Simultaneous measurement of two parameters of the spherical lens by low-coherence interferometry

被引:0
|
作者
Sun, Ying [1 ]
Nomura, Takanori [2 ]
机构
[1] Wakayama Univ, Grad Sch Syst Engn, 930 Sakaedani, Wakayanma, Japan
[2] Wakayama Univ, Fac Syst Engn, 930 Sakaedani, Wakayanma, Japan
来源
OPTICAL DESIGN AND TESTING X | 2020年 / 11548卷
关键词
shape measurement; low-coherence interferometry;
D O I
10.1117/12.2573173
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To measure different parameters of a spherical lens simultaneously, a method by low-coherence interferometry with a low temporal coherent light source is proposed. This proposed method can obtain both the radius of curvature and the central thickness of a spherical lens in a single optical system. Owing to the property of low temporal coherence, the contrast of interference fringe pattern, hologram, varies with the optical path difference of an object beam and a reference beam. This enables the central thickness of the test lens to acquire with a Michelson interferometer. Simultaneously, the spherical shape of the test lens, namely the radius of curvature, can be obtained from a hologram which contains information of the wavefront curvature from the reflected beam of the spherical surface of the test lens.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] High-speed simultaneous measurement of refractive index and thickness of transparent plates by low-coherence interferometry and confocal optics
    Ohmi, M
    Nishi, H
    Konishi, Y
    Yamada, Y
    Haruna, M
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (08) : 1531 - 1535
  • [42] Low-coherence interferometer system for the simultaneous measurement of refractive index and thickness
    Maruyama, H
    Inoue, S
    Mitsuyama, T
    Ohmi, M
    Haruna, M
    APPLIED OPTICS, 2002, 41 (07) : 1315 - 1322
  • [43] Low-coherence spectral interferometry with a Michelson interferometer applied to dispersion measurement of a two-mode optical fiber
    Hlubina, P
    PHOTONICS, DEVICES,AND SYSTEMS, 2000, 4016 : 8 - 13
  • [44] Biometric Parameters in Different Stages of Primary Angle Closure Using Low-Coherence Interferometry
    Yazdani, Shahin
    Akbarian, Shadi
    Pakravan, Mohammad
    Doozandeh, Azadeh
    Afrouzifar, Mohsen
    OPTOMETRY AND VISION SCIENCE, 2015, 92 (03) : 343 - 349
  • [45] Absolute measurement of gauge block without wringing using tandem low-coherence interferometry
    Winarno, Agustinus
    Takahashi, Satoru
    Hirai, Akiko
    Takamasu, Kiyoshi
    Matsumoto, Hirokazu
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (12)
  • [46] Refractive index and dispersion measurement using low-coherence interferometry with broadband confocal scanning
    Francis, Daniel
    Ford, Helen D.
    Tatam, Ralph P.
    OPTICAL SENSING AND DETECTION V, 2018, 10680
  • [47] Label-free measurement of microbicidal gel thickness using low-coherence interferometry
    Braun, Kelly E.
    Boyer, Jeffrey D.
    Henderson, Marcus H.
    Katz, David F.
    Wax, Adam
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (02)
  • [48] Depth-resolved measurement of ocular fundus pulsations by low-coherence tissue interferometry
    Dragostinoff, Nikolaus
    Werkmeister, Rene M.
    Groeschl, Martin
    Schmetterer, Leopold
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (05)
  • [49] Measurement of the Pulsatile Movement of Ocular Tissues With Fourier-Domain Low-Coherence Interferometry
    Singh, K.
    Dion, C.
    Costantino, S.
    Wajszilber, M.
    Ozaki, T.
    Lesk, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [50] Dispersion-insensitive measurement of thickness and group refractive index by low-coherence interferometry
    Murphy, DF
    Flavin, DA
    APPLIED OPTICS, 2000, 39 (25) : 4607 - 4615