Heat Transfer Characteristics in a Double-Pipe Heat Exchanger Equipped with Coiled Circular Wires

被引:41
作者
Zohir, A. E. [1 ]
Habib, M. A. [2 ,3 ]
Nemitallah, M. A. [3 ]
机构
[1] Tabbin Inst Met Studies, Dept Mech Engn, Cairo, Egypt
[2] KACST Technol Innovat Ctr Carbon Capture & Segues, Dhahran, Saudi Arabia
[3] King Fahd Univ Petr & Minerals, Dept Mech Engn, Dhahran 31261, Saudi Arabia
关键词
turbulent annulus flow; heat transfer enhancement; experimental investigation; coiled wire; double-pipe heat exchanger; TRANSFER ENHANCEMENT; PRESSURE-DROP; TRANSFER AUGMENTATION; TUBE INSERTS; ROUND TUBES; FLOW; PERFORMANCE; TURBULATORS; FLUX;
D O I
10.1080/08916152.2014.915271
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental investigation has been carried out to study the enhancement in heat transfer coefficient by inserting coiled wire around the outer surface of the inner tube of the double-pipe heat exchanger. Insulated wires, with a circular cross-section of 2mm diameter, forming a coil of different pitches (p=6, 12, and 20mm), were used as turbulators. The investigation is performed for turbulent water flow in a double-pipe heat exchanger with cold water in the annulus space for both parallel and counter flows. The experiments were performed for Reynolds numbers ranging from 4,000 to 14,000. The experimental results reveal that the use of coiled circular wires leads to a considerable increase in heat transfer coefficients compared with a smooth wall tube for both parallel and counter water flows. The mean Nusselt number increases with Reynolds number and pitch. The convective heat transfer coefficient for a turbulent water flow increases for all coiled wire pitches, with the highest enhancement of about 450% for counter flow and 400% for the parallel flow. New correlations for mean relative Nusselt numbers at different coiled wire pitches are provided.
引用
收藏
页码:531 / 545
页数:15
相关论文
共 33 条
[1]   Heat transfer augmentation by coiled wire inserts during forced convection condensation of R-22 inside horizontal tubes [J].
Agrawal, KN ;
Kumar, A ;
Behabadi, MAA ;
Varma, HK .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1998, 24 (04) :635-650
[2]   TURBULENT HEAT-TRANSPORT IN CIRCULAR DUCTS WITH CIRCUMFERENTIALLY VARYING HEAT-FLUX [J].
BAUGHN, JW ;
HOFFMAN, MA ;
LAUNDER, BE ;
TAKAHASHI, RK .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1984, 106 (01) :64-70
[3]   EXPERIMENTAL INVESTIGATION OF THE AUGMENTATION OF FORCED-CONVECTION HEAT-TRANSFER IN A CIRCULAR TUBE USING SPIRAL SPRING INSERTS [J].
CHIOU, JP .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1987, 109 (02) :300-307
[4]   Investigation of heat transfer and pressure drop in a concentric heat exchanger with snail entrance [J].
Durmus, A ;
Durmus, A ;
Esen, M .
APPLIED THERMAL ENGINEERING, 2002, 22 (03) :321-332
[5]   Influence of combined non-uniform wire coil and twisted tape inserts on thermal performance characteristics [J].
Eiamsa-ard, S. ;
Nivesrangsan, P. ;
Chokphoemphun, S. ;
Promvonge, P. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (07) :850-856
[6]   Experimental study of heat transfer enhancement with wire coil inserts in laminar-transition-turbulent regimes at different Prandtl numbers [J].
García, A ;
Vicente, PG ;
Viedma, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (21-22) :4640-4651
[7]  
GNIELINSKI V, 1976, INT CHEM ENG, V16, P359
[8]   Heat transfer enhancement in a tube with equilateral triangle cross sectioned coiled wire inserts [J].
Gunes, Sibel ;
Ozceyhan, Veysel ;
Buyukalaca, Orhan .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (06) :684-691
[9]  
Holman J.P., 1984, EXPT METHODS ENG, V4th
[10]  
INABA H, 2002, T JSME B, V68, P481