Optimization and the effect of steam turbine outlet quality on the output power of a combined cycle power plant

被引:72
作者
Ganjehkaviri, A. [1 ]
Jaafar, M. N. Mohd [1 ]
Hosseini, S. E. [1 ]
机构
[1] Univ Teknol Malaysia, Dept Mech Engn, Skudai, JB, Malaysia
关键词
Combined cycle power plant; Exergoeconomic; Exergoenvironment; Steam turbine outlet quality; Optimization; Pareto frontier; EXERGOECONOMIC ANALYSIS; EXERGY ANALYSIS; MULTIOBJECTIVE OPTIMIZATION; THERMOECONOMIC OPTIMIZATION; ENVIRONMENTAL-ANALYSES; ENERGY; SYSTEM; HEAT; GAS; ALGORITHM;
D O I
10.1016/j.enconman.2014.09.042
中图分类号
O414.1 [热力学];
学科分类号
摘要
A narrow path exists to a sustainable solution which passes through careful steps of efficiency improvement (resource management) and provides environmental friendly energies. Thermal power plants are more common in many power production sites around the world. Therefore, in this current research study a comprehensive thermodynamic modeling of a combined cycle power plant with dual pressure heat recovery steam generator is presented. Since the steam turbine outlet quality is a restrictive parameter, optimization of three cases with different steam quality are conducted and discussed. In other hand, energy and exergy analysis of each components for these three different cases estimated and compared. Obtained results show that it is really important to keep the quality of the vapor at turbine outlet constant in 88% for the results to be more realistic and also optimization and data are more technically feasible and applicable. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:231 / 243
页数:13
相关论文
共 36 条
[1]   Exergoeconomic analysis and optimization of combined heat and power production: A review [J].
Abusoglu, Aysegul ;
Kanoglu, Mehmet .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (09) :2295-2308
[2]   Greenhouse gas emission and exergo-environmental analyses of a trigeneration energy system [J].
Ahmadi, Pouria ;
Rosen, Marc A. ;
Dincer, Ibrahim .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2011, 5 (06) :1540-1549
[3]   Exergy, exergoeconomic and environmental analyses and evolutionary algorithm based multi-objective optimization of combined cycle power plants [J].
Ahmadi, Pouria ;
Dincer, Ibrahim ;
Rosen, Marc A. .
ENERGY, 2011, 36 (10) :5886-5898
[4]   Thermodynamic analysis and thermoeconomic optimization of a dual pressure combined cycle power plant with a supplementary firing unit [J].
Ahmadi, Pouria ;
Dincer, Ibrahim .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (05) :2296-2308
[5]   Energy and exergy analysis of a steam power plant in Jordan [J].
Aijundi, Isam H. .
APPLIED THERMAL ENGINEERING, 2009, 29 (2-3) :324-328
[6]   Exergetic, economic and environmental (3E) analyses, and multiobjective optimization of a CO2/NH3 cascade refrigeration system [J].
Aminyavari, Mehdi ;
Najafi, Behzad ;
Shirazi, Alec ;
Rinaldi, Fabio .
APPLIED THERMAL ENGINEERING, 2014, 65 (1-2) :42-50
[7]   Thermo-economic-environmental multiobjective optimization of a gas turbine power plant with preheater using evolutionary algorithm [J].
Avval, H. Barzegar ;
Ahmadi, P. ;
Ghaffarizadeh, A. R. ;
Saidi, M. H. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2011, 35 (05) :389-403
[8]  
Bejan A., 1995, Thermal Design and Optimization
[9]   Energy-exergy analysis and modernization suggestions for a combined-cycle power plant [J].
Cihan, A ;
Hacihafizoglu, O ;
Kahveci, K .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2006, 30 (02) :115-126
[10]   A fast and elitist multiobjective genetic algorithm: NSGA-II [J].
Deb, K ;
Pratap, A ;
Agarwal, S ;
Meyarivan, T .
IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2002, 6 (02) :182-197