Direct comparison of kinematic data collected using an electromagnetic tracking system versus a digital optical system

被引:29
作者
Hassan, Elizabeth A.
Jenkyn, Thomas R.
Dunning, Cynthia E. [1 ]
机构
[1] Univ Western Ontario, Dept Mech & Mat Engn, London, ON, Canada
[2] Fowler Kennedy Sport Med Clin, Wolf Orthopaed Biomech Lab, London, ON, Canada
关键词
motion analysis; accuracy; electromagnetic tracking; optical tracking; upperlimb kinematics;
D O I
10.1016/j.jbiomech.2006.03.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study was to quantify the dynamic accuracy of kinematics measured by a digital optical motion analysis system in a gait analysis laboratory (capture volume approximately 20 m(3)) compared to a standard range direct-current electromagnetic (EM) tracking device (capture volume approximately 1 m(3)). This is a subset of a larger effort to establish an appropriate marker set for the optical system to quantify upperlimb kinematics simultaneously with gait, in comparison to previous studies of isolated upperlimb movements that have employed EM tracking devices. Rigid clusters of spherical reflective markers and EM sensors were attached to a mechanical articulator that mimicked three-dimensional joint rotations, similar to the elbow. As the articulator was moved through known ranges of motion (i.e. gold standard), kinematic data were collected simultaneously using both tracking systems. Both systems were tended to underestimate the range of motion; however, the application of post hoe smoothing and least-squares correction algorithms reduced these effects. When smoothing and correction algorithms were used, the magnitude of the mean difference between the gold standard and either the EM or optical system did not exceed 2 degrees for any of the compound motions performed. This level of agreement suggests that the measurements obtained from either system are clinically comparable, provided appropriate smoothing and correction algorithms are employed. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:930 / 935
页数:6
相关论文
共 19 条
[1]   LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Accuracy of an electromagnetic measurement device and application to the measurement and description of knee joint motion [J].
Bull, AMJ ;
Berkshire, FH ;
Amis, AA .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1998, 212 (H5) :347-355
[4]   A PROCEDURE FOR DETERMINING RIGID-BODY TRANSFORMATION PARAMETERS [J].
CHALLIS, JH .
JOURNAL OF BIOMECHANICS, 1995, 28 (06) :733-737
[5]  
Chen XX, 2003, COMPUT SYST SCI ENG, V18, P3
[6]   A SOLIDIFICATION PROCEDURE TO FACILITATE KINEMATIC ANALYSES BASED ON VIDEO SYSTEM DATA [J].
CHEZE, L ;
FREGLY, BJ ;
DIMNET, J .
JOURNAL OF BIOMECHANICS, 1995, 28 (07) :879-884
[7]   Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysis [J].
Day, JS ;
Dumas, GA ;
Murdoch, DJ .
JOURNAL OF BIOMECHANICS, 1998, 31 (10) :957-961
[8]   A PROCEDURE TO VALIDATE 3-DIMENSIONAL MOTION ASSESSMENT SYSTEMS [J].
DELUZIO, KJ ;
WYSS, UP ;
LI, JA ;
COSTIGAN, PA .
JOURNAL OF BIOMECHANICS, 1993, 26 (06) :753-759
[9]  
Dorociak R.D., 1995, Gait and Posture, V3, P88, DOI DOI 10.1016/0966-6362(95)93468-R
[10]   Assessment of screw displacement axis accuracy and repeatability for joint kinematic description using an electromagnetic tracking device [J].
Duck, TR ;
Ferreira, LM ;
King, GJW ;
Johnson, JA .
JOURNAL OF BIOMECHANICS, 2004, 37 (01) :163-167