Effect of filtrate flux and process disruptions on virus retention by a relatively homogeneous virus removal membrane

被引:11
作者
Afzal, Mohammad A. [1 ]
Zydney, Andrew L. [1 ]
机构
[1] Penn State Univ, Dept Chem Engn, University Pk, PA 16802 USA
基金
美国国家科学基金会;
关键词
monoclonal antibody; process disruption; virus filtration; virus retention; PRESSURE RELEASE;
D O I
10.1002/btpr.3255
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Recent studies have shown that virus retention by specific virus filters can be reduced at low flow rates and after process disruptions; however, the magnitude of these changes in virus retention and the underlying mechanisms controlling this behavior are still not well understood. The objective of this study was to develop a quantitative understanding of the factors controlling the virus retention behavior of a relatively homogeneous polyvinylidene fluoride virus removal filter. Data were obtained with the bacteriophage phi X174 as a model virus. Virus retention decreased as the filtrate flux was reduced and also declined slightly over the course of the virus filtration. Virus retention immediately after a process disruption decreased by as much as a factor of 1000 (3-logs) depending on the duration and timing of the disruption. The experimental results were well-described using an internal polarization model that accounts for accumulation and release of virus during the filtration / disruption, with the key model parameters dependent on the filtrate flux. These results provide important insights into the factors controlling the virus retention behavior as well as guidelines for the effective use of virus removal filters in bioprocessing.
引用
收藏
页数:8
相关论文
共 18 条
[1]   Normal-flow virus filtration: detection and assessment of the endpoint in bioprocessing [J].
Bolton, G ;
Cabatingan, M ;
Rubino, M ;
Lute, S ;
Brorson, K ;
Bailey, M .
BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2005, 42 :133-142
[2]   Continuous viral filtration for the production of monoclonal antibodies [J].
David, Laura ;
Niklas, Jens ;
Budde, Bastian ;
Lobedann, Martin ;
Schembecker, Gerhard .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2019, 152 :336-347
[3]   Effects of solution conditions on virus retention by the Viresolve® NFP filter [J].
Dishari, Shudipto K. ;
Micklin, Matthew R. ;
Sung, Ki-Joo ;
Zydney, Andrew L. ;
Venkiteshwaran, Adith ;
Earley, Jennifer N. .
BIOTECHNOLOGY PROGRESS, 2015, 31 (05) :1280-1286
[4]   Probing effects of pressure release on virus capture during virus filtration using confocal microscopy [J].
Dishari, Shudipto K. ;
Venkiteshwaran, Adith ;
Zydney, Andrew L. .
BIOTECHNOLOGY AND BIOENGINEERING, 2015, 112 (10) :2115-2122
[5]  
EMEA, 2001, NOT GUID PLASM DER M
[6]   The effects of flux on the clearance of minute virus of mice during constant flux virus filtration [J].
Fan, Rong ;
Namila, Fnu ;
Sansongko, Davar ;
Wickramasinghe, S. Ranil ;
Jin, Mi ;
Kanani, Dharmesh ;
Qian, Xianghong .
BIOTECHNOLOGY AND BIOENGINEERING, 2021, 118 (09) :3511-3521
[7]   Internal Virus Polarization Model for Virus Retention by the Ultipor® VF Grade DV20 Membrane [J].
Jackson, Nigel B. ;
Bakhshayeshi, Meisam ;
Zydney, Andrew L. ;
Mehta, Amit ;
van Reis, Robert ;
Kuriyel, Ralf .
BIOTECHNOLOGY PROGRESS, 2014, 30 (04) :856-863
[8]  
Kiss Robert D, 2011, PDA J Pharm Sci Technol, V65, P715, DOI 10.5731/pdajpst.2011.00852
[9]  
Lacasse D., 2013, BIOPROCESS INT, V11, P34
[10]   Mechanistic failure mode investigation and resolution of parvovirus retentive filters [J].
LaCasse, Daniel ;
Lute, Scott ;
Fiadeiro, Marcus ;
Basha, Jonida ;
Stork, Matthew ;
Brorson, Kurt ;
Godavarti, Ranga ;
Gallo, Chris .
BIOTECHNOLOGY PROGRESS, 2016, 32 (04) :959-970