Initial stability of ankle arthrodesis with three-screw fixation.: A finite element analysis

被引:37
作者
Alonso-Vázquez, A
Lauge-Pedersen, H
Lidgren, L
Taylor, M
机构
[1] Univ Southampton, Bioengn Sci Res Grp, Sch Engn Sci, Southampton SO17 1BJ, Hants, England
[2] Univ Lund Hosp, Dept Orthopaed, S-22185 Lund, Sweden
关键词
ankle arthrodesis; internal fixation; finite element; initial stability; micromotions; cancellous screws;
D O I
10.1016/j.clinbiomech.2004.04.014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Compare the initial stability at the fusion site of ankle arthrodesis fixed with two and three screws. Design. Finite element models of ankle arthrodesis were developed from computed tomography images. Two-screw constructs were augmented with a third screw in different orientations and Subjected to loads likely to affect the ankle postoperatively. Background More stable fixation seems to increase the chance of fusion, as it minimises the motion between the tibiotalar interfaces. Methods. Non-linear elastic finite element analyses were performed in external torsion and dorsiflexion. The micromotions at the tibiotalar interface were computed to compare the two- and three-screw fixation in intact and flat-cut arthrodesis. Results. Adding a third screw reduced the micromotions at the fusion site. Inserting the third screw anteriorly predicted lower peak micromotions than inserting the screw posteriorly, except for the intact arthrodesis tested in dorsiflexion. Three-screw intact arthrodesis predicted lower peak micromotions than flat-cut arthrodesis. Conclusions. Better stability was predicted for three-screw ankle arthrodesis. In flat-cut arthrodesis, a third screw inserted anteriorly performed better than a posterior screw. In intact arthrodesis, a posterior screw seemed a better option when flexion stability was the main concern. Even with three-screw fixation, the configuration of the first two-crossed screws may still be important to improve the stability at the fusion site. Relevance The optimal number and placement of screws in ankle arthrodesis has yet to be determined. The differences in stability predicted between various screw configurations and Surface preparation techniques presented here may be the difference between success and failure. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:751 / 759
页数:9
相关论文
共 29 条
[1]  
Abidi N A, 2000, J Am Acad Orthop Surg, V8, P200
[2]  
[Anonymous], 1998, FOOT, DOI DOI 10.1016/S0958-2592(98)90035-9
[3]   Outcome of ankle arthrodesis performed by dowel technique in patients with rheumatic disease [J].
Belt, EA ;
Mäenpää, H ;
Lehto, MUK .
FOOT & ANKLE INTERNATIONAL, 2001, 22 (08) :666-669
[4]   Ankle arthrodesis with cross-screw fixation - Good results in 36/40 cases followed 3-7 years [J].
Chen, YJ ;
Huang, TJ ;
Shih, HN ;
Hsu, KY ;
Hsu, RWW .
ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (05) :473-478
[5]  
Demetriades L, 1998, CLIN ORTHOP RELAT R, P28
[6]  
Dereymaeker GP, 1998, CLIN ORTHOP RELAT R, P43
[7]  
DESTRESSE B, 1995, INNOV TECH BIOL MED, V16, P288
[8]   PRIMARY UNION OF ANKLE ARTHRODESIS - REVIEW OF A SINGLE INSTITUTION MULTIPLE SURGEON EXPERIENCE [J].
DOHM, M ;
PURDY, BA ;
BENJAMIN, J .
FOOT & ANKLE INTERNATIONAL, 1994, 15 (06) :293-296
[9]  
Easley Mark E, 2002, J Am Acad Orthop Surg, V10, P157
[10]   BIOLOGIC AND BIOMECHANIC EVALUATION OF POSTERIOR LUMBAR FUSION IN THE RABBIT - THE EFFECT OF FIXATION RIGIDITY [J].
FEIGHAN, JE ;
STEVENSON, S ;
EMERY, SE .
SPINE, 1995, 20 (14) :1561-1567