Corneal changes after laser refractive surgery for myopia: Comparison of Orbscan II and Pentacam findings

被引:75
作者
Hashemi, Hassan
Mehravaran, Shiva
机构
[1] Noor Vis Correct Ctr, Tehran 1968655751, Iran
[2] Univ Tehran Med Sci, Farabi Eye Hosp, Dept Ophthalmol, Sch Med, Tehran, Iran
关键词
D O I
10.1016/j.jcrs.2007.01.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the agreement between scanning slit topography (Orbscan II, Bausch & Lomb) and Scheimpflug imaging (Pentacam, Oculus) in corneal elevation, corneal curvature, and anterior chamber depth (ACD) measurements before and after laser refractive surgery for myopia and to compare the postoperative changes seen with these devices. SETTING: Noor Vision Correction Center, Tehran, Iran. METHODS: In a prospective observational case-series study, 23 consecutive myopic patients having laser refractive surgery were examined with the Orbscan II and Pentacam preoperatively and 6 weeks postoperatively. Readings of ACD, anterior (A-) and posterior (P-) best-fit sphere (BFS) size, central elevation (CE), maximum elevation (ME), axial power in the 3.0 mm zone (AX3) and 5.0 mm zone (AX5), and tangential power in these zones (TG3 and TG5, respectively) were collected and used in the analyses. RESULTS: Statistically significant interdevice differences were found preoperatively for all parameters except P-TG3 (P = .014) and in operated eyes for ACD, anterior parameters of A-AX3 and A-AX5, and all posterior corneal parameters. In posterior corneal measurements, Orbscan II demonstrated significant postoperative changes in all parameters except P-AX5 (P = .004) and P-TG5 (P = .034), although none of the differences was statistically significant with the Pentacam. The devices measured similar postoperative changes in anterior curvature parameters and in P-AX5 and P-TG5; all other changes were significantly different. CONCLUSIONS: Compared to the Pentacam, the Orbscan II yielded larger posterior elevation values before and after surgery and significant postoperative changes in P-CE and P-ME. Further studies can determine which device gives more accurate images of the cornea and redefine screening criteria.
引用
收藏
页码:841 / 847
页数:7
相关论文
共 20 条
[1]   Factors affecting the forward shift of posterior corneal surface after laser in situ keratomileusis [J].
Baek, TM ;
Lee, KH ;
Kagaya, F ;
Tomidokoro, A ;
Amano, S ;
Oshika, T .
OPHTHALMOLOGY, 2001, 108 (02) :317-320
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures [J].
Cairns, G ;
Ormonde, SE ;
Gray, T ;
Hadden, OB ;
Morris, T ;
Ring, P ;
McGhee, CNJ .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (02) :147-152
[4]   Accuracy of Orbscan II slit-scanning elevation topography [J].
Cairns, G ;
McGhee, CNJ ;
Collins, MJ ;
Owens, H ;
Gamble, GD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12) :2181-2187
[5]   Changes in the posterior cornea after laser in situ keratomileusis and photorefractive keratectomy [J].
Ciolino, Joseph B. ;
Belin, Michael W. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09) :1426-1431
[6]   Model for nonectatic increase in posterior corneal elevation after ablative procedures [J].
Grzybowski, DM ;
Roberts, CJ ;
Mahmoud, AM ;
Chang, JS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :72-81
[7]  
Guirao A, 2005, J REFRACT SURG, V21, P176
[8]   Posterior corneal surface changes after refractive surgery [J].
Hernández-Quintela, E ;
Samapunphong, S ;
Khan, BF ;
Gonzalez, B ;
Lu, PCS ;
Farah, SG ;
Azar, DT .
OPHTHALMOLOGY, 2001, 108 (08) :1415-1422
[9]   Influence of excimer laser photorefractive keratectomy on the posterior corneal surface [J].
Kamiya, K ;
Oshika, T ;
Amano, S ;
Takahashi, T ;
Tokunaga, T ;
Miyata, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (06) :867-871
[10]   Early spatial changes in the posterior corneal surface after laser in situ keratomileusis [J].
Lee, DH ;
Seo, S ;
Jeong, KW ;
Shin, SC ;
Vukich, JA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04) :778-784