摘要
An attempt has been made to develop a highly selective Cull-ion selective electrode based on a poly(vinyl chloride) based sensor using 1,2,5,6,8,11-hexaazacyclododeca-7,12-dione-2,4,8,10-tetraene as ionophore with 61.5% DBP in the presence of 29% PVC, 4.5% ionophore and 5% NaTBP as an anion excluder. The sensor exhibits a near Nernstian potential response of 29.5 +/- 0.3 mV per decade over a wide concentration range (2.0 x 10(-7) - 1 x 10(-1) M) with a detection limit of 8.1 x 10(-8) M between pH 3-11 with a fast response time of <5 s. The selectivity coefficient values, as determined by the matched potential method (MPM), indicate excellent selectivity for Cu(II) ions over a large number of ions. The proposed sensor exhibits an adequate shelf life (4 - 5 months) with good reproducibility. The quantification of Cu(II) in electroplating wastewater and various brands of Indian tea was successfully achieved using the proposed sensor.
引用
收藏
页码:683 / 687
页数:5
相关论文
共 43 条
[1]   Chemically modified carbon paste electrode for determination of copper(II) by potentiometric method [J].
Abbaspour, A ;
Moosavi, SMM .
TALANTA, 2002, 56 (01) :91-96
[2]   Copper(II)-selective electrode based on dithioacetal [J].
Abbaspour, A ;
Kamyabi, MA .
ANALYTICA CHIMICA ACTA, 2002, 455 (02) :225-231
[3]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[4]   BIS AND OLIGO(BENZOCROWN ETHER)S [J].
AN, HY ;
BRADSHAW, JS ;
IZATT, RM ;
YAN, ZM .
CHEMICAL REVIEWS, 1994, 94 (04) :939-991
[5]   COPPER-SENSITIVE MODIFIED POLY(PYRROLE) ELECTRODE [J].
ARCA, M ;
YILDIZ, A .
ELECTROANALYSIS, 1994, 6 (01) :79-82
[6]   Metalloporphyrin-based polymer membrane electrode with high selectivity for 2-hydroxybenzhydroxamate [J].
Badr, IHA ;
Meyerhoff, ME ;
Hassan, SSM .
ANALYTICA CHIMICA ACTA, 1996, 321 (01) :11-19
[7]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[8]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[9]  
Casabo J., 1994, J CHEM SOC DA, P1969
[10]   MACROCYCLIC POLYETHER TETRALACTAMS .4. POTENTIOMETRIC EVALUATION OF ION-SELECTIVE CHARACTERISTICS WITH ALKALINE-EARTH CATIONS [J].
CAZAUX, L ;
TISNES, P ;
PICARD, C ;
DSILVA, C ;
WILLIAMS, G .
ANALYST, 1994, 119 (11) :2315-2318