Novel field amplification for sensitive colorimetric detection of microalbuminuria on a paper-based analytical device

被引:31
作者
Cai, Yu [1 ]
Niu, Ji-Cheng [1 ]
Du, Xin-Li [2 ]
Fang, Fang [1 ]
Wu, Zhi-Yong [1 ]
机构
[1] Northeastern Univ, Coll Sci, Res Ctr Analyt Sci, Chem Dept, Shenyang 110819, Liaoning, Peoples R China
[2] Liaoning Diabet Treatment Ctr, Shenyang 110015, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
Paper-based analytical device; Geometric field amplification; Microalbuminuria; Colorimetric detection; Smart phone camera; ELECTROKINETIC STACKING; SAMPLE STACKING; URINARY ALBUMIN; PERFORMANCE; PROTEINS; PROTEOME; POINT;
D O I
10.1016/j.aca.2019.06.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Field-amplified stacking (FAS) is a commonly used method for enhancing the sensitivity of charged species from low conductive media in capillary electrophoresis. FAS also showed significant sensitivity enhancement effect on a uniform paper fluidic channel by proper design of the electrolyte. In this paper, a novel method of introducing electric field gradient is proposed by geometry design of a 2D paper fluidic channel, and field amplification effect was successfully demonstrated with reduced requirement on the sample's conductivity. Sensitive colorimetric detection of microalbuminuria (MAU) from urine samples was demonstrated by mobile phone camera. Experimental results showed that, with active electric field motivation, up to 93.5% of the loaded protein probe could be effectively transferred and stacked into a narrow band on the newly designed paper fluidic channel. A limit of detection (LOD) of 6.5 mg.L-1 HSA was achieved with a dynamic range of 10-300 mg.L-1 (linear in the range of 10-100 mg.L-1, R-2 = 0.991). Combined with selective staining of albumin with bromophenol blue (BPB), the established method was applied to the detection of MAU from clinical urine samples, and consistent results with that of the clinical method were obtained. With this paper-based analytical device (PAD), MAU from highly conductive urine samples can be directly loaded and detected without any pretreatment. This method provides a way to develop highly sensitive point-of-care test (POCT) for rapid screening of some diseases. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:146 / 152
页数:7
相关论文
共 31 条
[1]   The human plasma proteome - History, character, and diagnostic prospects [J].
Anderson, NL ;
Anderson, NG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (11) :845-867
[2]   Paper-Based Systems for Point-of-Care Biosensing [J].
Cheung, Sherine F. ;
Cheng, Samantha K. L. ;
Kamei, Daniel T. .
JALA, 2015, 20 (04) :316-333
[3]   Differences in urinary albumin detected by four immunoassays and high-performance liquid chromatography [J].
Comper, WD ;
Jerums, G ;
Osicka, TM .
CLINICAL BIOCHEMISTRY, 2004, 37 (02) :105-111
[4]  
Gao H, 2018, ANALOG CIRC SIG PROC, P21, DOI 10.1007/978-3-319-72980-0_4
[5]   A tunable isoelectric focusing via moving reaction boundary for two-dimensional gel electrophoresis and proteomics [J].
Guo, Chen-Gang ;
Shang, Zhi ;
Yan, Jian ;
Li, Si ;
Li, Guo-Qing ;
Liu, Rong-Zhong ;
Qing, Ying ;
Fan, Liu-Yin ;
Xiao, Hua ;
Cao, Cheng-Xi .
TALANTA, 2015, 137 :197-203
[6]   Low-molecular-weight human serum proteome using ultrafiltration, isoelectric focusing, and mass spectrometry [J].
Harper, RG ;
Workman, SR ;
Schuetzner, S ;
Timperman, AT ;
Sutton, JN .
ELECTROPHORESIS, 2004, 25 (09) :1299-1306
[7]   Determination of five macrolide antibiotic residues in milk by micellar electrokinetic capillary chromatography with field amplified sample stacking [J].
Hong, Yue-Qin ;
Guo, Xin ;
Chen, Guan-Hua ;
Zhou, Jia-Wei ;
Zou, Xue-Mei ;
Liao, Xue ;
Hou, Ting .
JOURNAL OF FOOD SAFETY, 2018, 38 (01)
[8]   Combination of large-volume sample stacking with an electroosmotic flow pump with field-amplified sample injection on cross-channel chips [J].
Kitagawa, Fumihiko ;
Ishiguro, Tatsuya ;
Tateyama, Misaki ;
Nukatsuka, Isoshi ;
Sueyoshi, Kenji ;
Kawai, Takayuki ;
Otsuka, Koji .
ELECTROPHORESIS, 2017, 38 (16) :2075-2080
[9]   Gold nanoparticle-based colorimetric methods to determine protein contents in artificial urine using membrane micro-concentrators and mobile phone camera [J].
Lai, Teh-Sheng ;
Chang, Ting-Chou ;
Wang, Shau-Chun .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 :9-16
[10]   Low-voltage paper isotachophoresis device for DNA focusing [J].
Li, Xiang ;
Luo, Long ;
Crooks, Richard M. .
LAB ON A CHIP, 2015, 15 (20) :4090-4098