Structure Modeling of the Glenoid: Relevance to Shoulder Arthroplasty

被引:10
作者
Sharma, Gulshan B. [1 ,2 ,3 ,4 ]
McMahon, Patrick J. [5 ]
Robertson, Douglas D. [1 ,2 ,3 ]
机构
[1] Emory Spine & Orthopaed Ctr, Atlanta, GA 30329 USA
[2] Georgia Inst Technol, Dept Biomed Engn, Atlanta, GA 30030 USA
[3] Emory Univ, Atlanta, GA 30030 USA
[4] Univ Calgary, Schulich Sch Engn, Dept Mech & Mfg Engn, Calgary, AB T2N 1N4, Canada
[5] Univ Pittsburgh, Dept Bioengn, Swanson Sch Engn, Pittsburgh, PA 15213 USA
关键词
glenoid; total shoulder arthroplasty; shape modeling; glenoid prosthesis; surgical instrumentation; COMPUTED-TOMOGRAPHY; COMPONENT; OSTEOARTHRITIS; REPLACEMENT; VERSION; SHAPE; RECONSTRUCTION; INSTABILITY; SURGERY; ANATOMY;
D O I
10.1002/jor.22696
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We applied shape modeling and principal component analysis (PCA) to discover glenoid bone structural relationships relevant to improving glenoid prosthesis features, fixation, and instrumentation. Knowledge of external bone morphology guides prosthesis shape and positioning, while internal bone morphology and bone density influence fixation. CT-based modeling defined nonarthritic glenoid subchondral bone surface and internal structure. First and second principal shape components were related to size and density. Reproducible structural parameters and glenoid feature relationships were discovered. Subchondral bone surface was approximated by a circle inferiorly and a triangle superiorly with the circle's center at a reproducible point along a superior-inferior line. Glenoid vault's maximum depth was at the circle's center, and the highest bone density was in posterior glenoid. Glenoid subchondral bone surface version varied from superior to inferior, but not by sex or side. Male subchondral bone surfaces were larger and more retroverted. Even if subchondral bone surfaces are deformed by arthritis, glenoid morphology can be identified by extra-articular landmarks, permitting location of the glenoid center and scapular orientation (glenoid version). Knowledge obtained from this study directs design of novel prosthesis features and instrumentation for use without pre-op CT or computer aided surgery. (c) 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:1471-1478, 2014.
引用
收藏
页码:1471 / 1478
页数:8
相关论文
共 50 条
  • [41] Total shoulder arthroplasty with an uncemented soft-metal-backed glenoid component
    Fucentese, Sandro F.
    Costouros, John G.
    Kuehnel, Stefanie-Peggy
    Gerber, Christian
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (04) : 624 - 631
  • [42] Glenoid bone grafting in primary reverse total shoulder arthroplasty
    Ernstbrunner, Lukas
    Werthel, Jean-David
    Wagner, Eric
    Hatta, Taku
    Sperling, John W.
    Cofield, Robert H.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (08) : 1441 - 1447
  • [43] Total shoulder arthroplasty does not correct the orientation of the eroded glenoid
    Gregory, Thomas
    Hansen, Ulrich
    Emery, Roger
    Amis, Andrew A.
    Mutchler, Celine
    Taillieu, Fabienne
    Augereau, Bernard
    ACTA ORTHOPAEDICA, 2012, 83 (05) : 529 - 535
  • [44] Glenoid morphology in reverse shoulder arthroplasty: Classification and surgical implications
    Frankle, Mark A.
    Teramoto, Atsushi
    Luo, Zong-Ping
    Levy, Jonathan C.
    Pupello, Derek
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (06) : 874 - 885
  • [45] Inconsistencies in measuring glenoid version in shoulder arthroplasty: a systematic review
    Varady, Nathan H.
    Bram, Joshua T.
    Chow, Jarred
    Taylor, Samuel A.
    Dines, Joshua S.
    Fu, Michael C.
    Ode, Gabriella E.
    Dines, David M.
    V. Gulotta, Lawrence
    Brusalis, Christopher M.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (02) : 639 - 649
  • [46] Pegged versus keeled glenoid components in total shoulder arthroplasty
    Throckmorton, Thomas W.
    Zarkadas, Peter C.
    Sperling, John W.
    Cofield, Robert H.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (05) : 726 - 733
  • [47] Stress analysis of cemented glenoid prostheses in Total Shoulder Arthroplasty
    Gupta, S
    van der Helm, FCT
    van Keulen, F
    JOURNAL OF BIOMECHANICS, 2004, 37 (11) : 1777 - 1786
  • [48] Management of Glenoid Bone Loss in Revision Total Shoulder Arthroplasty
    Scalise, Jason J.
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2008, 9 (02) : 85 - 90
  • [49] Radiographic results of augmented allpolyethylene glenoids in the presence of posterior glenoid bone loss during total shoulder arthroplasty
    Stephens, Scott P.
    Spencer, Edwin E.
    Wirth, Michael A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (05) : 798 - 803
  • [50] Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: A prospective-randomized clinical study
    Kircher, Joern
    Wiedemann, Markus
    Magosch, Petra
    Lichtenberg, Sven
    Habermeyer, Peter
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (04) : 515 - 520