Reliability and validity of using the Lokomat to assess lower limb joint position sense in people with incomplete spinal cord injury

被引:41
作者
Domingo, Antoinette [1 ,2 ]
Lam, Tania [1 ,2 ]
机构
[1] Univ British Columbia, Sch Kinesiol, Vancouver, BC V5Z 1M9, Canada
[2] Int Collaborat Repair Discoveries ICORD, Vancouver, BC, Canada
基金
加拿大健康研究院;
关键词
PROPRIOCEPTION; HIP; KNEE; INDEPENDENCE; PATIENT; WALKING; STROKE; ANKLE; SWAY;
D O I
10.1186/1743-0003-11-167
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Proprioceptive sense (knowing where the limbs are in space) is critical for motor control during posture and walking, and is often compromised after spinal cord injury (SCI). The purpose of this study was to assess the reliability and validity of using the Lokomat, a robotic exoskeleton used for gait rehabilitation, to quantitatively measure static position sense of the legs in persons with incomplete SCI. Methods: We used the Lokomat and custom software to assess static position sense in 23 able-bodied (AB) subjects and 23 persons with incomplete SCI (American Spinal Injury Association Impairment Scale level B, C or D). The subject's leg was placed into a target position (joint angle) at either the hip or knee and asked to memorize that position. The Lokomat then moved the test joint to a "distractor" position. The subject then used a joystick controller to bring the joint back into the memorized target position. The final joint angle was compared to the target angle and the absolute difference was recorded as an error. All movements were passive. Known-groups validity was determined by the ability of the measure to discriminate between able-bodied and SCI subjects. To evaluate test-retest reliability, subjects were tested twice and intra-class correlation coefficients comparing errors from the two sessions were calculated. We also performed a traditional clinical test of proprioception in subjects with SCI and compared these scores to the robotic assessment. Results: The robot-based assessment test was reliable at the hip and knee in persons with SCI (P <= 0.001). Hip and knee angle errors in subjects with SCI were significantly greater (P <= 0.001) and more variable (P < 0.0001) than in AB subjects. Error scores were significantly correlated to clinical measure of joint position sense (r >= 0.507, P <= 0.013). Conclusions: This study shows that the Lokomat may be used as a reliable and valid clinical measurement tool for assessing joint position sense in persons with incomplete SCI. Quantitative assessments of proprioceptive deficits after neurological injury will help in understanding its role in the recovery of skilled walking and in the development of interventions to aid in the return to safe community ambulation.
引用
收藏
页数:10
相关论文
共 45 条
[1]  
Afifi AK., 2005, Functional Neuroanatomy: Text and Atlas, VSecond
[2]   Locomotor training in neurorehabilitation: Emerging rehabilitation concepts [J].
Barbeau, H .
NEUROREHABILITATION AND NEURAL REPAIR, 2003, 17 (01) :3-11
[3]   EFFECT OF ARTICULAR DISEASE AND TOTAL KNEE ARTHROPLASTY ON KNEE-JOINT POSITION SENSE [J].
BARRACK, RL ;
SKINNER, HB ;
COOK, SD ;
HADDAD, RJ .
JOURNAL OF NEUROPHYSIOLOGY, 1983, 50 (03) :684-687
[4]   Walking while resisting a perturbation: Effects on ankle dorsiflexor activation during swing and potential for rehabilitation [J].
Blanchette, Andreanne ;
Lambert, Sebastien ;
Richards, Carol L. ;
Bouyer, Laurent J. .
GAIT & POSTURE, 2011, 34 (03) :358-363
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   THE SENSATION OF PASSIVE MOVEMENT AT THE METATARSO-PHALANGEAL JOINT OF THE GREAT TOE IN MAN [J].
BROWNE, K ;
LEE, J ;
RING, PA .
JOURNAL OF PHYSIOLOGY-LONDON, 1954, 126 (03) :448-&
[7]   Proprioceptive acuity in the frontal and sagittal planes of the knee: a preliminary study [J].
Cammarata, Martha L. ;
Dhaher, Yasin Y. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (07) :1313-1320
[8]   Impaired limb position sense after stroke: A quantitative test for clinical use [J].
Carey, LM ;
Oke, LE ;
Matyas, TA .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (12) :1271-1278
[9]   ROLE OF INTRAMUSCULAR RECEPTORS IN THE AWARENESS OF LIMB POSITION [J].
CLARK, FJ ;
BURGESS, RC ;
CHAPIN, JW ;
LIPSCOMB, WT .
JOURNAL OF NEUROPHYSIOLOGY, 1985, 54 (06) :1529-1540
[10]   PROPRIOCEPTION IN THE CRUCIATE DEFICIENT KNEE [J].
CORRIGAN, JP ;
CASHMAN, WF ;
BRADY, MP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02) :247-250