Reducing environmental pollution and fuel consumption using optimization algorithm to develop combined cooling heating and power system operation strategies

被引:42
|
作者
Li, Ling-Ling [1 ,2 ]
Liu, Yu-Wei [1 ,2 ]
Tseng, Ming-Lang [3 ,4 ]
Lin, Guo-Qian [1 ]
Ali, Mohd Helmi [5 ]
机构
[1] Hebei Univ Technol, State Key Lab Reliabil & Intelligence Elect Equip, Tianjin 300130, Peoples R China
[2] Hebei Univ Technol, Key Lab Electromagnet Field & Elect Apparat Relia, Tianjin 300130, Peoples R China
[3] Asia Univ, Inst Innovat & Circular Econ, Taichung, Taiwan
[4] China Med Univ, China Med Univ Hosp, Dept Med Res, Taichung, Taiwan
[5] Natl Univ Malaysia, Fac Econ & Management, Bangi, Malaysia
关键词
Combined cooling heating and power system; Photovoltaic generation unit; Hybrid operation strategy; System optimization; Chaos-mutation-whale optimization algorithm; PARTICLE SWARM OPTIMIZATION; CCHP SYSTEM; PARAMETER-ESTIMATION; LOCAL SEARCH; ENERGY; DESIGN; MODEL; DISPATCH; TRIGENERATION; MANAGEMENT;
D O I
10.1016/j.jclepro.2019.119082
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A combined cooling heating and power model with photovoltaic generation unit, thermal storage tank and battery is established to improve energy efficiency and reduce carbon emissions in combined cooling heating and power model for achieving cleaner production and environmental pollution reduction, and the hybrid following the electric load strategy and hybrid following the thermal load strategy are proposed based on the following the electric load strategy and following the thermal load strategy. Besides, the chaos-mutation-whale optimization algorithm is proposed to solve the models by using chaotic initialization and mutation rules into the original whale optimization algorithm. A large hotel case is used to analyze the feasibility of the proposed method. The result demonstrates the electricity import saving ratio, primary energy saving ratio and fuel consumption to cost ratio are 62.07%, 35.75% and 1.47% under the hybrid following the thermal load strategy, and the chaos-mutation-whale optimization algorithm achieves optimization in a shorter number of iterations. The performance indicators are better than the following the electric load, following the thermal load and hybrid following the thermal load strategies, indicating that environmental pollution and fuel consumption are greatly reduced by using the proposed method, which is of great significance to the realization of cleaner production and environmental sustainability. This study is carried out under ideal circumstances. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Synergistic optimal operation for a combined cooling, heating and power system with hybrid energy storage
    Yan, Yi
    Zhang, Chenghui
    Li, Ke
    Hai, Xiaopeng
    SCIENCE CHINA-INFORMATION SCIENCES, 2018, 61 (11)
  • [32] An optimization method for design and operation of combined cooling, heating, and power systems toward a smart grid
    Chen, Yi
    Luo, Yimo
    Yang, Hongxing
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (06) : 766 - 782
  • [33] An Innovative Design and Cost Optimization of a Trigeneration (Combined Cooling, Heating and Power) System
    Abbaspour, M.
    Saraei, A. R.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2014, 8 (04) : 971 - 978
  • [34] Optimization of CHCP (combined heat power and cooling) systems operation strategy using dynamic programming
    Facci, Andrea Luigi
    Andreassi, Luca
    Ubertini, Stefano
    ENERGY, 2014, 66 : 387 - 400
  • [35] A novel operation strategy based on black hole algorithm to optimize combined cooling, heating, and power-ground source heat pump system
    Deng, Yan
    Liu, Yicai
    Zeng, Rong
    Wang, Qianxu
    Li, Zheng
    Zhang, Yu
    Liang, Heng
    ENERGY, 2021, 229
  • [36] A novel off-design model to optimize combined cooling, heating and power system with hybrid chillers for different operation strategies
    Deng, Yan
    Zeng, Rong
    Liu, Yicai
    ENERGY, 2022, 239
  • [37] Multi-objective optimization of combined cooling, heating and power system integrated with solar and geothermal energies
    Ren, Fukang
    Wang, Jiangjiang
    Zhu, Sitong
    Chen, Yi
    ENERGY CONVERSION AND MANAGEMENT, 2019, 197
  • [38] Energy flow optimization method for multi-energy system oriented to combined cooling, heating and power
    Chen Lingmin
    Wu Jiekang
    Wu Fan
    Tang Huiling
    Li Changjie
    Xiong Yan
    ENERGY, 2020, 211
  • [39] Method of Optimization and Multi-criteria Evaluation of Distributed Combined Cooling Heating and Power Energy System
    Wang, Xudong
    Jiang, Ling
    Yu, Jiancheng
    Wang, Yingqiu
    Qi, Yan
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN MECHANICAL ENGINEERING AND INDUSTRIAL INFORMATICS (AMEII 2016), 2016, 73 : 615 - 621
  • [40] Dynamic analysis and operation simulation for a combined cooling heating and power system driven by geothermal energy
    Cao, Liyan
    Wang, Jiangfeng
    Yang, Yi
    Wang, Yaxiong
    Li, Hang
    Lou, Juwei
    Rao, Qiqi
    Li, Yan
    ENERGY CONVERSION AND MANAGEMENT, 2021, 228