Left ventricular ejection fraction and volumes from gated blood-pool SPECT: Comparison with planar gated blood-pool imaging and assessment of repeatability in patients with heart failure

被引:0
|
作者
Wright, GA
Thackray, S
Howey, S
Cleland, JG
机构
[1] Hull Royal Infirm, Dept Nucl Med, Kingston Upon Hull, Yorks, England
[2] Univ Hull, Dept Cardiol, Castle Hill Hosp, Kingston Upon Hull, Yorks, England
关键词
blood-pool SPECT; ejection fraction; repeatability;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gated blood-pool SPECT (GBPS) has several potential advantages over planar radionuclide ventriculography (PRNV), including the possibility of greater repeatability of left ventricular ejection fraction (LVEF) and the noninvasive calculation of left ventricular end-systolic volume and left ventricular end-diastolic volume (LVEDV). The aim of this study was to assess the repeatability of LVEF and LVEDV from GBPS and to compare LVEF with those from PRNV. Methods: Fifty patients underwent PRNV and GBPS, 23 of whom also had repeated studies in the same session. GPBS studies were processed using the Cedars Sinai Quantitative Blood-Pool SPECT (QBS) software that automatically calculates LVEF and LVEDV. Automatic processing with QBS was successful in 70% of the GBPS studies, with the remaining studies processed using the manual option in QBS. All PRNV studies were processed using a manual processing technique. Results: Comparison of LVEF from PRNV and GBPS yielded a correlation coefficient of 0.80. Bland-Altman analysis demonstrated a mean difference of 0.74% +/- 7.62% (mean SD) between LVEF from the 2 techniques. The 95% limits of agreement are therefore -14.50% to +15.98%. The correlation between repeated measurements was 0.87 for GBPS and 0.95 for PRNV. Bland-Altman analysis revealed poorer repeatability for GBPS (95% limits of agreement, -9.63% to +14.97% vs. -4.66% to +5.92%; P = 0.003). The mean LVEDV was 198 94 mL, with a mean difference of 9 +/- 47 mL between repeated measurements. The 95% limits of agreement are therefore -85 to +103 mL. Conclusion: GBPS provides a less repeatable measurement of LVEF than PRNV. Repeatability of LVEDV measurements from GBPS is poor.
引用
收藏
页码:494 / 498
页数:5
相关论文
共 50 条
  • [1] Left ventricular ejection fraction: Comparison of results from planar and SPECT gated blood-pool studies
    Bartlett, ML
    Srinivasan, G
    Barker, WC
    Kitsiou, AN
    Dilsizian, V
    Bacharach, SL
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (11) : 1795 - 1799
  • [2] Automatic determination of left ventricular ejection fraction from gated blood-pool tomography
    Vanhove, C
    Franken, PR
    Defrise, M
    Momen, A
    Everaert, H
    Bossuyt, A
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (03) : 401 - 407
  • [3] Validation of Gated Blood-Pool SPECT Regional Left Ventricular Function Measurements
    Nichols, Kenneth J.
    Van Tosh, Andrew
    Wang, Yi
    Palestro, Christopher J.
    Reichek, Nathaniel
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (01) : 53 - 60
  • [4] Comparative values of gated blood-pool SPECT and CMR for ejection fraction and volume estimation
    Sibille, Louis
    Ben Bouallegue, Faycal
    Bourdon, Aurelie
    Micheau, Antoine
    Vernhet-Kovacsik, Helene
    Mariano-Goulart, Denis
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (02) : 121 - 128
  • [5] Gated blood-pool SPECT automated versus manual left ventricular function calculations
    Slart, RHJA
    Poot, L
    Piers, DA
    van Veldhuisen, DJ
    Nichols, K
    Jager, PL
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (01) : 75 - 80
  • [6] Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT
    Van Kriekinge, SD
    Berman, DS
    Germano, G
    JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (05) : 498 - 506
  • [7] Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT
    Serge D. Van Kriekinge
    Daniel S. Berman
    Guido Germano
    Journal of Nuclear Cardiology, 1999, 6 : 498 - 506
  • [8] Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT: Can we use the same reference database?
    Asit Kf. Paul
    Shinji Hasegawa
    Jun Yoshioka
    Hitoshi Yamaguchi
    Eiichiro Tsujimura
    Tsunehiko Nishimura
    Annals of Nuclear Medicine, 2000, 14 : 75 - 80
  • [9] Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT: Can we use the same reference database?
    Paul, AK
    Hasegawa, S
    Yoshioka, J
    Yamaguchi, H
    Tsujimura, E
    Nishimura, T
    ANNALS OF NUCLEAR MEDICINE, 2000, 14 (02) : 75 - 80
  • [10] Is TOMPOOL (gated blood-pool SPECT processing software) accurate to diagnose right and left ventricular dysfunction in a clinical setting?
    Dercle, Laurent
    Giraudmaillet, Thomas
    Pascal, Pierre
    Lairez, Olivier
    Chisin, Roland
    Marachet, Marie-Agnes
    Ouali, Monia
    Rousseau, Herve
    Bastie, Delphine
    Berry, Isabelle
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (05) : 1011 - 1022