Chest CT for the Diagnosis of Pediatric Esophageal Foreign Bodies

被引:7
作者
Sammer, Marla B. K. [1 ,2 ]
Kan, J. Herman [1 ,2 ]
Somcio, Ray [1 ,2 ]
Sher, Andrew C. [1 ,2 ]
Hansen, Carly M. [1 ]
Pahlka, R. Benton [1 ]
Guillerman, R. Paul [1 ,2 ]
Seghers, Victor J. [1 ,2 ]
机构
[1] Texas Childrens Hosp, Singleton Dept Pediat Radiol, 6701 Fannin St, Houston, TX 77030 USA
[2] Baylor Coll Med, Dept Radiol, Houston, TX 77030 USA
关键词
COMPUTED-TOMOGRAPHY; BODY INGESTION; MANAGEMENT; MDCT; ESOPHAGOGRAPHY; PERFORATION; CHILDREN; SHARP;
D O I
10.1067/j.cpradiol.2021.03.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Foreign body ingestion is a common problem in children. Radiography is the mainstay of imaging, but many radiolucent items go undetected without further imaging by fluoroscopic esophagram. While studies in adults support the use of computed tomography (CT) for esophageal foreign body ingestion, CT has historically not been used in children given the typically higher radiation doses on CT compared with fluoroscopy. In distinction to an esophagram, CT does not require oral contrast nor presence of an onsite radiologist and can be interpreted remotely. At our institution, a dedicated CT protocol has been used for airway foreign bodies since 2015. Given the advantages of CT over esophagram, we retrospectively reviewed institutional radiation dose data from 2017 to 2020 for esophagrams, airway foreign body CT (FB-CT), and routine CT Chest to compare effective doses for each modality. For ages 1+ years, effective dose was lowest using the FB-CT protocol; esophagram mean dose showed the most variability, and was over double the dose of FB-CT for ages 5+ years. Routine CT chest doses were uniformly highest across all age ranges. Given these findings, we instituted a CT foreign body imaging protocol as the first-line imaging modality for radiolucent esophageal foreign body at our institution. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:566 / 570
页数:5
相关论文
共 35 条
[1]   Protocol incorporating airway CT decreases negative bronchoscopy rates for suspected foreign bodies in pediatric patients [J].
Ahmed, Omar G. ;
Guillerman, Robert P. ;
Giannoni, Carla M. .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2018, 109 :133-137
[2]  
American College of Radiology, 2019, ACR ASER SCBT MR SPR
[3]  
[Anonymous], 2000, Report to the General Assembly, VII
[4]   Foreign-body ingestion in children: Experience with 1,265 cases [J].
Cheng, W ;
Tam, PKH .
JOURNAL OF PEDIATRIC SURGERY, 1999, 34 (10) :1472-1476
[5]   Technical innovation - Helical CT esophagography for the evaluation of suspected esophageal perforation or rupture [J].
Fadoo, F ;
Ruiz, DE ;
Dawn, SK ;
Webb, WR ;
Gotway, MB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (05) :1177-1179
[6]   A deadly examination [J].
Fruchter, O ;
Dragu, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (11) :1016-1016
[7]  
Fuentes Santos C, 2014, CASE REP PULMONOL, V2014, DOI DOI 10.1155/2014/215832
[8]   Computed Tomography for the Evaluation of Suspected Airway Foreign Bodies [J].
Giannoni, Carla M. ;
Guillerman, R. Paul .
CLINICAL PEDIATRIC EMERGENCY MEDICINE, 2015, 16 (04) :230-234
[9]   Diagnosis of foreign body aspiration with ultralow-dose CT using a tin filter: a comparison study [J].
Gordon, Lena ;
Nowik, Patrik ;
Mobini Kesheh, Shahla ;
Lidegran, Marika ;
Diaz, Sandra .
EMERGENCY RADIOLOGY, 2020, 27 (04) :399-404
[10]   Clinical Guidelines for Imaging and Reporting Ingested Foreign Bodies [J].
Guelfguat, Mark ;
Kaplinskiy, Vladimir ;
Reddy, Srinivas H. ;
DiPoce, Jason .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (01) :37-53