共 10 条
Generic real-time uniform K-space sampling method for high-speed swept-Source optical coherence tomography
被引:72
作者:
Xi, Jiefeng
[1
]
Huo, Li
[1
]
Li, Jiasong
[1
]
Li, Xingde
[1
]
机构:
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
基金:
美国国家卫生研究院;
美国国家科学基金会;
关键词:
DOMAIN;
LASER;
D O I:
10.1364/OE.18.009511
中图分类号:
O43 [光学];
学科分类号:
070207 ;
0803 ;
摘要:
We developed a universal, real-time uniform K-space sampling (Rt-UKSS) method for high-speed swept-source optical coherence tomography (SS-OCT). An external clock uniform in K-space was generated. The clock was synchronized with the zero-crossing time of an interferometric calibration signal and used as triggers for a high-speed data acquisition system in a point-by-point fashion, hence enabling uniform data sampling in K-space. Different from the numerical calibration algorithm commonly used in an SS-OCT system, the method reported here does not require over-sampling, thus greatly reducing the demand for digitization, data processing and storage speed. The Rt-UKSS method is adaptive and applicable to a generic SS-OCT system of a wide range of A-scan rates without special adjustment. We successfully implemented the Rt-UKSS method in an SS-OCT system based on a Fourier-domain mode-locked laser (FDML) of a 40-kHz scanning rate. Real-time imaging of biological tissues using such a system was demonstrated with a measured axial resolution of 9.3 mu m and detection sensitivity greater than 120dB. (C) 2010 Optical Society of America
引用
收藏
页码:9511 / 9517
页数:7
相关论文