Quiescent-Interval Single-Shot Unenhanced Magnetic Resonance Angiography of Peripheral Vascular Disease: Technical Considerations and Clinical Feasibility

被引:143
作者
Edelman, Robert R. [1 ]
Sheehan, John J. [1 ]
Dunkle, Eugene [1 ]
Schindler, Nancy [2 ]
Carr, James [3 ]
Koktzoglou, Ioannis [1 ]
机构
[1] NorthShore Univ HealthSyst, Dept Radiol, Evanston, IL 60201 USA
[2] NorthShore Univ HealthSyst, Dept Surg, Evanston, IL 60201 USA
[3] Northwestern Univ, NW Radiol & Feinberg Sch Med, Chicago, IL 60611 USA
关键词
magnetic resonance angiography unenhanced; flow; peripheral vascular disease; steady-state precession; two dimensional; FLIGHT MR-ANGIOGRAPHY; LOWER-EXTREMITIES; ARTERIAL-DISEASE; OCCLUSIVE DISEASE;
D O I
10.1002/mrm.22287
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We performed technical optimization followed by a pilot clinical study of quiescent-interval single-shot MR angiography for peripheral vascular disease. Quiescent-interval single-shot MR angiography acquires data using a modified electrocardiographic (ECG)-triggered, fat suppressed, two-dimensional, balanced steady-state, free precession pulse sequence incorporating slice-selective saturation and a quiescent interval for maximal enhancement of inflowing blood. Following optimization at 1.5 T, a pilot study was performed in patients with peripheral vascular disease, using contrast-enhanced MR angiography as the reference standard. The optimized sequence used a quiescent interval of 228 ms, alpha/2 catalyzation of the steady-state magnetization, and center-to-out partial Fourier acquisition with parallel acceleration factor of 2. Spatial resolution was 2-3mm along the slice direction and 0.7-1mm in-plane before interpolation. Excluding stented arterial segments, the sensitivity, specificity, and positive and negative predictive values of quiescent-interval single-shot MR angiography for arterial narrowing greater than 50% or occlusion were 92.2%, 94.9%, 83.9%, and 97.7%, respectively. Quiescent-interval single-shot MR angiography provided robust depiction of normal peripheral arterial anatomy and peripheral vascular disease in less than 10 min, without the need to tailor the technique for individual patients. Moreover, the technique provides consistent image quality in the pelvic region despite the presence of respiratory and bowel motion. Magn Reson Med 63:951-958, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:951 / 958
页数:8
相关论文
共 17 条
[1]   THE PREVALENCE OF PERIPHERAL ARTERIAL-DISEASE IN A DEFINED POPULATION [J].
CRIQUI, MH ;
FRONEK, A ;
BARRETTCONNOR, E ;
KLAUBER, MR ;
GABRIEL, S ;
GOODMAN, D .
CIRCULATION, 1985, 71 (03) :510-515
[2]  
Deimling M., 1994, PROC 2 ANN M SMR SAN, P495
[3]   Unenhanced Flow-Independent MR Venography by Using Signal Targeting Alternative Radiofrequency and Flow-Independent Relaxation Enhancement [J].
Edelman, Robert R. ;
Koktzoglou, Ioannis .
RADIOLOGY, 2009, 250 (01) :236-245
[4]   MR angiography of the lower extremities [J].
Ersoy, Hale ;
Rybicki, Frank J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (06) :1675-1684
[5]   TrueFISP - technical considerations and cardiovascular applications [J].
Fuchs, F ;
Laub, G ;
Othomo, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 46 (01) :28-32
[6]   Peripheral arterial disease in patients with stages IV and V chronic renal failure [J].
Guerrero, Angeles ;
Montes, Rafael ;
Munoz-Terol, Jose ;
Gil-Peralta, Alberto ;
Toro, Javier ;
Naranjo, Macarena ;
Gonzalez-Perez, Paloma ;
Martin-Herrera, Carmen ;
Ruiz-Fernandez, Ana .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (12) :3525-3531
[7]   Drug therapy - Medical treatment of peripheral arterial disease and claudication. [J].
Hiatt, WR .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (21) :1608-1621
[8]   Two-dimensional time-of-flight MR angiography of the lower extremities: Artifacts and pitfalls [J].
Kaufman, JA ;
McCarter, D ;
Geller, SC ;
Waltman, AC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) :129-135
[9]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[10]   Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis [J].
Kuo, Phillip H. ;
Kanal, Emanuel ;
Abu-Alfa, Ali K. ;
Cowper, Shawn E. .
RADIOLOGY, 2007, 242 (03) :647-649