41 条
  • [21] Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography
    Fiechter, Michael
    Ghadri, Jelena R.
    Kuest, Silke M.
    Pazhenkottil, Aju P.
    Wolfrum, Mathias
    Nkoulou, Rene N.
    Goetti, Robert
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (11) : 2025 - 2030
  • [22] The clinical usefulness of phase analysis in detecting coronary artery disease using dipyridamole thallium-201-gated myocardial perfusion imaging with a cadmium-zinc-telluride camera
    Lin, Wan-Ling
    Wang, Shan-Ying
    Shiau, Yu-Chien
    Wu, Yen-Wen
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (01) : 241 - 250
  • [23] The clinical usefulness of phase analysis in detecting coronary artery disease using dipyridamole thallium-201-gated myocardial perfusion imaging with a cadmium-zinc-telluride camera
    Wan-Ling Lin
    Shan-Ying Wang
    Yu-Chien Shiau
    Yen-Wen Wu
    Journal of Nuclear Cardiology, 2020, 27 : 241 - 250
  • [24] Soft tissue attenuation patterns in stress myocardial perfusion SPECT images: A comparison between supine and upright acquisition systems
    Chawla, David
    Rahaby, Mouyyad
    Amin, Amit P.
    Vashistha, Raj
    Alyousef, Tareq
    Martinez, Hector X.
    Doukky, Rami
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (02) : 281 - 290
  • [25] Prognostic Implications of the Difference Between Left Ventricular Ejection Fractions After Stress and at Rest in Addition to the Quantification of Myocardial Perfusion Abnormalities Obtained With Gated SPECT
    Carvalho, Paulo A.
    Aguiar, Paula M.
    Grossman, Gabriel B.
    Moraes, Janaina F.
    Baptista, Ilo S.
    Hirakata, Vania N.
    Ludwig, Roberto T. F.
    Ludwig, Eduardo B.
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (08) : 748 - 754
  • [26] Relationships between myocardial perfusion abnormalities and poststress left ventricular functional impairment on cadmium-zinc-telluride imaging
    Alessia Gimelli
    Riccardo Liga
    Assuero Giorgetti
    Annette Kusch
    Emilio Maria Pasanisi
    Paolo Marzullo
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 994 - 1003
  • [27] Reduction in Occupational and Patient Radiation Exposure from Myocardial Perfusion Imaging: Impact of Stress-Only Imaging and High-Efficiency SPECT Camera Technology
    Duvall, W. Lane
    Guma, Krista A.
    Kamen, Jacob
    Croft, Lori B.
    Parides, Michael
    George, Titus
    Henzlova, Milena J.
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (08) : 1251 - 1257
  • [28] Reduced acquisition time for thallium myocardial perfusion imaging with large field cadmium-zinc-telluride SPECT/CT cameras: An equivalence study
    P. B. Bonnefoy
    L. Janvier
    C. Arede
    C. Drouet
    D. Harami
    S. Marque
    R. Ahond-Vionnet
    Journal of Nuclear Cardiology, 2022, 29 : 1933 - 1941
  • [29] A machine learning-based approach to directly compare the diagnostic accuracy of myocardial perfusion imaging by conventional and cadmium-zinc telluride SPECT
    Valeria Cantoni
    Roberta Green
    Carlo Ricciardi
    Roberta Assante
    Emilia Zampella
    Carmela Nappi
    Valeria Gaudieri
    Teresa Mannarino
    Andrea Genova
    Giovanni De Simini
    Alessia Giordano
    Adriana D’Antonio
    Wanda Acampa
    Mario Petretta
    Alberto Cuocolo
    Journal of Nuclear Cardiology, 2022, 29 : 46 - 55
  • [30] Quantitative high-efficiency cadmium-zinc-telluride SPECT with dedicated parallel-hole collimation system in obese patients: Results of a multi-center study
    Ryo Nakazato
    Piotr J. Slomka
    Mathews Fish
    Ronald G. Schwartz
    Sean W. Hayes
    Louise E. J. Thomson
    John D. Friedman
    Mark Lemley
    Maria L. Mackin
    Benjamin Peterson
    Arielle M. Schwartz
    Jesse A. Doran
    Guido Germano
    Daniel S. Berman
    Journal of Nuclear Cardiology, 2015, 22 : 266 - 275