Long-term real-life glycaemic outcomes with a hybrid closed-loop system compared with sensor-augmented pump therapy in patients with type 1 diabetes

被引:66
作者
Akturk, Halis Kaan [1 ]
Giordano, Dominique [1 ]
Champakanath, Anagha [1 ]
Brackett, Scott [1 ]
Garg, Satish [1 ]
Snell-Bergeon, Janet [1 ]
机构
[1] Univ Colorado, Barbara Davis Ctr Diabet, Aurora, CO USA
关键词
continuous glucose monitoring; CSII; glycaemic control; insulin pump therapy; type; 1; diabetes; INSULIN-DELIVERY-SYSTEM; ADOLESCENTS; CHILDREN; SAFETY; ADULTS;
D O I
10.1111/dom.13933
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim To compare glycaemic metrics at 3 and 6 months in patients with type 1 diabetes on a 670G hybrid closed-loop (HCL) system after using a sensor-augmented pump (SAP) for at least 3 months. Materials and Methods A retrospective study from a centre that has the largest number of 670G users in the United States was conducted. Data from 202 SAP users were reviewed. Sixty-one patients were excluded (two for steroid use, four for pregnancy, 27 for previous Enlite use, and 28 for non-continuous use of 670G). Out of 141 patients who met the inclusion criteria, 127 (aged 21-68 years) had complete data. Results HbA1c levels decreased by 0.4% at 3 months and were maintained at 6 months (7.6 +/- 0.07 vs. 7.2 +/- 0.08, P < 0.001) with no weight gain at 6 months. Time-in-range (70-180 mg/dL) increased from 59.5% +/- 1.1% to 70.2% +/- 1.2% and 70.1% +/- 1.1% at 3 and 6 months (P < 0.001), respectively. At 6 months, time spent in hypoglycaemia (<70 mg/dL) and time spent in hyperglycaemia (>180 mg/dL) were reduced by 30% (2.2% +/- 0.2% vs. 3.2% +/- 0.2%; P < 0.05) and 26% (28.3% +/- 1.2% vs. 38.1% +/- 1.2%; P < 0.001), respectively. More time in auto-mode was associated with improved continuous glucose monitoring metrics, lower HbA1c and decreased glycaemic variability. Time in auto-mode declined in men after 3 months, while women maintained similar auto-mode use throughout the study. Conclusions The HCL system improved HbA1c levels and time-in-range, and decreased time spent in hypoglycaemia and hyperglycaemia at 6 months. Auto-mode use was significantly correlated with continuous glucose monitoring metrics and glycaemic outcomes.
引用
收藏
页码:583 / 589
页数:7
相关论文
共 22 条
  • [1] Technological advances shaping diabetes care
    Akturk, Halis Kaan
    Garg, Satish
    [J]. CURRENT OPINION IN ENDOCRINOLOGY DIABETES AND OBESITY, 2019, 26 (02) : 84 - 89
  • [2] INTEGRATED INSULIN PUMP AND CONTINUOUS GLUCOSE MONITORING TECHNOLOGY IN DIABETES CARE TODAY: A PERSPECTIVE OF REAL-LIFE EXPERIENCE WITH THE MINIMED™ 670G HYBRID CLOSED-LOOP SYSTEM
    Aleppo, Grazia
    Webb, Kimberly M.
    [J]. ENDOCRINE PRACTICE, 2018, 24 (07) : 684 - 692
  • [3] Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range
    Battelino, Tadej
    Danne, Thomas
    Bergenstal, Richard M.
    Amiel, Stephanie A.
    Beck, Roy
    Biester, Torben
    Bosi, Emanuele
    Buckingham, Bruce A.
    Cefalu, William T.
    Close, Kelly L.
    Cobelli, Claudio
    Dassau, Eyal
    DeVries, J. Hans
    Donaghue, Kim C.
    Dovc, Klemen
    Doyle, Francis J.
    Garg, Satish
    Grunberger, George
    Heller, Simon
    Heinemann, Lutz
    Hirsch, Irl B.
    Hovorka, Roman
    Jia, Weiping
    Kordonouri, Olga
    Kovatchev, Boris
    Kowalski, Aaron
    Laffel, Lori
    Levine, Brian
    Mayorov, Alexander
    Mathieu, Chantal
    Murphy, Helen R.
    Nimri, Revital
    Norgaard, Kirsten
    Parkin, Christopher G.
    Renard, Eric
    Rodbard, David
    Saboo, Banshi
    Schatz, Desmond
    Stoner, Keaton
    Urakami, Tatsuiko
    Weinzimer, Stuart A.
    Phillip, Moshe
    [J]. DIABETES CARE, 2019, 42 (08) : 1593 - 1603
  • [4] Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes
    Bergenstal, Richard M.
    Garg, Satish
    Weinzimer, Stuart A.
    Buckingham, Bruce A.
    Bode, Bruce W.
    Tamborlane, William V.
    Kaufman, Francine R.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (13): : 1407 - 1408
  • [5] International Consensus on Use of Continuous Glucose Monitoring
    Danne, Thomas
    Nimri, Revital
    Battelino, Tadej
    Bergenstal, Richard M.
    Close, Kelly L.
    DeVries, J. Hans
    Garg, Satish
    Heinemann, Lutz
    Hirsch, Irl
    Amiel, Stephanie A.
    Beck, Roy
    Bosi, Emanuele
    Buckingham, Bruce
    Cobelli, Claudio
    Dassau, Eyal
    Doyle, Francis J., III
    Heller, Simon
    Hovorka, Roman
    Jia, Weiping
    Jones, Tim
    Kordonouri, Olga
    Kovatchev, Boris
    Kowalski, Aaron
    Laffel, Lori
    Maahs, David
    Murphy, Helen R.
    Norgaard, Kirsten
    Parkin, Christopher G.
    Renard, Eric
    Saboo, Banshi
    Scharf, Mauro
    Tamborlane, William V.
    Weinzimer, Stuart A.
    Phillip, Moshe
    [J]. DIABETES CARE, 2017, 40 (12) : 1631 - 1640
  • [6] REAL-WORLD IMPLICATIONS OF HYBRID CLOSE LOOP (HCL) INSULIN DELIVERY SYSTEM
    Faulds, Eileen R.
    Zappe, Janet
    Dungan, Kathleen M.
    [J]. ENDOCRINE PRACTICE, 2019, 25 (05) : 477 - 484
  • [7] Safety Evaluation of the MiniMed 670G System in Children 7-13 Years of Age with Type 1 Diabetes
    Forlenza, Gregory P.
    Pinhas-Hamiel, Orit
    Liljenquist, David R.
    Shulman, Dorothy I.
    Bailey, Timothy S.
    Bode, Bruce W.
    Wood, Michael A.
    Buckingham, Bruce A.
    Kaiserman, Kevin B.
    Shin, John
    Huang, Suiying
    Lee, Scott W.
    Kaufman, Francine R.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (01) : 11 - 19
  • [8] State of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016-2018
    Foster, Nicole C.
    Beck, Roy W.
    Miller, Kellee M.
    Clements, Mark A.
    Rickels, Michael R.
    DiMeglio, Linda A.
    Maahs, David M.
    Tamborlane, William V.
    Bergenstal, Richard
    Smith, Elizabeth
    Olson, Beth A.
    Garg, Satish K.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (02) : 66 - 72
  • [9] Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 Diabetes
    Garg, Satish K.
    Weinzimer, Stuart A.
    Tamborlane, William V.
    Buckingham, Bruce A.
    Bode, Bruce W.
    Bailey, Timothy S.
    Brazg, Ronald L.
    Ilany, Jacob
    Slover, Robert H.
    Anderson, Stacey M.
    Bergenstal, Richard M.
    Grosman, Benyamin
    Roy, Anirban
    Cordero, Toni L.
    Shin, John
    Lee, Scott W.
    Kaufman, Francine R.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (03) : 155 - 163
  • [10] One Year Clinical Experience of the First Commercial Hybrid Closed-Loop System
    Lal, Rayhan A.
    Basina, Marina
    Maahs, David M.
    Hood, Korey
    Buckingham, Bruce
    Wilson, Darrell M.
    [J]. DIABETES CARE, 2019, 42 (12) : 2190 - 2196