Assessment on R-410A saturated flow boiling heat transfer subject to periodic oscillating heat flux inside an annular duct

被引:4
|
作者
Li, Wen-Ken [1 ]
Hsu, Shu-Hao [2 ]
Lin, Tsing-Fa [2 ]
Chen, Chien-An [2 ,3 ]
Yan, Wei-Mon [4 ,5 ]
机构
[1] Chung Yuan Christian Univ, Dept Mech Engn, Taoyuan 32023, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Dept Mech Engn, Hsinchu 30010, Taiwan
[3] E One MOLI Energy Corp, Dept Res & Dev, Tainan 74144, Taiwan
[4] Natl Taipei Univ Technol, Res Ctr Energy Conservat New Generat Residential, Commercial & Ind Sect, Taipei 10608, Taiwan
[5] Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 10608, Taiwan
关键词
Saturated flow boiling; Oscillating heat flux; Mass flux; Flow patterns; Intermittent boiling flow; BUBBLE CHARACTERISTICS; CONVECTION; FLUIDS; MICROCHANNEL; EQUATIONS; MAP;
D O I
10.1016/j.ijthermalsci.2022.107625
中图分类号
O414.1 [热力学];
学科分类号
摘要
The objective of this study is concerned with assessing experimentally the heat transfer of time-dependent saturated flow boiling (TDSFB) for refrigerant R-410 A stemming from oscillations in the heat flux inside an annular duct with the gap of delta = 2 mm in order to improve the energy efficiency of heat exchanger system. The influences of operating parameters, such as mean applied heat flux q, heat flux oscillation amplitude Delta q/q, mass flux of refrigerant G, oscillation period tp, and saturation temperature Tsat, on heat transfer characteristics of TDSFB are systematically explored. From the present experimental results, it is found that increasing mean applied heat flux enhances the average wall superheat and boiling heat transfer coefficient (BHTC, hr); while an increase in either Delta q/q or tp exerts very minor influence on the boiling curve and hr. As the q oscillates in the triangular waveform, the wall temperature (Tw) varies in sinusoidal waves at the same frequency of q. At low, intermediate, and high q, three different flow patterns versus time are observed and named single-phase flow (SPF), intermittent boiling flow (IBF), and persistent boiling flow (PBF). The oscillation amplitudes of Tw and hr are increased with the increases of Delta q/q. Enhancing either G or Tsat tends to result in a slight decrease in Tw, but an increase in hr. Moreover, the Tw does not fluctuate with the oscillation of lower q under a shorter tp due to the tube thermal inertia, but oscillates significantly as the tp is raised. Finally, a correlation equation is presented to identify the bounds, distinguishing the three different flow patterns of R-410 A TDSFB subject to oscillatory heat flux inside horizontal annuli.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Effect on boiling heat transfer of horizontal smooth minichannel for R-410A and R-407C
    Kwang-II Choi
    A. S. Pamitran
    Jong-Taek Oh
    Hoo-Kyu Oh
    Journal of Mechanical Science and Technology, 2005, 19 : 156 - 163
  • [22] Unsteady phenomena in saturated flow boiling heat transfer - An experimental study on oscillating refrigerant mass flux
    Li, Wen-Ken
    Wang, Y. J.
    Lin, T. F.
    Chen, Bo-Lin
    Chen, C. A.
    Yan, Wei-Mon
    ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (03) : 2430 - 2442
  • [23] Effect of Flow Direction for the Heat Transfer Performance of Refrigerant R-410A Evaporation in a Plate Heat Exchanger
    Yang, Chien-Yuh
    Lin, Yueh-Hung
    Lin, Fu-Chen
    HEAT TRANSFER ENGINEERING, 2013, 34 (13) : 1133 - 1139
  • [24] On the Assessment of Unsteady Evaporation Heat Transfer due to Oscillating Flow Rate in a Narrow Annular Duct
    Li, Wen-Ken
    Shiung, H. J.
    Lin, T. F.
    Chen, C. A.
    Yan, Wei-Mon
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 184
  • [25] Bubble characteristics in time periodic saturated flow boiling of R-134a in a narrow annular pipe due to heat flux oscillation
    Chen, C. A.
    Lin, T. F.
    Yan, Wei-Mon
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 102 : 1150 - 1158
  • [26] Evaporation heat transfer and pressure drop of refrigerant R-410A flow in a vertical plate heat exchanger
    Hsieh, YY
    Lin, TF
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2003, 125 (05): : 852 - 857
  • [27] Study on heat transfer and bubble behavior inside horizontal annuli: Experimental comparison of R-134a, R-407C, and R-410A subcooled flow boiling
    Chen, C. A.
    Li, K. W.
    Lin, T. F.
    Li, Wen-Ken
    Yan, Wei-Mon
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 24
  • [28] Subcooled flow boiling heat transfer of R-134a and bubble characteristics in a horizontal annular duct
    Yin, CP
    Yan, YY
    Lin, TF
    Yang, BC
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2000, 43 (11) : 1885 - 1896
  • [29] Saturated flow boiling heat transfer and critical heat flux in small horizontal flattened tubes
    Tibirica, Cristiano Bigonha
    Ribatski, Gherhardt
    Thome, John Richard
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (25-26) : 7873 - 7883
  • [30] Convective boiling heat transfer of R410A
    School of Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
    Huagong Xuebao, 2006, 10 (2289-2292):