Outcomes of Alternative Reservoir Placement in the Lateral Retroperitoneum During Inflatable Penile Prosthesis Placement

被引:9
作者
Loh-Doyle, Jeffrey C. [1 ]
Lin, Jeffery S. [1 ]
Doumanian, Leo R. [1 ]
Patil, Mukul B. [1 ]
Boyd, Stuart D. [1 ]
机构
[1] Univ Southern Calif, Keck Sch Med, USC Norris Comprehens Canc Ctr, USC Inst Urol, Los Angeles, CA 90007 USA
关键词
HIGH SUBMUSCULAR PLACEMENT; IMPLANTATION; COMPLICATION; COMPRESSION; BALLOONS;
D O I
10.1016/j.urology.2021.02.021
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES To describe outcomes of reservoir placement, exchange, and extraction from the lateral retroperitoneum (LR) in complex patients with a three-piece inflatable penile prosthesis (IPP). METHODS A retrospective chart review was performed on all patients that underwent placement of an IPP from 2009 to 2019. Patients with placement of the reservoir in the LR were identified. Intraoperative complications during reservoir placement, exchange, or removal, reservoir-related outcomes, and secondary device-related outcomes were collated and compared to patients who underwent traditional Space of Retzius reservoir placement. RESULTS A total of 587 men underwent primary IPP placement with 321 patients undergoing reservoir placement in the SOR and 266 in the LR. No significant differences were found in intra-operative reservoir-related outcomes (P=.272) between the 2 groups during placement, replacement, or extraction. Bowel injury occurred in 1 patient in the LR group during placement. No significant differences were found in postoperative reservoir complications (P=.534). Both groups each had one instance of patient reported bulge and pain at reservoir site (P=.6777). Two (0.6%) patients in the SOR group and 3 (1.1%) patients in the LR group had a reservoir failure or leak. There was a trend towards a lower rate of device infections in the LR group (1.9%) compared to the SOR group (4.7%) (P=.063). There were no significant differences in overall device mechanical failure rates between both groups (P=.919). CONCLUSIONS Reservoir placement in the LR is safe in patients with complex pelvic anatomy with equivalent device durability and no difference in surgical outcomes compared to standard retropubic reservoir placement. (C) 2021 Elsevier Inc.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 24 条
  • [1] Reservoir repositioning and successful thrombectomy for deep venous thrombosis secondary to compression of pelvic veins by an inflatable penile prosthesis reservoir
    Brison, Daniel
    Ilbeigi, Pedram
    Sadeghi-Nejad, Hossein
    [J]. JOURNAL OF SEXUAL MEDICINE, 2007, 4 (04) : 1185 - 1187
  • [2] High Submuscular Placement of Urologic Prosthetic Balloons and Reservoirs: 2-Year Experience and Patient-reported Outcomes
    Chung, Paul H.
    Morey, Allen F.
    Tausch, Timothy J.
    Simhan, Jay
    Scott, J. Francis
    [J]. UROLOGY, 2014, 84 (06) : 1540 - 1545
  • [3] Non-Infectious Reservoir-Related Complications During and After Penile Prosthesis Placement
    Clavell-Hernandez, Jonathan
    Shah, Anuj
    Wang, Run
    [J]. SEXUAL MEDICINE REVIEWS, 2019, 7 (03) : 521 - 529
  • [4] Severe Vascular Complication after Implantation of a Three-Piece Inflatable Penile Prosthesis
    Deho', Federico
    Henry, Gerard D.
    Marone, Enrico M.
    Sacca', Antonino
    Chiesa, Roberto
    Rigatti, Patrizio
    Montorsi, Francesco
    [J]. JOURNAL OF SEXUAL MEDICINE, 2008, 5 (12) : 2956 - 2959
  • [5] COMPLICATION OF A PENILE PROSTHESIS RESERVOIR - VENOUS COMPRESSION MASQUERADING AS A DEEP VENOUS THROMBOSIS
    FLANAGAN, MJ
    KRISCH, EB
    GERBER, WL
    [J]. JOURNAL OF UROLOGY, 1991, 146 (03) : 847 - 848
  • [6] Subcutaneous Placement of Inflatable Penile Prosthesis Reservoirs
    Garber, Bruce B.
    Bickell, Michael
    [J]. UROLOGY, 2016, 88 : 93 - 95
  • [7] The penoscrotal surgical approach for inflatable penile prosthesis placement
    Gupta, Nikhil K.
    Ring, Josh
    Trost, Landon
    Wilson, Steven K.
    Koehler, Tobias S.
    [J]. TRANSLATIONAL ANDROLOGY AND UROLOGY, 2017, 6 (04) : 628 - 638
  • [8] The Evolution of the Inflatable Penile Prosthesis Reservoir and Surgical Placement
    Hakky, Tariq
    Lentz, Aaron
    Sadeghi-Nejad, Hossein
    Khera, Mohit
    [J]. JOURNAL OF SEXUAL MEDICINE, 2015, 12 : 464 - 467
  • [9] Outcomes of lateral retroperitoneal reservoir placement of three-piece penile prosthesis in patients following radical prostatectomy
    Hartman, R. J., Jr.
    Helfand, B. T.
    McVary, K. T.
    [J]. INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 2010, 22 (04) : 279 - 283
  • [10] Reservoir Alternate Surgical Implantation Technique: Preliminary Outcomes of Initial PROPPER Study of Low Profile or Spherical Reservoir Implantation in Submuscular Location or Traditional Prevesical Space
    Karpman, Edward
    Brant, William O.
    Kansas, Bryan
    Bella, Anthony J.
    Jones, LeRoy A.
    Eisenhart, Elizabeth
    Henry, Gerard
    [J]. JOURNAL OF UROLOGY, 2015, 193 (01) : 239 - 244