A comparison of hydroxyapatite-coated, titanium-coated, and uncoated tapered external-fixation pins -: An in vivo study in sheep

被引:88
作者
Moroni, A [1 ]
Toksvig-Larsen, S [1 ]
Maltarello, MC [1 ]
Orienti, L [1 ]
Stea, S [1 ]
Giannini, S [1 ]
机构
[1] Univ Bologna, Rizzoli Orthopaed Inst, Dept Orthopaed Surg, I-40136 Bologna, Italy
关键词
D O I
10.2106/00004623-199804000-00011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Three types of surfaces for external fixation pins were compared. One hundred and eight stainless-steel tapered 5/6-millimeter pins were divided into three groups: thirty-six pins remained uncoated (Group A), thirty-six were plasma-sprayed with hydroxyapatite (Group B), and thirty-six were plasma-sprayed with titanium (Group C), The pins were implanted in the left tibia of eighteen sheep, with each sheep receiving six pins from the same group, A unilateral fixator then was assembled on the pins. The medial aspect of the mid-part of the tibial diaphysis was exposed, and a five-millimeter-long cylinder of bone was removed so that load would be borne by the bone-pin interfaces. Six weeks after the procedure, radiographs demonstrated rarefaction of twenty-nine pin tracks in Group A, fifteen in Group B, and thirty in Group C (p = 0.021 for Group A compared with Group B and p = 0.016 for Group B compared with Group C), The mean final insertion torque land standard deviation) was 4360 +/- 1050 newton-millimeters in Group A, 3420 +/- 676 newton-millimeters in Group B, and 3740 +/- 643 newton-millimeters in Group C, With the numbers available, no significant differences could be detected among these values. The mean extraction torque was 253 +/- 175 newton-millimeters in Group A, 3360 +/- 1260 newton-millimeters in Group B, and 1720 +/- 1030 newton-millimeters in Group C (p = 0.002 for Group A compared with Group B, p = 0.017 for Group A compared with Group C, and p = 0.03 for Group B compared with Group C), The extraction torque was significantly lower than the corresponding insertion torque in both Group A (p < 0.001) and Group C (p = 0.003); no significant difference could be found, with the numbers available, in Group B (hydroxyapatite-coated pins), At sixty times magnification, direct contact was seen along a mean of 16 +/- 9 per cent of the bone-pin interface in Group A, 30 +/- 12 per cent of the interface in Group B, and 28 +/- 15 per cent of the interface in Group C (p = 0.042 for Group A compared with Group C), However, at 10,000 times magnification, direct bone-pin contact was found only in Group B. CLINICAL RELEVANCE: The better fixation and greater interface strength of the hydroxyapatite-coated tapered pins should lead to a substantial decrease in the frequency of loosening and infection and consequently to a remarkable improvement in the clinical results of external fixation.
引用
收藏
页码:547 / 554
页数:8
相关论文
共 18 条
[1]   CORTICAL BONE REACTIONS AT THE INTERFACE OF EXTERNAL FIXATION HALF-PINS UNDER DIFFERENT LOADING CONDITIONS [J].
ARO, HT ;
MARKEL, MD ;
CHAO, EYS .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 35 (05) :776-785
[2]   INCREASE OF STABILITY IN EXTERNAL FRACTURE FIXATION BY HYDROXYAPATITE-COATED BONE SCREWS [J].
AUGAT, P ;
CLAES, L ;
HANSELMANN, KF ;
SUGER, G ;
FLEISCHMANN, W .
JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (02) :99-104
[3]  
Caja VL, 1996, CLIN ORTHOP RELAT R, P269
[4]  
COOK SD, 1991, CLIN ORTHOP RELAT R, P280
[5]   THE TREATMENT OF FRACTURES WITH A DYNAMIC AXIAL FIXATOR [J].
DEBASTIANI, G ;
ALDEGHERI, R ;
BRIVIO, LR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (04) :538-545
[6]  
EDWARDS CC, 1986, COMPLICATIONS ORTHOP, V1, P103
[7]  
GEESINK RGT, 1990, CLIN ORTHOP RELAT R, P39
[8]   CHRONIC OSTEOMYELITIS IN PIN TRACKS [J].
GREEN, SA ;
RIPLEY, MJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (07) :1092-1098
[9]   COMPARISON OF THE EFFECTS OF COMPRESSION PLATES AND EXTERNAL FIXATORS ON EARLY BONE-HEALING [J].
LEWALLEN, DG ;
CHAO, EYS ;
KASMAN, RA ;
KELLY, PJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (07) :1084-1091
[10]   BONE INGROWTH ANALYSIS AND INTERFACE EVALUATION OF HYDROXYAPATITE-COATED VERSUS UNCOATED TITANIUM POROUS BONE IMPLANTS [J].
MORONI, A ;
CAJA, VL ;
SABATO, C ;
EGGER, EL ;
GOTTSAUNERWOLF, F ;
CHAO, EYS .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (6-7) :411-416