Reduced graphene oxide coated nickel foam for stir bar sorptive extraction of benzotriazole ultraviolet absorbents from environmental water

被引:20
|
作者
Zhang, Qiulin [1 ]
You, Linna [1 ]
Chen, Beibei [1 ]
He, Man [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Minist Educ, Key Lab Analyt Chem Biol & Med, Wuhan 430072, Peoples R China
关键词
Stir bar sorptive extraction; Nickel foam; Reduced graphene oxide; Benzotriazole UV absorbents; High performance liquid chromatography; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; UV STABILIZERS; MASS SPECTROMETRY; SAMPLES; MICROEXTRACTION; NANOPARTICLES; ADSORBENT; ESTROGENS;
D O I
10.1016/j.talanta.2021.122332
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of porous carrier and coating sorbents in stir bar sorptive extraction (SBSE) contributes to the improvement of extraction efficiency and dynamics. Herein, porous nickel foam (NF) with large surface area and magnetic property was used as the carrier of stir bar. NF was added into the mixture of graphene oxide (GO) and reducing agent, and reduced graphene oxide (RGO) coating was obtained on the surface of NF substrate by in situ hydrothermal reduction. The characterization results of Fourier transform infrared spectroscopy, X-ray power-diffraction and scanning electron microscope showed that GO was partially reduced into RGO, and the RGO coating was uniformly loaded on the NF surface. The obtained RGO-NF composite was used as the stir bar coating for the analysis of six benzotriazole (BZTs) UV absorbents. The extraction efficiency was between 48 and 64% for six BZTs. RGO-NF stir bar exhibited faster adsorption/desorption kinetics than commercial polydimethylsiloxane coated stir bar (50 min vs 120/360 min) due to its porous structure and large specific surface area. On this basis, a method of RGO-NF coated stir bar sorptive extraction combined with high performance liquid chromatography (HPLC)-DAD was established for the determination of six BZTs. Under the optimized conditions, the limits of detection were 0.33-0.50 mu g/L for six target BZTs, and the linear range was 1-100 mu g/L. The proposed method merits good ability to resist matrix and was used to analyze six BZTs in environmental water samples. The recoveries of target BZTs were obtained within 83.0-112% in the spiked East Lake water and 97.0-111% in the spiked Yangtze River water, respectively.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Graphene oxide/polyethyleneglycol composite coated stir bar for sorptive extraction of fluoroquinolones from chicken muscle and liver
    Fan, Wenying
    He, Man
    Wu, Xiaoran
    Chen, Beibei
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1418 : 36 - 44
  • [2] Zirconium dioxide-reduced graphene oxide nanocomposite-coated stir-bar sorptive extraction coupled with ion mobility spectrometry for determining ethion
    Jafari, Mohammad T.
    Rezaei, Behzad
    Bahrami, Hajar
    TALANTA, 2018, 182 : 285 - 291
  • [3] Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to high performance liquid chromatography-ultraviolet detector for the determination of estrogens in environmental water samples
    Hu, Cong
    He, Man
    Chen, Beibei
    Zhong, Cheng
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1310 : 21 - 30
  • [4] Molecularly imprinted polymer -stir bar sorptive extraction of diazepam from natural water
    Sorribes-Soriano, Aitor
    Esteve-Turrillas, Francesc Albert
    Armenta, Sergio
    Herrero-Martinez, Jose Manuel
    MICROCHEMICAL JOURNAL, 2023, 186
  • [5] Polydimethylsiloxane/MIL-100(Fe) coated stir bar sorptive extraction-high performance liquid chromatography for the determination of triazines in environmental water samples
    Lei, Yun
    Chen, Beibei
    You, Linna
    He, Man
    Hu, Bin
    TALANTA, 2017, 175 : 158 - 167
  • [6] Azo-linked porous organic polymers/polydimethylsiloxane coated stir bar for extraction of benzotriazole ultraviolet absorbers from environmental water and soil samples followed by high performance liquid chromatography-diode array detection
    Wang, Zhuo
    He, Man
    Chen, Beibei
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1616 (1616)
  • [7] Imine-linked covalent organic frameworks coated stir bar sorptive extraction of non-steroidal anti-inflammatory drugs from environmental water followed by high performance liquid chromatography-ultraviolet detection
    Zang, Lijuan
    He, Man
    Wu, Zhekuan
    Chen, Beibei
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1659
  • [8] Water-compatible graphene oxide/molecularly imprinted polymer coated stir bar sorptive extraction of propranolol from urine samples followed by high performance liquid chromatography-ultraviolet detection
    Fan, Wenying
    He, Man
    You, Linna
    Zhu, Xuewei
    Chen, Beibei
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1443 : 1 - 9
  • [9] Graphene oxide-coated stir bar sorptive extraction of trace aflatoxins from soy milk followed by high performance liquid chromatography-laser-induced fluorescence detection
    Ma, Haiyan
    Ran, Congcong
    Li, Mengjiao
    Gao, Jinglin
    Wang, Xinyu
    Zhang, Lina
    Bian, Jing
    Li, Junmei
    Jiang, Ye
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2018, 35 (04): : 772 - 781
  • [10] Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to gas chromatography-flame photometric detection for the determination of organophosphorus pesticides in environmental water samples
    Xiao, Zuowei
    He, Man
    Chen, Beibei
    Hu, Bin
    TALANTA, 2016, 156 : 126 - 133