Optimisation procedure for the inhibitive determination of chromium(III) using an amperometric tyrosinase biosensor

被引:33
作者
Renedo, OD [1 ]
Lomillo, MAA [1 ]
Martinez, MJA [1 ]
机构
[1] Univ Burgos, Dept Quim, Area Quim Analit, Fac Ciencias, E-09001 Burgos, Spain
关键词
tyrosinase; biosensor; chromium; experimental design;
D O I
10.1016/j.aca.2004.06.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enzymatic amperometric procedure for measurement of chromium(III), based on the inhibitive action of this metal on tyrosinase enzyme activity, was developed for this purpose. A glassy carbon electrode was used as a support for the electropolymerisation of a polypyrrole (PPy) film, in which tyrosinase was immobilised. The parameters were optimised using experimental design methodology. To determine the optimum conditions and the influence of the factors in the experiment, a canonical analysis of the response surface was carried out. Under these conditions, the repeatability (R.S.D. < 5.8%), the reproducibility (R.S.D. < 8.3%), and the stability of the modified electrode were all analysed. The detection limit for Cr(III) was calculated at a value of 5.0 x 10(-7) mol dm(-3) with a relative standard deviation (R.S.D.) of 5.8%. Analysis of the possible effect of the presence of foreign ions in the solution was performed. The method was applied to determine levels of chromium(III) in spiked urine samples, in the waste water from a tannery, and in river water from an industrial area. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 26 条
[1]   Optimization of the experimental parameters in the determination of rifamycin SV by adsorptive stripping voltammetry [J].
Alonso, MA ;
Sanllorente, S ;
Sarabia, LA ;
Arcos, MJ .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :123-133
[2]  
[Anonymous], [No title captured]
[3]  
[Anonymous], 1987, BASIC INORGANIC CHEM
[4]  
Berman E, 1980, Toxic metals and their analysis
[5]   Flow injection analysis of mercury(II) in pharmaceuticals based on enzyme inhibition and biosensor detection [J].
Bertocchi, P ;
Ciranni, E ;
Compagnone, D ;
Magearu, V ;
Palleschi, G ;
Pirvutoiu, S ;
Valvo, L .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) :263-269
[6]  
Box G, 1987, EMPIRICAL MODEL BUIL
[7]  
Box G.E.P., 1989, ESTADISTICA INVESTIG
[8]   BIOCATALYSIS WITH POLYPHENOL OXIDASE - A REVIEW [J].
BURTON, SG .
CATALYSIS TODAY, 1994, 22 (03) :459-487
[9]   Determination of molybdenum, chromium and aluminium in human urine by electrothermal atomic absorption spectrometry using fast-programme methodology [J].
Campillo, N ;
Viñas, P ;
López-García, I ;
Hernández-Córdoba, M .
TALANTA, 1999, 48 (04) :905-912
[10]   Disposable tyrosinase-peroxidase bi-enzyme sensor for amperometric detection of phenols [J].
Chang, SC ;
Rawson, K ;
McNeil, CJ .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1015-1023