Corneal changes after laser refractive surgery for myopia: Comparison of Orbscan II and Pentacam findings

被引:75
作者
Hashemi, Hassan
Mehravaran, Shiva
机构
[1] Noor Vis Correct Ctr, Tehran 1968655751, Iran
[2] Univ Tehran Med Sci, Farabi Eye Hosp, Dept Ophthalmol, Sch Med, Tehran, Iran
关键词
D O I
10.1016/j.jcrs.2007.01.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the agreement between scanning slit topography (Orbscan II, Bausch & Lomb) and Scheimpflug imaging (Pentacam, Oculus) in corneal elevation, corneal curvature, and anterior chamber depth (ACD) measurements before and after laser refractive surgery for myopia and to compare the postoperative changes seen with these devices. SETTING: Noor Vision Correction Center, Tehran, Iran. METHODS: In a prospective observational case-series study, 23 consecutive myopic patients having laser refractive surgery were examined with the Orbscan II and Pentacam preoperatively and 6 weeks postoperatively. Readings of ACD, anterior (A-) and posterior (P-) best-fit sphere (BFS) size, central elevation (CE), maximum elevation (ME), axial power in the 3.0 mm zone (AX3) and 5.0 mm zone (AX5), and tangential power in these zones (TG3 and TG5, respectively) were collected and used in the analyses. RESULTS: Statistically significant interdevice differences were found preoperatively for all parameters except P-TG3 (P = .014) and in operated eyes for ACD, anterior parameters of A-AX3 and A-AX5, and all posterior corneal parameters. In posterior corneal measurements, Orbscan II demonstrated significant postoperative changes in all parameters except P-AX5 (P = .004) and P-TG5 (P = .034), although none of the differences was statistically significant with the Pentacam. The devices measured similar postoperative changes in anterior curvature parameters and in P-AX5 and P-TG5; all other changes were significantly different. CONCLUSIONS: Compared to the Pentacam, the Orbscan II yielded larger posterior elevation values before and after surgery and significant postoperative changes in P-CE and P-ME. Further studies can determine which device gives more accurate images of the cornea and redefine screening criteria.
引用
收藏
页码:841 / 847
页数:7
相关论文
共 20 条
[11]   Residual bed thickness and corneal forward shift after laser in situ keratomileusis [J].
Miyata, K ;
Tokunaga, T ;
Nakahara, M ;
Ohtani, S ;
Nejima, R ;
Kiuchi, T ;
Kaji, Y ;
Oshika, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (05) :1067-1072
[12]   Evaluation of apparent ectasia of the posterior surface of the cornea after keratorefractive surgery [J].
Nawa, Y ;
Masuda, K ;
Ueda, T ;
Hara, Y ;
Uozato, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (03) :571-573
[13]   Changes in the posterior corneal surface after LASIK [J].
Ormonde, S ;
Waterman, C ;
McGhee, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03) :533-534
[14]   Posterior corneal curvature changes after myopic laser in situ keratomileusis [J].
Seitz, B ;
Torres, F ;
Langenbucher, A ;
Behrens, A ;
Suárez, E .
OPHTHALMOLOGY, 2001, 108 (04) :666-672
[15]   Posterior corneal topographic changes after partial flap during laser in situ keratomileusis [J].
Sharma, N ;
Rani, A ;
Balasubramanya, R ;
Vajpayee, RB ;
Pandey, RM .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (02) :160-162
[16]  
SWARTZ T, 2006, CORNEAL TOPOGRAPHY W, P31
[17]   Response of the posterior in situ keratomileusis for corneal surface to laser myopia [J].
Twa, MD ;
Roberts, C ;
Mahmoud, AM ;
Chang, JS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :61-71
[18]   Posterior corneal surface changes after hyperopic laser in situ keratomileusis [J].
Ueda, T ;
Nawa, Y ;
Masuda, K ;
Ishibashi, H ;
Hara, Y ;
Uozato, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (11) :2084-2087
[19]   Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thickness [J].
Wang, Z ;
Chen, JQ ;
Yang, B .
OPHTHALMOLOGY, 1999, 106 (02) :406-409
[20]   Difference map or single elevation map in the evaluation of corneal forward shift after LASIK [J].
Yoshida, T ;
Miyata, K ;
Tokunaga, T ;
Tanabe, T ;
Oshika, T .
OPHTHALMOLOGY, 2003, 110 (10) :1926-1930