Long-term real-life glycaemic outcomes with a hybrid closed-loop system compared with sensor-augmented pump therapy in patients with type 1 diabetes

被引:71
作者
Akturk, Halis Kaan [1 ]
Giordano, Dominique [1 ]
Champakanath, Anagha [1 ]
Brackett, Scott [1 ]
Garg, Satish [1 ]
Snell-Bergeon, Janet [1 ]
机构
[1] Univ Colorado, Barbara Davis Ctr Diabet, Aurora, CO USA
关键词
continuous glucose monitoring; CSII; glycaemic control; insulin pump therapy; type; 1; diabetes; INSULIN-DELIVERY-SYSTEM; ADOLESCENTS; CHILDREN; SAFETY; ADULTS;
D O I
10.1111/dom.13933
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim To compare glycaemic metrics at 3 and 6 months in patients with type 1 diabetes on a 670G hybrid closed-loop (HCL) system after using a sensor-augmented pump (SAP) for at least 3 months. Materials and Methods A retrospective study from a centre that has the largest number of 670G users in the United States was conducted. Data from 202 SAP users were reviewed. Sixty-one patients were excluded (two for steroid use, four for pregnancy, 27 for previous Enlite use, and 28 for non-continuous use of 670G). Out of 141 patients who met the inclusion criteria, 127 (aged 21-68 years) had complete data. Results HbA1c levels decreased by 0.4% at 3 months and were maintained at 6 months (7.6 +/- 0.07 vs. 7.2 +/- 0.08, P < 0.001) with no weight gain at 6 months. Time-in-range (70-180 mg/dL) increased from 59.5% +/- 1.1% to 70.2% +/- 1.2% and 70.1% +/- 1.1% at 3 and 6 months (P < 0.001), respectively. At 6 months, time spent in hypoglycaemia (<70 mg/dL) and time spent in hyperglycaemia (>180 mg/dL) were reduced by 30% (2.2% +/- 0.2% vs. 3.2% +/- 0.2%; P < 0.05) and 26% (28.3% +/- 1.2% vs. 38.1% +/- 1.2%; P < 0.001), respectively. More time in auto-mode was associated with improved continuous glucose monitoring metrics, lower HbA1c and decreased glycaemic variability. Time in auto-mode declined in men after 3 months, while women maintained similar auto-mode use throughout the study. Conclusions The HCL system improved HbA1c levels and time-in-range, and decreased time spent in hypoglycaemia and hyperglycaemia at 6 months. Auto-mode use was significantly correlated with continuous glucose monitoring metrics and glycaemic outcomes.
引用
收藏
页码:583 / 589
页数:7
相关论文
共 22 条
[1]   Technological advances shaping diabetes care [J].
Akturk, Halis Kaan ;
Garg, Satish .
CURRENT OPINION IN ENDOCRINOLOGY DIABETES AND OBESITY, 2019, 26 (02) :84-89
[2]   INTEGRATED INSULIN PUMP AND CONTINUOUS GLUCOSE MONITORING TECHNOLOGY IN DIABETES CARE TODAY: A PERSPECTIVE OF REAL-LIFE EXPERIENCE WITH THE MINIMED™ 670G HYBRID CLOSED-LOOP SYSTEM [J].
Aleppo, Grazia ;
Webb, Kimberly M. .
ENDOCRINE PRACTICE, 2018, 24 (07) :684-692
[3]   Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range [J].
Battelino, Tadej ;
Danne, Thomas ;
Bergenstal, Richard M. ;
Amiel, Stephanie A. ;
Beck, Roy ;
Biester, Torben ;
Bosi, Emanuele ;
Buckingham, Bruce A. ;
Cefalu, William T. ;
Close, Kelly L. ;
Cobelli, Claudio ;
Dassau, Eyal ;
DeVries, J. Hans ;
Donaghue, Kim C. ;
Dovc, Klemen ;
Doyle, Francis J. ;
Garg, Satish ;
Grunberger, George ;
Heller, Simon ;
Heinemann, Lutz ;
Hirsch, Irl B. ;
Hovorka, Roman ;
Jia, Weiping ;
Kordonouri, Olga ;
Kovatchev, Boris ;
Kowalski, Aaron ;
Laffel, Lori ;
Levine, Brian ;
Mayorov, Alexander ;
Mathieu, Chantal ;
Murphy, Helen R. ;
Nimri, Revital ;
Norgaard, Kirsten ;
Parkin, Christopher G. ;
Renard, Eric ;
Rodbard, David ;
Saboo, Banshi ;
Schatz, Desmond ;
Stoner, Keaton ;
Urakami, Tatsuiko ;
Weinzimer, Stuart A. ;
Phillip, Moshe .
DIABETES CARE, 2019, 42 (08) :1593-1603
[4]   Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes [J].
Bergenstal, Richard M. ;
Garg, Satish ;
Weinzimer, Stuart A. ;
Buckingham, Bruce A. ;
Bode, Bruce W. ;
Tamborlane, William V. ;
Kaufman, Francine R. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (13) :1407-1408
[5]   International Consensus on Use of Continuous Glucose Monitoring [J].
Danne, Thomas ;
Nimri, Revital ;
Battelino, Tadej ;
Bergenstal, Richard M. ;
Close, Kelly L. ;
DeVries, J. Hans ;
Garg, Satish ;
Heinemann, Lutz ;
Hirsch, Irl ;
Amiel, Stephanie A. ;
Beck, Roy ;
Bosi, Emanuele ;
Buckingham, Bruce ;
Cobelli, Claudio ;
Dassau, Eyal ;
Doyle, Francis J., III ;
Heller, Simon ;
Hovorka, Roman ;
Jia, Weiping ;
Jones, Tim ;
Kordonouri, Olga ;
Kovatchev, Boris ;
Kowalski, Aaron ;
Laffel, Lori ;
Maahs, David ;
Murphy, Helen R. ;
Norgaard, Kirsten ;
Parkin, Christopher G. ;
Renard, Eric ;
Saboo, Banshi ;
Scharf, Mauro ;
Tamborlane, William V. ;
Weinzimer, Stuart A. ;
Phillip, Moshe .
DIABETES CARE, 2017, 40 (12) :1631-1640
[6]   REAL-WORLD IMPLICATIONS OF HYBRID CLOSE LOOP (HCL) INSULIN DELIVERY SYSTEM [J].
Faulds, Eileen R. ;
Zappe, Janet ;
Dungan, Kathleen M. .
ENDOCRINE PRACTICE, 2019, 25 (05) :477-484
[7]   Safety Evaluation of the MiniMed 670G System in Children 7-13 Years of Age with Type 1 Diabetes [J].
Forlenza, Gregory P. ;
Pinhas-Hamiel, Orit ;
Liljenquist, David R. ;
Shulman, Dorothy I. ;
Bailey, Timothy S. ;
Bode, Bruce W. ;
Wood, Michael A. ;
Buckingham, Bruce A. ;
Kaiserman, Kevin B. ;
Shin, John ;
Huang, Suiying ;
Lee, Scott W. ;
Kaufman, Francine R. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (01) :11-19
[8]   State of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016-2018 [J].
Foster, Nicole C. ;
Beck, Roy W. ;
Miller, Kellee M. ;
Clements, Mark A. ;
Rickels, Michael R. ;
DiMeglio, Linda A. ;
Maahs, David M. ;
Tamborlane, William V. ;
Bergenstal, Richard ;
Smith, Elizabeth ;
Olson, Beth A. ;
Garg, Satish K. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (02) :66-72
[9]   Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 Diabetes [J].
Garg, Satish K. ;
Weinzimer, Stuart A. ;
Tamborlane, William V. ;
Buckingham, Bruce A. ;
Bode, Bruce W. ;
Bailey, Timothy S. ;
Brazg, Ronald L. ;
Ilany, Jacob ;
Slover, Robert H. ;
Anderson, Stacey M. ;
Bergenstal, Richard M. ;
Grosman, Benyamin ;
Roy, Anirban ;
Cordero, Toni L. ;
Shin, John ;
Lee, Scott W. ;
Kaufman, Francine R. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (03) :155-163
[10]   One Year Clinical Experience of the First Commercial Hybrid Closed-Loop System [J].
Lal, Rayhan A. ;
Basina, Marina ;
Maahs, David M. ;
Hood, Korey ;
Buckingham, Bruce ;
Wilson, Darrell M. .
DIABETES CARE, 2019, 42 (12) :2190-2196