CLEAR-Scleral lenses

被引:54
作者
Barnett, Melissa [1 ]
Courey, Claudine [2 ]
Fadel, Daddi
Lee, Karen [3 ]
Michaud, Langis [2 ]
Montani, Giancarlo [4 ]
van der Worp, Eef [5 ]
Vincent, Stephen J. [6 ]
Walker, Maria [3 ]
Bilkhu, Paramdeep [7 ]
Morgan, Philip B. [8 ]
机构
[1] Univ Calif Davis, Eye Ctr, Sacramento, CA 95817 USA
[2] Univ Montreal, Ecole Optometrie, Montreal, PQ, Canada
[3] Univ Houston, Coll Optometry, Houston, TX USA
[4] Univ Salento, Dipartimento Matemat & Fis CERCA, Lecce, Italy
[5] Eye Contact Lens Res & Educ, Amsterdam, Netherlands
[6] Queensland Univ Technol QUT, Ctr Vis & Eye Res, Sch Optometry & Vis Sci, Contact Lens & Visual Opt Lab, Brisbane, Qld, Australia
[7] Aston Univ, Sch Optometry & Vis Sci, Birmingham, W Midlands, England
[8] Univ Manchester, Div Pharm & Optometry, Eurolens Res, Manchester, Lancs, England
关键词
Scleral lens; Keratoconus; Sagittal depth; Ocular surface disease; Ocular surface shape; Contact lens evidence-based academic reports (CLEAR);
D O I
10.1016/j.clae.2021.02.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Scleral lenses were the first type of contact lens, developed in the late nineteenth century to restore vision and protect the ocular surface. With the advent of rigid corneal lenses in the middle of the twentieth century and soft lenses in the 1970?s, the use of scleral lenses diminished; in recent times there has been a resurgence in their use driven by advances in manufacturing and ocular imaging technology. Scleral lenses are often the only viable form of contact lens wear across a range of clinical indications and can potentially delay the need for corneal surgery. This report provides a brief historical review of scleral lenses and a detailed account of contemporary scleral lens practice including common indications and recommended terminology. Recent research on ocular surface shape is presented, in addition to a comprehensive account of modern scleral lens fitting and on-eye evaluation. A range of optical and physiological challenges associated with scleral lenses are presented, including options for the clinical management of a range of ocular conditions. Future applications which take advantage of the stability of scleral lenses are also discussed. In summary, this report presents evidence-based recommendations to optimise patient outcomes in modern scleral lens practice.
引用
收藏
页码:270 / 288
页数:19
相关论文
共 333 条
[21]  
Barnett M, 2017, CONT SCLERAL LENSES, P423
[22]   Clinical Outcomes of Scleral Lens Fitting with a Data-driven, Quadrant-specific Design: Multicenter Review [J].
Barnett, Melissa ;
Carrasquillo, Karen G. ;
Schornack, Muriel M. .
OPTOMETRY AND VISION SCIENCE, 2020, 97 (09) :761-765
[23]   Anterior segment slitlamp photography using the iPhone [J].
Barsam, Alon ;
Bhogal, Maninder ;
Morris, Sharon ;
Little, Brian .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (07) :1240-1241
[24]   Prototype of a Smart Google Glass Solution for Deaf (and Hearing Impaired) People [J].
Berger, Ales ;
Maly, Filip .
MOBILE WEB AND INTELLIGENT INFORMATION SYSTEMS (MOBIWIS 2018), 2018, 10995 :38-47
[25]   Assessing Scleral Contact Lens Satisfaction in a Keratoconus Population [J].
Bergmanson, Jan P. G. ;
Walker, Maria K. ;
Johnson, Leah A. .
OPTOMETRY AND VISION SCIENCE, 2016, 93 (08) :855-860
[26]  
Bergmanson JP, 2017, CLIN EXP OPTOM, V100, P522, DOI DOI 10.1111/cxo.12583
[27]   HISTOPATHOLOGICAL ANALYSIS OF CORNEAL ENDOTHELIAL POLYMEGETHISM [J].
BERGMANSON, JPG .
CORNEA, 1992, 11 (02) :133-142
[28]  
BIER N, 1947, Am J Optom Arch Am Acad Optom, V24, P611
[29]  
Bier N, 1950, AM J OPTOM PHYS OPT, V27, P200
[30]  
Bier N, 1957, CONTACT LENS ROUTINE, V2nd