Impact of magnetic resonance imaging on functional integrity of non-conditional cardiovascular implantable electronic devices

被引:1
作者
Dahiya, Garima [1 ]
Wetzel, Adam [2 ]
Kyvernitakis, Andreas [3 ]
Gevenosky, Loretta [3 ,4 ]
Williams, Ronald [3 ,4 ]
Shah, Moneal [3 ,4 ]
Farah, Victor [3 ]
Doyle, Mark [3 ,4 ]
Biederman, Robert W. W. [3 ,4 ]
机构
[1] Univ Minnesota, Dept Cardiovasc Dis, Minneapolis, MN USA
[2] Cleveland Clin Fdn, Radiol, 9500 Euclid Ave, Cleveland, OH 44195 USA
[3] Allegheny Gen Hosp, Cardiovasc Dis, Pittsburgh, PA 15212 USA
[4] Allegheny Gen Hosp, Ctr Cardiovasc MRI Res & Dev, Pittsburgh, PA 15212 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2021年 / 44卷 / 08期
关键词
ICD; magnetic resonance imaging; major adverse clinical events; outcomes; pacemaker; PERMANENT PACEMAKER IMPLANTATION; CARDIOVERTER-DEFIBRILLATORS; INDUSTRY VIEWPOINT; UNITED-STATES; SAFETY; TRENDS; MRI; IMPEDANCE; SOCIETY; RISKS;
D O I
10.1111/pace.14298
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cardiovascular implantable electronic devices (CIEDs) have historically restricted the use of magnetic resonance imaging (MRI) due to the potential clinical and configurational risks associated with electromagnetic interference. In this study, the authors investigated the impact of MRI on the functional integrity of non-conditional CIEDs and their clinical correlates. Methods In this prospective, observational single-center study, we enrolled patients undergoing MRI over a 5-year period. Prior to assessing the impact of MRI on CIEDs, we performed interrogations in sequential duplication to assess the intrinsic variability of devices. Subsequently, we performed interrogations immediately after MRI, and monitored changes in device parameters and clinical events. Results We completed 492 MRI studies, 58% in patients with permanent pacemakers (PPMs) and 42% with implantable cardioverter defibrillators (ICDs). Subsequent MRI exposures occurred in 15% encounters. Accounting for intrinsic variability in CIED leads, there were no significant changes in RA, RV, or LV parameters after MRI, regardless of the region imaged (thoracic vs. non-thoracic), type of CIED (PPMs vs. ICDs) and among those with serial MRIs. When ranked for % change pre- to post-MRI, the majority of RA, RV, and LV metrics for thresholds, sensing, and impedance conformed to <= 20% change from baseline. No significant clinical adverse cardiac events or effect on device microcircuitry occurred during the study. Conclusion Incorporating a novel reproducibility tactic, there were neither clinically meaningful device parameter changes nor adverse clinical events during or following MRIs, suggesting the effects of MRI on non-conditional CIED integrity are far less than previously perceived.
引用
收藏
页码:1312 / 1319
页数:8
相关论文
共 24 条
  • [1] Effects of External Electrical and Magnetic Fields on Pacemakers and Defibrillators From Engineering Principles to Clinical Practice
    Beinart, Roy
    Nazarian, Saman
    [J]. CIRCULATION, 2013, 128 (25) : 2799 - 2809
  • [2] Determining the Risks of Magnetic Resonance Imaging at 1.5 Tesla for Patients With Pacemakers and Implantable Cardioverter Defibrillators
    Cohen, Jennifer D.
    Costa, Heather S.
    Russo, Robert J.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (11) : 1631 - 1636
  • [3] Pacing impedance variability in tined steroid eluting leads
    Danilovic, D
    Ohm, OJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (07): : 1356 - 1363
  • [4] Food and drug administration perspective - Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients
    Faris, Owen P.
    Shein, Mitchell
    [J]. CIRCULATION, 2006, 114 (12) : 1232 - 1233
  • [5] Randomized trial of pacemaker and lead system for safe scanning at 1.5 Tesla
    Gimbel, J. Rod
    Bello, David
    Schmitt, Matthias
    Merkely, Bela
    Schwitter, Juerg
    Hayes, David L.
    Sommer, Torsten
    Schloss, Edward J.
    Chang, Yanping
    Willey, Sarah
    Kanal, Emanuel
    [J]. HEART RHYTHM, 2013, 10 (05) : 685 - 691
  • [6] Outcome of magnetic resonance imaging (MRI) in selected patients with implantable cardioverter defibrillators (ICDs)
    Gimbel, JR
    Kanal, E
    Schwartz, KM
    Wilkoff, BL
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (04): : 270 - 273
  • [7] Trends in Permanent Pacemaker Implantation in the United States From 1993 to 2009 Increasing Complexity of Patients and Procedures
    Greenspon, Arnold J.
    Patel, Jasmine D.
    Lau, Edmund
    Ochoa, Jorge A.
    Frisch, Daniel R.
    Ho, Reginald T.
    Pavri, Behzad B.
    Kurtz, Steven M.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (16) : 1540 - 1545
  • [8] Implantation Trends and Patient Profiles for Pacemakers and Implantable Cardioverter Defibrillators in the United States: 1993-2006
    Kurtz, Steven M.
    Ochoa, Jorge A.
    Lau, Edmund
    Shkolnikov, Yakov
    Pavri, Behzad B.
    Frisch, Daniel
    Greenspon, Arnold J.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (06): : 705 - 711
  • [9] Industry viewpoint: St. Jude Medical: Pacemakers, ICDs and MRI
    Levine, PA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (04): : 266 - 267
  • [10] The use of imaging for electrophysiological and devices procedures: a report from the first European Heart Rhythm Association Policy Conference, jointly organized with the European Association of Cardiovascular Imaging (EACVI), the Council of Cardiovascular Imaging and the European Society of Cardiac Radiology
    Lundqvist, Carina Blomstrom
    Auricchio, Angelo
    Brugada, Josep
    Boriani, Giuseppe
    Bremerich, Jens
    Angel Cabrera, Jose
    Frank, Herbert
    Gutberlet, Matthias
    Heidbuchel, Hein
    Kuck, Karl-Heinz
    Lancellotti, Patrizio
    Rademakers, Frank
    Winkels, Gerard
    Wolpert, Christian
    Vardas, Panos E.
    [J]. EUROPACE, 2013, 15 (07): : 927 - 936