External electrical cardioversion in patients with cardiac implantable electronic devices: Is it safe and is immediate device interrogation necessary?

被引:6
|
作者
Pluymaekers, Nikki A. H. A. [1 ]
Dudink, Elton A. M. P. [1 ]
Boersma, Lucas [2 ]
Erkuner, Omer [1 ]
Gelissen, Marloes [1 ]
van Dijk, Vincent [2 ]
Wijffels, Maurits [2 ]
Trang Dinh [1 ]
Vernooy, Kevin [1 ]
Crijns, Harry J. G. M. [1 ]
Balt, Jippe [2 ]
Luermans, Justin G. L. M. [1 ]
机构
[1] MUMC, Dept Cardiol, Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
[2] St Antonius Hosp, Dept Cardiol, Nieuwegein, Netherlands
来源
关键词
CIED; external ECV; immediate device interrogation; safety; ATRIAL-FIBRILLATION; EUROPEAN-SOCIETY; TASK-FORCE; PACEMAKER; DEFIBRILLATION; GUIDELINES; MANAGEMENT;
D O I
10.1111/pace.13467
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundAtrial tachyarrhythmias are common in patients with cardiac implantable electronic devices (CIEDs). Restoration of sinus rhythm by external electrical cardioversion (eECV) is frequently used to alleviate symptoms and to ensure optimal device function. ObjectivesTo evaluate the safety of eECV in patients with contemporary CIEDs and to assess the need for immediate device interrogation after eECV. MethodsWe conducted a retrospective observational study of 229 patients (27.9% female, age 6910 years) with a CIED (104 pacemakers, 69 implantable cardioverter defibrillators, and 56 biventricular devices) who underwent eECV between 2008 and 2016 in two centers. Data from device interrogation before eECV, immediately afterwards, and at first follow-up (FU) after eECV were collected. CIED-related complications and adverse events during and after eECV were recorded. ResultsNo significant differences between right atrial (RA) and right ventricular (RV) sensing or threshold values before eECV, immediately afterwards, or at FU were observed. A small yet significant decrease was observed in RA and RV impedance immediately after eECV (484 vs 462, P<0.001 and 536 vs 514, P<0.001, respectively). The RV impedance did not recover to the baseline value (538 vs 527 , P=0.02). The impedance changes were without clinical consequences. No changes in left ventricular lead threshold or impedance values were measured. No CIED-related complications or adverse events were documented following eECV. ConclusioneECV in patients with contemporary CIEDs is safe. There seems to be no need for immediate device interrogation after eECV.
引用
收藏
页码:1336 / 1340
页数:5
相关论文
共 50 条
  • [31] COMPLICATIONS OF CARDIAC IMPLANTABLE ELECTRONIC DEVICE INTERVENTION IN PATIENTS WITH LEFT VENTRICULAR ASSIST DEVICES
    Kiani, Soroosh
    Merchant, Faisal
    Hoskins, Michael
    Cole, Robert T.
    Black, George
    Lloyd, Michael
    Westerman, Stacy
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 485 - 485
  • [32] Complications of cardiac implantable electronic device intervention in patients with left ventricular assist devices
    Kiani, S.
    Black, G. B.
    Lloyd, M. S.
    Merchant, F. M.
    El-Chami, M. F.
    Cole, R. T.
    Hoskins, M. H.
    Westerman, S. B.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1826 - 1826
  • [33] Electromagnetic Interference in Cardiac Implantable Electronic Devices Is the Use of Smartphones Safe?
    Lennerz, Carsten
    Pavaci, Herribert
    Grebmer, Christian
    Semmler, Verena
    Bourier, Felix
    Haller, Bernhard
    Reents, Tilko
    Hessling, Gabriele
    Deisenhofer, Isabel
    Kolb, Christof
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (01) : 108 - 110
  • [34] ROUTINE CARDIAC IMPLANTABLE ELECTRONIC DEVICE CHECKS ARE NOT REQUIRED AFTER DIRECT CURRENT CARDIOVERSION
    Stodart, Clare
    Wiles, Benedict
    Banks, Phillip
    Mackay, Sian
    Paisey, John
    HEART, 2020, 106 : A54 - A54
  • [35] Postmortem interrogation of cardiac implantable electrical devices may clarify time and cause of death
    Riesinger, Lisa
    Fichtner, S.
    Schuhmann, C. G.
    Estner, H. L.
    Czermak, T.
    Graw, M.
    Fischer, F.
    Lackermair, K.
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2019, 133 (03) : 883 - 888
  • [36] Safety of electronic massagers in patients with cardiac implantable electronic devices
    Chia, Pow-Li
    Mok, Kwang-How
    Wong, Shiun Woei
    Foo, David
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (01): : 167 - 170
  • [37] Postmortem interrogation of cardiac implantable electrical devices may clarify time and cause of death
    Lisa Riesinger
    S. Fichtner
    C. G. Schuhmann
    H. L. Estner
    T. Czermak
    M. Graw
    F. Fischer
    K. Lackermair
    International Journal of Legal Medicine, 2019, 133 : 883 - 888
  • [38] Performance of a remote interrogation system for the in-hospital evaluation of cardiac implantable electronic devices
    Mittal, Suneet
    Younge, Kevin
    King-Ellison, Kelly
    Hammill, Eric
    Stein, Kenneth
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 46 (02) : 121 - 128
  • [39] Performance of a remote interrogation system for the in-hospital evaluation of cardiac implantable electronic devices
    Suneet Mittal
    Kevin Younge
    Kelly King-Ellison
    Eric Hammill
    Kenneth Stein
    Journal of Interventional Cardiac Electrophysiology, 2016, 46 : 121 - 128
  • [40] Remote interrogation and reprogramming of cardiac implantable electronic devices using a custom multivendor solution
    Ploux, Sylvain
    Strik, Marc
    Demoniere, Fabrice
    Rakotoarimanana, Dominique
    Zemmoura, Adlane
    Deplagne, Antoine
    Haissaguerre, Michel
    Varma, Niraj
    Bordachar, Pierre
    HEART RHYTHM, 2023, 20 (04) : 547 - 551