Detection of small bleeds in the brain with electrical impedance tomography

被引:27
|
作者
Boverman, Gregory [1 ]
Kao, Tzu-Jen [1 ]
Wang, Xin [1 ]
Ashe, Jeffrey M. [1 ]
Davenport, David M. [1 ]
Amm, Bruce C. [1 ]
机构
[1] GE Global Res Ctr, 1 Res Circle, Niskayuna, NY 12309 USA
关键词
electrical impedance tomography; contact impedance; hemorrhagic stroke; complete electrode model; statistical detection theory; CURRENT COMPUTED-TOMOGRAPHY; DIELECTRIC-PROPERTIES; BIOLOGICAL TISSUES; ELECTRODE MODELS; BREAST; EIT;
D O I
10.1088/0967-3334/37/6/727
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper, we describe and assess feasibility of instrumentation and algorithms for detecting bleeding due to hemorrhagic strokes and traumatic brain injury using electrical impedance tomography, a novel biomedical diagnostic modality in which the body is probed noninvasively with generally imperceptible alternating currents applied in patterns to a set of electrodes placed in contact with the skin. We focus on the GENESIS instrument developed by GE Global Research and on the achievability of our goal to detect a bleed in the center of the head with a volume of several ml. Our main topic is compensation for the large changes in voltages that tend to occur when the electrodes are in contact with biological media, specifically either human subjects or with vegetable matter proxies which seem to exhibit the same 'drift' phenomenon. We show that these changes in voltages can be modeled by assuming that each electrode is attached to the body via a discrete complex impedance whose value is time-varying and describe how this discrete component value can be estimated and largely compensated-for. We compare this discrete model with changes in contact impedances estimated using the complete electrode model showing that the two models are roughly comparable in their ability to explain the data from a single human subject experiment with electrodes attached to the head. In a simulation study, we demonstrate that it is possible to detect a small bleed in the center of the head even in the case of large changes in electrode impedances, which can be treated as nuisance parameters.
引用
收藏
页码:727 / 750
页数:24
相关论文
共 50 条
  • [1] Electrical Impedance Tomography of brain function
    Holder, David S.
    2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1783 - 1788
  • [2] Krylov subspace iterative techniques: On the detection of brain activity with electrical impedance tomography
    Polydorides, N
    Lionheart, WRB
    McCann, H
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (06) : 596 - 603
  • [3] Imaging fast electrical activity in the brain with electrical impedance tomography
    Aristovich, Kirill Y.
    Packham, Brett C.
    Koo, Hwan
    dos Santos, Gustavo Sato
    McEvoy, Andy
    Holder, David S.
    NEUROIMAGE, 2016, 124 : 204 - 213
  • [4] Brain haemorrhage detection using a SVM classifier with electrical impedance tomography measurement frames
    McDermott, Barry
    O'Halloran, Martin
    Porter, Emily
    Santorelli, Adam
    PLOS ONE, 2018, 13 (07):
  • [5] Experimental Study of Detection of Brain Tissue with Electrical Impedance Tomography after Cerebral Ischemic
    CHEN Chao-shuang
    FU Feng
    LI Bing
    LIU Wen-bo
    XU Shi-wei
    TAO Feng
    SHI Xue-tao
    YANG Lin
    FEI Zhou
    DONG Xiu-zhen
    ChineseJournalofBiomedicalEngineering, 2017, 26 (02) : 75 - 81
  • [6] Study on human brain impedance imaging using electrical impedance tomography
    Xu, GZ
    Dong, GY
    Yan, WL
    Yang, QX
    PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC FIELD PROBLEMS AND APPLICATIONS, 2000, : 378 - 380
  • [7] Reconstruction of Small Inclusions in Electrical Impedance Tomography Problems
    Fang, Xiaoping
    Deng, Youjun
    Chen, Xiaohong
    EAST ASIAN JOURNAL ON APPLIED MATHEMATICS, 2019, 9 (02) : 280 - 294
  • [8] Capacitively Coupled Electrical Impedance Tomography for Brain Imaging
    Jiang, Y. D.
    Soleimani, M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (09) : 2104 - 2113
  • [9] DETECTION OF GASTROESOPHAGEAL REFLUX BY ELECTRICAL-IMPEDANCE TOMOGRAPHY
    RAVELLI, AM
    MILLA, PJ
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1994, 18 (02): : 205 - 213
  • [10] Optimized breath detection algorithm in electrical impedance tomography
    Khodadad, D.
    Nordebo, S.
    Muller, B.
    Waldmann, A.
    Yerworth, R.
    Becher, T.
    Frerichs, I
    Sophodeous, L.
    Van Kaam, A.
    Miedema, M.
    Seifnaraghi, N.
    Bayford, R.