Simultaneous in-situ extraction and electrochemical detection of antidepressant drug imipramine and its active metabolite in human biofluid samples

被引:6
作者
Karikalan, Natarajan [1 ,2 ]
Sundaresan, Periyasamy [1 ,2 ]
Na, Jun-Hee [2 ]
Lee, Tae Yoon [1 ,2 ,3 ,4 ]
机构
[1] Chungnam Natl Univ, Dept Biomed Engn, Daejeon 34134, South Korea
[2] Chungnam Natl Univ, Dept Elect Elect & Commun Engn Educ, Daejeon 34134, South Korea
[3] Chungnam Natl Univ, Dept Technol Educ, Daejeon 34134, South Korea
[4] Chungnam Natl Univ, Dept Convergence Syst Engn, Dept Technol Educ, Daejeon 34134, South Korea
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2022年 / 365卷
基金
新加坡国家研究基金会;
关键词
Therapeutic drug monitoring; Personalized dosing; Plasma protein; Drug extraction; Electrochemical detection; HUMAN SERUM-ALBUMIN; TRICYCLIC ANTIDEPRESSANTS; DESIPRAMINE; CHROMATOGRAPHY; PLASMA;
D O I
10.1016/j.snb.2022.131960
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The rapidly advancing modern healthcare system necessitates the development of cutting-edge technologies for therapeutic drug monitoring. Protein-bound drugs challenge the rapid quantification of analytical methods that require additional separation and cleanup processes, which delay the development of point-of-care testing platform. Here, a human serum albumin (HSA)/iron molybdate (FeM;Fe-2(MoO4)(3))/reduced graphene oxide (rGO) is reported for the in-situ extraction and determination of imipramine (IMP) drug and its active metabolite desipramine (DMP) in human serum and plasma samples. HSA was used for the extraction of drugs from the complex plasma proteins, and the extracted drugs were directly detected by FeM/rGO without additional sample cleanup. The developed sensor, which was optimized for the drug therapeutic window under normal conditions, exhibited a linear range of 10-756 ng/mL as well as a remarkable limit of detection and sensitivity of approximately 4 +/- 2 ng/mL and 0.0124 +/- 0.0003 mu A cm(-2 )ng(-1) mL, respectively, for IMP-DMP. The spike-and recovery method was used to validate the developed sensor in real sample analysis. Based on the results, the sensing mechanism was elucidated: protein-protein interaction facilitates drug transportation from the plasma protein to electrode surface. Thereby, the HSA-FeM/rGO modified electrode recovered more drugs in biofluids compared with HSA unmodified electrode.
引用
收藏
页数:9
相关论文
共 33 条
  • [1] Comparison of different serum sample extraction methods and their suitability for mass spectrometry analysis
    Alshammari, Thamir M.
    Al-Hassan, Ahmed Ali
    Hadda, Taibi B.
    Aljofan, Mohamad
    [J]. SAUDI PHARMACEUTICAL JOURNAL, 2015, 23 (06) : 689 - 697
  • [2] BAILEY DN, 1978, AM J PSYCHIAT, V135, P1325
  • [3] Determination of basic drugs of abuse in human serum by online extraction and LC-MS/MS
    Bouzas, Nerea Ferreiros
    Dresen, Sebastian
    Munz, Barbara
    Weinmann, Wolfgang
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (08) : 2499 - 2507
  • [4] A rapid and reliable method for the quantitation of tricyclic antidepressants in serum using HPLC-MS/MS
    Breaud, Autumn R.
    Harlan, Robert
    Kozak, Marta
    Clarke, William
    [J]. CLINICAL BIOCHEMISTRY, 2009, 42 (12) : 1300 - 1307
  • [5] CRAMMER JL, 1969, PSYCHOPHARMACOLOGIA, V15, P207
  • [6] Adsorptive Stripping Voltammetric Determination of Imipramine and Amitriptiline at a Nanoclay Composite Carbon Ionic Liquid Electrode
    Eslami, E.
    Farjami, F.
    Azar, P. Aberoomand
    Tehrani, M. Saber
    [J]. ELECTROANALYSIS, 2014, 26 (02) : 424 - 431
  • [7] CARDIAC ABNORMALITIES IN POISONING WITH TRICYCLIC ANTIDEPRESSANTS
    FREEMAN, JW
    MUNDY, GR
    BEATTIE, RR
    RYAN, C
    [J]. BRITISH MEDICAL JOURNAL, 1969, 2 (5657) : 610 - &
  • [8] Electrochemical detection of tricyclic antidepressant drugs by HPLC using highly boron-doped diamond electrodes
    Ivandini, TA
    Sarada, BV
    Terashima, C
    Rao, TN
    Tryk, DA
    Ishiguro, H
    Kubota, Y
    Fujishima, A
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 521 (1-2) : 117 - 126
  • [9] Some practical considerations for linearity assessment of calibration curves as function of concentration levels according to the fitness-for-purpose approach
    Jurado, J. M.
    Alcazar, A.
    Muniz-Valencia, R.
    Ceballos-Magana, S. G.
    Raposo, F.
    [J]. TALANTA, 2017, 172 : 221 - 229
  • [10] Studies on the sonochemical polymorphism of Sb2O3 on activated graphite for the electrochemical determination of imipramine
    Karikalan, Natarajan
    Elavarasan, Munirathinam
    Yang, Thomas C. K.
    [J]. ULTRASONICS SONOCHEMISTRY, 2020, 64