Combination of flow injection with capillary electrophoresis. Part 3. On-line sorption column preconcentration capillary electrophoresis system

被引:57
作者
Chen, HW [1 ]
Fang, ZL [1 ]
机构
[1] Northeastern Univ, Dept Chem, Flow Infect Anal Res Ctr, Shenyang 110006, Peoples R China
关键词
flow injection; capillary electrophoresis; preconcentration; sorbent extraction; pseudoephedrine;
D O I
10.1016/S0003-2670(97)00499-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A combined flow injection (FI)-capillary electrophoresis (CE) system with a split-flow interface reported previously was used for on-line preconcentration of pseudoephedrine by solid phase extraction on a micro-column packed with C-18 Aqueous samples were loaded on the column at 1.0 mi min(-1) for 90 s and eluted by a mixed eluent of 40% 62.5 mM acetate buffer (pH 4.0) and 60% acetonitrile at 0.2 mi min(-1). A zone-sampling approach was employed to sample 45 mu l of the most concentrated zone of the eluate, which was injected into the FI-CE split-flow interface using a phosphate buffer carrier, with a 25 mu l water zone preceding the sampled eluate zone to achieve enhanced field amplification effects. Sensitivity enhancements of 60 fold (180 fold with 4 min sample loading) were thus achieved with a sample throughput of 9 h(-1) and 4.7% relative standard deviations (n = 10, 2 mu g ml(-1) pseudoephedrine) for peak area evaluation, without significant degradation of column efficiency. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:135 / 143
页数:9
相关论文
共 16 条
[1]   SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF PSEUDOEPHEDRINE IN PLASMA AND URINE [J].
BRENDEL, E ;
MEINEKE, I ;
HENNE, EM ;
ZSCHUNKE, M ;
DEMEY, C .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 426 (02) :406-411
[2]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[3]   FIELD AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :141-152
[4]   SAMPLE STACKING OF AN EXTREMELY LARGE INJECTION VOLUME IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1046-1050
[5]   SWITCHING VALVE WITH INTERNAL MICRO PRECOLUMN FOR ONLINE SAMPLE ENRICHMENT IN CAPILLARY ZONE ELECTROPHORESIS [J].
DEBETS, AJJ ;
MAZEREEUW, M ;
VOOGT, WH ;
VANIPEREN, DJ ;
LINGEMAN, H ;
HUPE, KP ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :151-158
[6]   HIGH-EFFICIENCY LOW SAMPLE CONSUMPTION ONLINE ION-EXCHANGE PRE-CONCENTRATION SYSTEM FOR FLOW-INJECTION FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
WELZ, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (06) :543-546
[7]   Combination of flow injection with capillary electrophoresis .1. The basic system [J].
Fang, ZL ;
Liu, ZS ;
Shen, Q .
ANALYTICA CHIMICA ACTA, 1997, 346 (02) :135-143
[8]   New interface for coupling flow-injection and capillary electrophoresis [J].
Kuban, P ;
Engstrom, A ;
Olsson, JC ;
Thorsen, G ;
Tryzell, R ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 1997, 337 (02) :117-124
[9]   SPECIATION OF SELENIUM AND ARSENIC COMPOUNDS IN NATURAL-WATERS BY CAPILLARY ZONE ELECTROPHORESIS AFTER ON-COLUMN PRECONCENTRATION WITH FIELD-AMPLIFIED INJECTION [J].
LI, K ;
LI, SFY .
ANALYST, 1995, 120 (02) :361-366
[10]   Combination of flow injection with capillary electrophoresis .2. Chiral separation of intermediate enantiomers in chloramphenicol synthesis [J].
Liu, ZS ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1997, 353 (2-3) :199-205